Impact of DG Configuration on Maximum Use of Load Supply Capability in Distribution Power Systems
Traditional distributed generators (DGs) planning methods take network loss minimization as the main objective to optimize DG sites in feeders. The use of load supply capability (LSC) in DG planning will precisely answer the questions how many DGs should be integrated, which transformer they should...
Saved in:
Main Authors: | , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Wiley
2014-01-01
|
Series: | Journal of Applied Mathematics |
Online Access: | http://dx.doi.org/10.1155/2014/136726 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
_version_ | 1832567243737661440 |
---|---|
author | Hong Liu Yinchang Guo Shaoyun Ge Mingxin Zhao |
author_facet | Hong Liu Yinchang Guo Shaoyun Ge Mingxin Zhao |
author_sort | Hong Liu |
collection | DOAJ |
description | Traditional distributed generators (DGs) planning methods take network loss minimization as the main objective to optimize DG sites in feeders. The use of load supply capability (LSC) in DG planning will precisely answer the questions how many DGs should be integrated, which transformer they should be connected to, and which type of DGs should be adopted. The main work of this paper is to analyze the impact of DGs on LSC so as to answer the three key questions. It resolves the planning problem through three steps: (i) two LSC models considering DGs’ access are developed, in which two different transfer strategies are considered: direct load transfer and indirect load transfer; (ii) the method of combined simple method and point estimate method is proposed. At last, based on a base case, when the configuration of DGs is changing, the impact of DGs on system LSC is studied. After the case study, the conclusion concerning the impact of load transfer strategy, DG capacities, and DG types on LSC is reached. |
format | Article |
id | doaj-art-97e677cc395a43418d8e49bff84d0829 |
institution | Kabale University |
issn | 1110-757X 1687-0042 |
language | English |
publishDate | 2014-01-01 |
publisher | Wiley |
record_format | Article |
series | Journal of Applied Mathematics |
spelling | doaj-art-97e677cc395a43418d8e49bff84d08292025-02-03T01:01:59ZengWileyJournal of Applied Mathematics1110-757X1687-00422014-01-01201410.1155/2014/136726136726Impact of DG Configuration on Maximum Use of Load Supply Capability in Distribution Power SystemsHong Liu0Yinchang Guo1Shaoyun Ge2Mingxin Zhao3Key Laboratory of Smart Grid, Tianjin University, Ministry of Education, Tianjin 300072, ChinaKey Laboratory of Smart Grid, Tianjin University, Ministry of Education, Tianjin 300072, ChinaKey Laboratory of Smart Grid, Tianjin University, Ministry of Education, Tianjin 300072, ChinaChina Electric Power Research Institute, Beijing 100192, ChinaTraditional distributed generators (DGs) planning methods take network loss minimization as the main objective to optimize DG sites in feeders. The use of load supply capability (LSC) in DG planning will precisely answer the questions how many DGs should be integrated, which transformer they should be connected to, and which type of DGs should be adopted. The main work of this paper is to analyze the impact of DGs on LSC so as to answer the three key questions. It resolves the planning problem through three steps: (i) two LSC models considering DGs’ access are developed, in which two different transfer strategies are considered: direct load transfer and indirect load transfer; (ii) the method of combined simple method and point estimate method is proposed. At last, based on a base case, when the configuration of DGs is changing, the impact of DGs on system LSC is studied. After the case study, the conclusion concerning the impact of load transfer strategy, DG capacities, and DG types on LSC is reached.http://dx.doi.org/10.1155/2014/136726 |
spellingShingle | Hong Liu Yinchang Guo Shaoyun Ge Mingxin Zhao Impact of DG Configuration on Maximum Use of Load Supply Capability in Distribution Power Systems Journal of Applied Mathematics |
title | Impact of DG Configuration on Maximum Use of Load Supply Capability in Distribution Power Systems |
title_full | Impact of DG Configuration on Maximum Use of Load Supply Capability in Distribution Power Systems |
title_fullStr | Impact of DG Configuration on Maximum Use of Load Supply Capability in Distribution Power Systems |
title_full_unstemmed | Impact of DG Configuration on Maximum Use of Load Supply Capability in Distribution Power Systems |
title_short | Impact of DG Configuration on Maximum Use of Load Supply Capability in Distribution Power Systems |
title_sort | impact of dg configuration on maximum use of load supply capability in distribution power systems |
url | http://dx.doi.org/10.1155/2014/136726 |
work_keys_str_mv | AT hongliu impactofdgconfigurationonmaximumuseofloadsupplycapabilityindistributionpowersystems AT yinchangguo impactofdgconfigurationonmaximumuseofloadsupplycapabilityindistributionpowersystems AT shaoyunge impactofdgconfigurationonmaximumuseofloadsupplycapabilityindistributionpowersystems AT mingxinzhao impactofdgconfigurationonmaximumuseofloadsupplycapabilityindistributionpowersystems |