Estimation of Eyelid Pressure Using a Blepharo-Tensiometer in Patients with Functional Nasolacrimal Duct Obstruction

Purpose. To compare the eyelid pressure between patients with functional nasolacrimal duct obstruction (FNLDO) and normal controls using blepharo-tensiometer, and to evaluate the relationship between eyelid pressure and the outcomes of silicone intubation (SI) in patients with FNLDO. Study design. P...

Full description

Saved in:
Bibliographic Details
Main Authors: Jinsoo Kim, Sang-Mok Lee, Youn Joo Choi, Min Joung Lee
Format: Article
Language:English
Published: Wiley 2018-01-01
Series:Journal of Ophthalmology
Online Access:http://dx.doi.org/10.1155/2018/8792102
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1832557114176831488
author Jinsoo Kim
Sang-Mok Lee
Youn Joo Choi
Min Joung Lee
author_facet Jinsoo Kim
Sang-Mok Lee
Youn Joo Choi
Min Joung Lee
author_sort Jinsoo Kim
collection DOAJ
description Purpose. To compare the eyelid pressure between patients with functional nasolacrimal duct obstruction (FNLDO) and normal controls using blepharo-tensiometer, and to evaluate the relationship between eyelid pressure and the outcomes of silicone intubation (SI) in patients with FNLDO. Study design. Prospective case-control study. Methods. We enrolled 36 eyes of 36 patients with suspected FNLDO who underwent SI and 36 healthy eyes of age-matched controls. One eye of each patient with FNLDO was randomly selected for analysis. The eyelid pressure was estimated using a blepharo-tensiometer and compared between the control and FNLDO groups. The relationship between eyelid pressure and clinical variables was analyzed. The outcomes of SI were assessed at 6 months after surgery using subjective and objective criteria. Results. The eyelid pressure was significantly lower in the FNLDO group than in the control group P=0.008. In the control group, the eyelid pressure was correlated with age P<0.001 and lower eyelid laxity P=0.016. In the FNLDO group, the eyelid pressure was only correlated with age P<0.001. The success rate of SI for FNLDO was 69.4% (25 of 36 eyes). The eyelid pressure was higher in the surgical success subgroup than in the failure subgroup, although the difference was not statistically significant P=0.08. Conclusions. Our results suggest that the eyelid pressure measured using a blepharo-tensiometer has a diagnostic value since it is decreased in patients with FNLDO. The role of eyelid pressure as a possible predictor of the outcomes of SI for FNLDO should be investigated in further studies. This trial is registered with KCT0002828.
format Article
id doaj-art-8dbf774dc1714d40b56ea1185f97cd8f
institution Kabale University
issn 2090-004X
2090-0058
language English
publishDate 2018-01-01
publisher Wiley
record_format Article
series Journal of Ophthalmology
spelling doaj-art-8dbf774dc1714d40b56ea1185f97cd8f2025-02-03T05:43:35ZengWileyJournal of Ophthalmology2090-004X2090-00582018-01-01201810.1155/2018/87921028792102Estimation of Eyelid Pressure Using a Blepharo-Tensiometer in Patients with Functional Nasolacrimal Duct ObstructionJinsoo Kim0Sang-Mok Lee1Youn Joo Choi2Min Joung Lee3Department of Ophthalmology, Hallym University College of Medicine, Hallym University Sacred Heart Hospital, Anyang, Republic of KoreaDepartment of Cornea, External Disease & Refractive Surgery, HanGil Eye Hospital, Catholic Kwandong University College of Medicine, Incheon, Republic of KoreaDepartment of Ophthalmology, Hallym University College of Medicine, Hallym University Kangdong Sacred Heart Hospital, Seoul, Republic of KoreaDepartment of Ophthalmology, Hallym University College of Medicine, Hallym University Sacred Heart Hospital, Anyang, Republic of KoreaPurpose. To compare the eyelid pressure between patients with functional nasolacrimal duct obstruction (FNLDO) and normal controls using blepharo-tensiometer, and to evaluate the relationship between eyelid pressure and the outcomes of silicone intubation (SI) in patients with FNLDO. Study design. Prospective case-control study. Methods. We enrolled 36 eyes of 36 patients with suspected FNLDO who underwent SI and 36 healthy eyes of age-matched controls. One eye of each patient with FNLDO was randomly selected for analysis. The eyelid pressure was estimated using a blepharo-tensiometer and compared between the control and FNLDO groups. The relationship between eyelid pressure and clinical variables was analyzed. The outcomes of SI were assessed at 6 months after surgery using subjective and objective criteria. Results. The eyelid pressure was significantly lower in the FNLDO group than in the control group P=0.008. In the control group, the eyelid pressure was correlated with age P<0.001 and lower eyelid laxity P=0.016. In the FNLDO group, the eyelid pressure was only correlated with age P<0.001. The success rate of SI for FNLDO was 69.4% (25 of 36 eyes). The eyelid pressure was higher in the surgical success subgroup than in the failure subgroup, although the difference was not statistically significant P=0.08. Conclusions. Our results suggest that the eyelid pressure measured using a blepharo-tensiometer has a diagnostic value since it is decreased in patients with FNLDO. The role of eyelid pressure as a possible predictor of the outcomes of SI for FNLDO should be investigated in further studies. This trial is registered with KCT0002828.http://dx.doi.org/10.1155/2018/8792102
spellingShingle Jinsoo Kim
Sang-Mok Lee
Youn Joo Choi
Min Joung Lee
Estimation of Eyelid Pressure Using a Blepharo-Tensiometer in Patients with Functional Nasolacrimal Duct Obstruction
Journal of Ophthalmology
title Estimation of Eyelid Pressure Using a Blepharo-Tensiometer in Patients with Functional Nasolacrimal Duct Obstruction
title_full Estimation of Eyelid Pressure Using a Blepharo-Tensiometer in Patients with Functional Nasolacrimal Duct Obstruction
title_fullStr Estimation of Eyelid Pressure Using a Blepharo-Tensiometer in Patients with Functional Nasolacrimal Duct Obstruction
title_full_unstemmed Estimation of Eyelid Pressure Using a Blepharo-Tensiometer in Patients with Functional Nasolacrimal Duct Obstruction
title_short Estimation of Eyelid Pressure Using a Blepharo-Tensiometer in Patients with Functional Nasolacrimal Duct Obstruction
title_sort estimation of eyelid pressure using a blepharo tensiometer in patients with functional nasolacrimal duct obstruction
url http://dx.doi.org/10.1155/2018/8792102
work_keys_str_mv AT jinsookim estimationofeyelidpressureusingablepharotensiometerinpatientswithfunctionalnasolacrimalductobstruction
AT sangmoklee estimationofeyelidpressureusingablepharotensiometerinpatientswithfunctionalnasolacrimalductobstruction
AT younjoochoi estimationofeyelidpressureusingablepharotensiometerinpatientswithfunctionalnasolacrimalductobstruction
AT minjounglee estimationofeyelidpressureusingablepharotensiometerinpatientswithfunctionalnasolacrimalductobstruction