Alterations Induced by Bangerter Filters on the Visual Field: A Frequency Doubling Technology and Standard Automated Perimetry Study
Purpose. To investigate the effects of Bangerter filters on the visual field in healthy and in amblyopic patients. Materials and Methods. Fifteen normal adults and fifteen anisometropic amblyopia patients were analysed with standard automated perimetry (SAP) and frequency doubling technology (FDT) a...
Saved in:
Main Authors: | Costantino Schiavi, Filippo Tassi, Alessandro Finzi, Mauro Cellini |
---|---|
Format: | Article |
Language: | English |
Published: |
Wiley
2015-01-01
|
Series: | Journal of Ophthalmology |
Online Access: | http://dx.doi.org/10.1155/2015/909848 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Similar Items
-
The Effect of Cataract on Eye Movement Perimetry
by: G. Thepass, et al.
Published: (2015-01-01) -
Analysis of Visual Field Defects Obtained with Semiautomated Kinetic Perimetry in Patients with Leber Hereditary Optic Neuropathy
by: Katarzyna Nowomiejska, et al.
Published: (2018-01-01) -
FDT Perimetry for Glaucoma Detection in Comprehensive Health Checkup Service
by: Ryo Terauchi, et al.
Published: (2020-01-01) -
Extraocular Muscles Tension, Tonus, and Proprioception in Infantile Strabismus: Role of the Oculomotor System in the Pathogenesis of Infantile Strabismus—Review of the Literature
by: Costantino Schiavi
Published: (2016-01-01) -
“Perimetri” di sistema. Riflessioni e critiche sul mondo dell’asilo in Italia
by: Maria Concetta Segneri, et al.
Published: (2016-05-01)