Optimization of the Operation of Groundwater Intakes Using Two-Column Wells

The average number of wells at a typical water intake is 30–40; while the power of the submersible pump is usually 32–40 kW; which means that only at one well water intake the power consumption of electric pumping equipment during the hours of greatest water consumption can reach 900–1600 kW. In the...

Full description

Saved in:
Bibliographic Details
Main Authors: V. V. Ivashechkin, J. A. Medvedeva
Format: Article
Language:Russian
Published: Belarusian National Technical University 2022-10-01
Series:Известия высших учебных заведений и энергетических объединенний СНГ: Энергетика
Subjects:
Online Access:https://energy.bntu.by/jour/article/view/2202
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1832557322288758784
author V. V. Ivashechkin
J. A. Medvedeva
author_facet V. V. Ivashechkin
J. A. Medvedeva
author_sort V. V. Ivashechkin
collection DOAJ
description The average number of wells at a typical water intake is 30–40; while the power of the submersible pump is usually 32–40 kW; which means that only at one well water intake the power consumption of electric pumping equipment during the hours of greatest water consumption can reach 900–1600 kW. In the structure of operating costs of well water intakes; the share of electricity costs reaches 85 %. Taking into account the requirements for reducing costs and water tariffs of housing and communal services enterprises as well as of water utilities; energy saving is an urgent task. The article considers the optimization of the operation of groundwater intakes with uneven water supply due to the use of two-column water intake wells instead of typical single-column ones. It is shown that the use of powerful pumps in single-column wells of such water intakes causes a sharp decrease in the dynamic water level in the borehole. On the one hand; this provokes the formation of colmating deposits in the filters due to their aeration; reduces the specific flow rate of the well and shortens the intervals between regenerations. On the other hand; this increases the geometric pressure of submersible pumps and energy consumption for lifting water. The theoretical foundations of determining the supply of pumps installed in single- and two-column water intake wells supplying water to the pressure filter of the water treatment plant are considered. An example of a comparative analysis of the operation of one working well with one powerful pump as part of a water intake of two single-column wells (working and reserve) to cover the entire water supply schedule and two two-column working wells containing one less powerful pump in each column is given. The energy efficiency of these pumping systems is investigated. As a result of calculations; it was found that when combining the operation of pumps of two-column wells during periods of peak; main and partial loads; the annual energy savings will amount to 33 %.
format Article
id doaj-art-95214b39cb6f4a1fad6c97c102ba7182
institution Kabale University
issn 1029-7448
2414-0341
language Russian
publishDate 2022-10-01
publisher Belarusian National Technical University
record_format Article
series Известия высших учебных заведений и энергетических объединенний СНГ: Энергетика
spelling doaj-art-95214b39cb6f4a1fad6c97c102ba71822025-02-03T05:20:03ZrusBelarusian National Technical UniversityИзвестия высших учебных заведений и энергетических объединенний СНГ: Энергетика1029-74482414-03412022-10-0165545146210.21122/1029-7448-2023-65-5-451-4621825Optimization of the Operation of Groundwater Intakes Using Two-Column WellsV. V. Ivashechkin0J. A. Medvedeva1Belarusian National Technical UniversityBelarusian National Technical UniversityThe average number of wells at a typical water intake is 30–40; while the power of the submersible pump is usually 32–40 kW; which means that only at one well water intake the power consumption of electric pumping equipment during the hours of greatest water consumption can reach 900–1600 kW. In the structure of operating costs of well water intakes; the share of electricity costs reaches 85 %. Taking into account the requirements for reducing costs and water tariffs of housing and communal services enterprises as well as of water utilities; energy saving is an urgent task. The article considers the optimization of the operation of groundwater intakes with uneven water supply due to the use of two-column water intake wells instead of typical single-column ones. It is shown that the use of powerful pumps in single-column wells of such water intakes causes a sharp decrease in the dynamic water level in the borehole. On the one hand; this provokes the formation of colmating deposits in the filters due to their aeration; reduces the specific flow rate of the well and shortens the intervals between regenerations. On the other hand; this increases the geometric pressure of submersible pumps and energy consumption for lifting water. The theoretical foundations of determining the supply of pumps installed in single- and two-column water intake wells supplying water to the pressure filter of the water treatment plant are considered. An example of a comparative analysis of the operation of one working well with one powerful pump as part of a water intake of two single-column wells (working and reserve) to cover the entire water supply schedule and two two-column working wells containing one less powerful pump in each column is given. The energy efficiency of these pumping systems is investigated. As a result of calculations; it was found that when combining the operation of pumps of two-column wells during periods of peak; main and partial loads; the annual energy savings will amount to 33 %.https://energy.bntu.by/jour/article/view/2202water supplywellconsumerpumpcolmatationwater intakepower consumptionenergy efficiency
spellingShingle V. V. Ivashechkin
J. A. Medvedeva
Optimization of the Operation of Groundwater Intakes Using Two-Column Wells
Известия высших учебных заведений и энергетических объединенний СНГ: Энергетика
water supply
well
consumer
pump
colmatation
water intake
power consumption
energy efficiency
title Optimization of the Operation of Groundwater Intakes Using Two-Column Wells
title_full Optimization of the Operation of Groundwater Intakes Using Two-Column Wells
title_fullStr Optimization of the Operation of Groundwater Intakes Using Two-Column Wells
title_full_unstemmed Optimization of the Operation of Groundwater Intakes Using Two-Column Wells
title_short Optimization of the Operation of Groundwater Intakes Using Two-Column Wells
title_sort optimization of the operation of groundwater intakes using two column wells
topic water supply
well
consumer
pump
colmatation
water intake
power consumption
energy efficiency
url https://energy.bntu.by/jour/article/view/2202
work_keys_str_mv AT vvivashechkin optimizationoftheoperationofgroundwaterintakesusingtwocolumnwells
AT jamedvedeva optimizationoftheoperationofgroundwaterintakesusingtwocolumnwells