Hollow Fibre-Supported Liquid Membrane for the Determination of Sulfonamide Residues in Egg Samples

In this study, a three-phase hollow fibre-supported liquid membrane (HF-SLM) technique incorporated with high-performance liquid chromatography (HPLC) coupled with diode array detection (DAD) was developed for the extraction, clean-up, and determination of fifteen sulfonamide residues in chicken egg...

Full description

Saved in:
Bibliographic Details
Main Authors: Eskinder Teklu Bekele, S. Dube, M. M. Nindi
Format: Article
Language:English
Published: Wiley 2022-01-01
Series:Journal of Chemistry
Online Access:http://dx.doi.org/10.1155/2022/3918970
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1832551687928152064
author Eskinder Teklu Bekele
S. Dube
M. M. Nindi
author_facet Eskinder Teklu Bekele
S. Dube
M. M. Nindi
author_sort Eskinder Teklu Bekele
collection DOAJ
description In this study, a three-phase hollow fibre-supported liquid membrane (HF-SLM) technique incorporated with high-performance liquid chromatography (HPLC) coupled with diode array detection (DAD) was developed for the extraction, clean-up, and determination of fifteen sulfonamide residues in chicken egg samples. The residues were extracted from the 5 mL sample solution of pH 2.5 into a thin layer of organic phase (1-octanol with 10% TOPO) immobilised in hollow fibre pores and then back-extracted into approximately 6 μL of aqueous phase (pH 13) located in the lumen of the hollow fibre. After extraction, 6 μL of the acceptor phase was injected into an HPLC instrument for subsequent analysis. Under optimum conditions, the limit of detection (LOD) and limit of quantification (LOQ) values ranged from 0.8–7.9 μg·kg−1 and from 2.4–21.0 μg·kg−1, respectively, linearity in the range of 5 1 000 μg·kg−1, and intra- and inter-day precision (%RSD) values at three concentration levels (50, 100, and 500 μg·L−1) ranged from 6.2–15.7%, 7.3–15.0%, and 7.3–14.6%; and 6.4–17.4%, 4.3–16.2%, and 8.3–16.5%, respectively, were obtained. The accuracy of the method, expressed as percentage recovery, was in the range of 71.0–98.7%, with corresponding %RSD (n = 6) values ranging from 1.9–9.9% being obtained. The developed method provided enrichment factors in the range of 17.1 to 541.4. The applicability of the proposed method was also evaluated by analysing egg samples, which were randomly collected from local supermarkets located in Gauteng Province, South Africa. The results obtained revealed that the developed method has the potential to be used as an alternative method for the determination of sulfonamide residues in egg and related complex samples.
format Article
id doaj-art-941186d88bf34991b0ffbcdc3f6a13bb
institution Kabale University
issn 2090-9071
language English
publishDate 2022-01-01
publisher Wiley
record_format Article
series Journal of Chemistry
spelling doaj-art-941186d88bf34991b0ffbcdc3f6a13bb2025-02-03T06:00:55ZengWileyJournal of Chemistry2090-90712022-01-01202210.1155/2022/3918970Hollow Fibre-Supported Liquid Membrane for the Determination of Sulfonamide Residues in Egg SamplesEskinder Teklu Bekele0S. Dube1M. M. Nindi2Department of ChemistryDepartment of ChemistryInstitute for Nanotechnology and Water Sustainability (iNanoWS)In this study, a three-phase hollow fibre-supported liquid membrane (HF-SLM) technique incorporated with high-performance liquid chromatography (HPLC) coupled with diode array detection (DAD) was developed for the extraction, clean-up, and determination of fifteen sulfonamide residues in chicken egg samples. The residues were extracted from the 5 mL sample solution of pH 2.5 into a thin layer of organic phase (1-octanol with 10% TOPO) immobilised in hollow fibre pores and then back-extracted into approximately 6 μL of aqueous phase (pH 13) located in the lumen of the hollow fibre. After extraction, 6 μL of the acceptor phase was injected into an HPLC instrument for subsequent analysis. Under optimum conditions, the limit of detection (LOD) and limit of quantification (LOQ) values ranged from 0.8–7.9 μg·kg−1 and from 2.4–21.0 μg·kg−1, respectively, linearity in the range of 5 1 000 μg·kg−1, and intra- and inter-day precision (%RSD) values at three concentration levels (50, 100, and 500 μg·L−1) ranged from 6.2–15.7%, 7.3–15.0%, and 7.3–14.6%; and 6.4–17.4%, 4.3–16.2%, and 8.3–16.5%, respectively, were obtained. The accuracy of the method, expressed as percentage recovery, was in the range of 71.0–98.7%, with corresponding %RSD (n = 6) values ranging from 1.9–9.9% being obtained. The developed method provided enrichment factors in the range of 17.1 to 541.4. The applicability of the proposed method was also evaluated by analysing egg samples, which were randomly collected from local supermarkets located in Gauteng Province, South Africa. The results obtained revealed that the developed method has the potential to be used as an alternative method for the determination of sulfonamide residues in egg and related complex samples.http://dx.doi.org/10.1155/2022/3918970
spellingShingle Eskinder Teklu Bekele
S. Dube
M. M. Nindi
Hollow Fibre-Supported Liquid Membrane for the Determination of Sulfonamide Residues in Egg Samples
Journal of Chemistry
title Hollow Fibre-Supported Liquid Membrane for the Determination of Sulfonamide Residues in Egg Samples
title_full Hollow Fibre-Supported Liquid Membrane for the Determination of Sulfonamide Residues in Egg Samples
title_fullStr Hollow Fibre-Supported Liquid Membrane for the Determination of Sulfonamide Residues in Egg Samples
title_full_unstemmed Hollow Fibre-Supported Liquid Membrane for the Determination of Sulfonamide Residues in Egg Samples
title_short Hollow Fibre-Supported Liquid Membrane for the Determination of Sulfonamide Residues in Egg Samples
title_sort hollow fibre supported liquid membrane for the determination of sulfonamide residues in egg samples
url http://dx.doi.org/10.1155/2022/3918970
work_keys_str_mv AT eskinderteklubekele hollowfibresupportedliquidmembraneforthedeterminationofsulfonamideresiduesineggsamples
AT sdube hollowfibresupportedliquidmembraneforthedeterminationofsulfonamideresiduesineggsamples
AT mmnindi hollowfibresupportedliquidmembraneforthedeterminationofsulfonamideresiduesineggsamples