Cuff Failure of Spiral-Filled Polyvinyl Chloride Endotracheal Tube Immediately after Tracheal Intubation Using a Channeled Videolaryngoscope (Pentax Airway Scope)

We report on a case of mechanical damage to the spiral-filled polyvinyl chloride endotracheal tube that occurred shortly after tracheal intubation using a channeled videolaryngoscope (Pentax airway scope). We also found this problem in two other cases among 350 neurosurgery patients over the past 5...

Full description

Saved in:
Bibliographic Details
Main Authors: Koichi Nishikawa, Yoshihisa Fujita
Format: Article
Language:English
Published: Wiley 2020-01-01
Series:Case Reports in Anesthesiology
Online Access:http://dx.doi.org/10.1155/2020/3658092
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1832566083260776448
author Koichi Nishikawa
Yoshihisa Fujita
author_facet Koichi Nishikawa
Yoshihisa Fujita
author_sort Koichi Nishikawa
collection DOAJ
description We report on a case of mechanical damage to the spiral-filled polyvinyl chloride endotracheal tube that occurred shortly after tracheal intubation using a channeled videolaryngoscope (Pentax airway scope). We also found this problem in two other cases among 350 neurosurgery patients over the past 5 years. Prior to intubation, we did not observe any defect in the cuff. However, the cuff could not be filled with air immediately after the intubation. Anesthesiologists should be aware that, during tracheal intubation using an airway scope, friction between the endotracheal tube and inner surface of the introducer might result in sudden rupture of the cuff.
format Article
id doaj-art-8dac7a01fcbf4056b2b9e871b58d8eb7
institution Kabale University
issn 2090-6382
2090-6390
language English
publishDate 2020-01-01
publisher Wiley
record_format Article
series Case Reports in Anesthesiology
spelling doaj-art-8dac7a01fcbf4056b2b9e871b58d8eb72025-02-03T01:05:09ZengWileyCase Reports in Anesthesiology2090-63822090-63902020-01-01202010.1155/2020/36580923658092Cuff Failure of Spiral-Filled Polyvinyl Chloride Endotracheal Tube Immediately after Tracheal Intubation Using a Channeled Videolaryngoscope (Pentax Airway Scope)Koichi Nishikawa0Yoshihisa Fujita1Department of Disaster and Comprehensive Medicine, Fukushima Medical University, Fukushima City, JapanDepartment of Medical Engineering, Kawasaki University of Medical Welfare, Kurashiki City, JapanWe report on a case of mechanical damage to the spiral-filled polyvinyl chloride endotracheal tube that occurred shortly after tracheal intubation using a channeled videolaryngoscope (Pentax airway scope). We also found this problem in two other cases among 350 neurosurgery patients over the past 5 years. Prior to intubation, we did not observe any defect in the cuff. However, the cuff could not be filled with air immediately after the intubation. Anesthesiologists should be aware that, during tracheal intubation using an airway scope, friction between the endotracheal tube and inner surface of the introducer might result in sudden rupture of the cuff.http://dx.doi.org/10.1155/2020/3658092
spellingShingle Koichi Nishikawa
Yoshihisa Fujita
Cuff Failure of Spiral-Filled Polyvinyl Chloride Endotracheal Tube Immediately after Tracheal Intubation Using a Channeled Videolaryngoscope (Pentax Airway Scope)
Case Reports in Anesthesiology
title Cuff Failure of Spiral-Filled Polyvinyl Chloride Endotracheal Tube Immediately after Tracheal Intubation Using a Channeled Videolaryngoscope (Pentax Airway Scope)
title_full Cuff Failure of Spiral-Filled Polyvinyl Chloride Endotracheal Tube Immediately after Tracheal Intubation Using a Channeled Videolaryngoscope (Pentax Airway Scope)
title_fullStr Cuff Failure of Spiral-Filled Polyvinyl Chloride Endotracheal Tube Immediately after Tracheal Intubation Using a Channeled Videolaryngoscope (Pentax Airway Scope)
title_full_unstemmed Cuff Failure of Spiral-Filled Polyvinyl Chloride Endotracheal Tube Immediately after Tracheal Intubation Using a Channeled Videolaryngoscope (Pentax Airway Scope)
title_short Cuff Failure of Spiral-Filled Polyvinyl Chloride Endotracheal Tube Immediately after Tracheal Intubation Using a Channeled Videolaryngoscope (Pentax Airway Scope)
title_sort cuff failure of spiral filled polyvinyl chloride endotracheal tube immediately after tracheal intubation using a channeled videolaryngoscope pentax airway scope
url http://dx.doi.org/10.1155/2020/3658092
work_keys_str_mv AT koichinishikawa cufffailureofspiralfilledpolyvinylchlorideendotrachealtubeimmediatelyaftertrachealintubationusingachanneledvideolaryngoscopepentaxairwayscope
AT yoshihisafujita cufffailureofspiralfilledpolyvinylchlorideendotrachealtubeimmediatelyaftertrachealintubationusingachanneledvideolaryngoscopepentaxairwayscope