Acoustic spectra processing for the determination of cavitation threshold in a high-frequency sonoreactor in water and PEG mixtures from 1 to 54 mPa.s

Ultrasound-induced cavitation, especially its stable and inertial regimes, plays a critical role in sonochemical processes. Thus, finding the power thresholds differentiating the appearance of stable cavitation and then transient cavitation, is essential for sonoreactor characterization since this k...

Full description

Saved in:
Bibliographic Details
Main Authors: V. Avramovic, L. Hallez, C. Inserra, J-Y Hihn
Format: Article
Language:English
Published: Elsevier 2025-08-01
Series:Ultrasonics Sonochemistry
Subjects:
Online Access:http://www.sciencedirect.com/science/article/pii/S1350417725001671
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1849691813255839744
author V. Avramovic
L. Hallez
C. Inserra
J-Y Hihn
author_facet V. Avramovic
L. Hallez
C. Inserra
J-Y Hihn
author_sort V. Avramovic
collection DOAJ
description Ultrasound-induced cavitation, especially its stable and inertial regimes, plays a critical role in sonochemical processes. Thus, finding the power thresholds differentiating the appearance of stable cavitation and then transient cavitation, is essential for sonoreactor characterization since this knowledge allows the relevant choice of operating parameters leading to the expected sonochemical effects. However, this concept is difficult to grasp and often applied with complex techniques difficult to implement and highly “system dependent”. The study of sonochemical activity and efficiency in a high frequency reactor (575 kHz) provides an opportunity to take an interest in the step-by-step implementation of a hydrophone measurement, from selection of the device to recording procedures, and especially signal processing with selection and extraction of the two most relevant probes: 3F0/2 magnitudes useful for detecting stable cavitation and cumulative integration of broadband noise and its interpretation (slope discontinuity) to get an indication of transient cavitation appearance. An original result of this work is that this technique appears to be much more reliable and sensitive than chemical techniques when media are very viscous, remaining relevant beyond the limits of sonochemiluminescence and dosimetry techniques. This is interesting because it makes it possible to link evolution of the change thresholds of cavitation state (from absence of cavitation to stable cavitation, then transient cavitation) with an increase in viscosity. As expected, these thresholds increase, from 0.25 W- stable cavitation − and 2 W – inertial cavitation − in water up to 6 W for stable cavitation and an absence of inertial cavitation at 54 mPa.s, as it is necessary to apply more power to achieve cavitation in high viscous media. This range of magnitude of viscosity used in this study is relevant for specific applications, such as ultrasonic cleaning lines involving cleaning solutions and all scientific issues dealing with deep eutectic solvants (DES) for electropolishing or leaching processes in metal recovery. A constant monitoring by measuring regularly these parameters ensures that cleaning or treatment lines are running at constant efficiency and helps to identify critical breakdowns. Finally, what is remarkable is that the stable cavitation threshold seems to be directly proportional to the acoustic field (linear dependence of the stable cavitation threshold) if the latter is expressed in pressure, providing new challenges for acoustic fields modelling.
format Article
id doaj-art-90e2cf18a47144898523419fe7f4b76d
institution DOAJ
issn 1350-4177
language English
publishDate 2025-08-01
publisher Elsevier
record_format Article
series Ultrasonics Sonochemistry
spelling doaj-art-90e2cf18a47144898523419fe7f4b76d2025-08-20T03:20:55ZengElsevierUltrasonics Sonochemistry1350-41772025-08-0111910738810.1016/j.ultsonch.2025.107388Acoustic spectra processing for the determination of cavitation threshold in a high-frequency sonoreactor in water and PEG mixtures from 1 to 54 mPa.sV. Avramovic0L. Hallez1C. Inserra2J-Y Hihn3Université Marie et Louis Pasteur, CNRS, Institut UTINAM UMR 6213, F-25000 Besançon, FranceUniversité Marie et Louis Pasteur, CNRS, Institut UTINAM UMR 6213, F-25000 Besançon, FranceUniv Lyon, Université Claude Bernard Lyon 1, Centre Léon Bérard, INSERM, UMR 1032, LabTAU, F-69003 Lyon, FranceUniversité Marie et Louis Pasteur, CNRS, Institut UTINAM UMR 6213, F-25000 Besançon, France; Corresponding author.Ultrasound-induced cavitation, especially its stable and inertial regimes, plays a critical role in sonochemical processes. Thus, finding the power thresholds differentiating the appearance of stable cavitation and then transient cavitation, is essential for sonoreactor characterization since this knowledge allows the relevant choice of operating parameters leading to the expected sonochemical effects. However, this concept is difficult to grasp and often applied with complex techniques difficult to implement and highly “system dependent”. The study of sonochemical activity and efficiency in a high frequency reactor (575 kHz) provides an opportunity to take an interest in the step-by-step implementation of a hydrophone measurement, from selection of the device to recording procedures, and especially signal processing with selection and extraction of the two most relevant probes: 3F0/2 magnitudes useful for detecting stable cavitation and cumulative integration of broadband noise and its interpretation (slope discontinuity) to get an indication of transient cavitation appearance. An original result of this work is that this technique appears to be much more reliable and sensitive than chemical techniques when media are very viscous, remaining relevant beyond the limits of sonochemiluminescence and dosimetry techniques. This is interesting because it makes it possible to link evolution of the change thresholds of cavitation state (from absence of cavitation to stable cavitation, then transient cavitation) with an increase in viscosity. As expected, these thresholds increase, from 0.25 W- stable cavitation − and 2 W – inertial cavitation − in water up to 6 W for stable cavitation and an absence of inertial cavitation at 54 mPa.s, as it is necessary to apply more power to achieve cavitation in high viscous media. This range of magnitude of viscosity used in this study is relevant for specific applications, such as ultrasonic cleaning lines involving cleaning solutions and all scientific issues dealing with deep eutectic solvants (DES) for electropolishing or leaching processes in metal recovery. A constant monitoring by measuring regularly these parameters ensures that cleaning or treatment lines are running at constant efficiency and helps to identify critical breakdowns. Finally, what is remarkable is that the stable cavitation threshold seems to be directly proportional to the acoustic field (linear dependence of the stable cavitation threshold) if the latter is expressed in pressure, providing new challenges for acoustic fields modelling.http://www.sciencedirect.com/science/article/pii/S1350417725001671HydrophoneDosimetryAcoustic cavitationStable cavitationTransient cavitationViscous media
spellingShingle V. Avramovic
L. Hallez
C. Inserra
J-Y Hihn
Acoustic spectra processing for the determination of cavitation threshold in a high-frequency sonoreactor in water and PEG mixtures from 1 to 54 mPa.s
Ultrasonics Sonochemistry
Hydrophone
Dosimetry
Acoustic cavitation
Stable cavitation
Transient cavitation
Viscous media
title Acoustic spectra processing for the determination of cavitation threshold in a high-frequency sonoreactor in water and PEG mixtures from 1 to 54 mPa.s
title_full Acoustic spectra processing for the determination of cavitation threshold in a high-frequency sonoreactor in water and PEG mixtures from 1 to 54 mPa.s
title_fullStr Acoustic spectra processing for the determination of cavitation threshold in a high-frequency sonoreactor in water and PEG mixtures from 1 to 54 mPa.s
title_full_unstemmed Acoustic spectra processing for the determination of cavitation threshold in a high-frequency sonoreactor in water and PEG mixtures from 1 to 54 mPa.s
title_short Acoustic spectra processing for the determination of cavitation threshold in a high-frequency sonoreactor in water and PEG mixtures from 1 to 54 mPa.s
title_sort acoustic spectra processing for the determination of cavitation threshold in a high frequency sonoreactor in water and peg mixtures from 1 to 54 mpa s
topic Hydrophone
Dosimetry
Acoustic cavitation
Stable cavitation
Transient cavitation
Viscous media
url http://www.sciencedirect.com/science/article/pii/S1350417725001671
work_keys_str_mv AT vavramovic acousticspectraprocessingforthedeterminationofcavitationthresholdinahighfrequencysonoreactorinwaterandpegmixturesfrom1to54mpas
AT lhallez acousticspectraprocessingforthedeterminationofcavitationthresholdinahighfrequencysonoreactorinwaterandpegmixturesfrom1to54mpas
AT cinserra acousticspectraprocessingforthedeterminationofcavitationthresholdinahighfrequencysonoreactorinwaterandpegmixturesfrom1to54mpas
AT jyhihn acousticspectraprocessingforthedeterminationofcavitationthresholdinahighfrequencysonoreactorinwaterandpegmixturesfrom1to54mpas