POWER, METALLURGICAL AND CHEMICAL MECHANICAL ENGINEERING DEVICE OF PIECEWISE-LINEAR APPROXIMATION OF TRANSIENT RESPONSE OF CONTROLLED ELECTRONIC COMPONENTS

Objective. The development of a device for the piecewise-linear approximation of a transient response for controlling an automated system of the production diagnosis of electronic component parameters on functional cells.Methods. A new measuring input circuit was developed for the control of defecti...

Full description

Saved in:
Bibliographic Details
Main Authors: T. A. Ismailov, Kh. M. Gajiyev, D. A. Chelushkin
Format: Article
Language:Russian
Published: Dagestan State Technical University 2017-10-01
Series:Вестник Дагестанского государственного технического университета: Технические науки
Subjects:
Online Access:https://vestnik.dgtu.ru/jour/article/view/395
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1849250171432468480
author T. A. Ismailov
Kh. M. Gajiyev
D. A. Chelushkin
author_facet T. A. Ismailov
Kh. M. Gajiyev
D. A. Chelushkin
author_sort T. A. Ismailov
collection DOAJ
description Objective. The development of a device for the piecewise-linear approximation of a transient response for controlling an automated system of the production diagnosis of electronic component parameters on functional cells.Methods. A new measuring input circuit was developed for the control of defective electronic components on functional cells in order to obtain the integral transient response, provided that circuit parameters can be programmatically altered. In this case, there is no need to exclude the shunting influence of neighbouring elements on functional cells, since all parameters of all electronic equipment connected to the controlled points are taken into account and will influence the formation of the transient process.Results. The input measuring integrated circuit is capable of controlling the transient responses of both individual electronic components and their groups, consisting of various types of active and passive electronic components. The dependency between the systematic error in the piecewise-linear approximation of the transient response of the electronic components on functional cells and the time constant (T) of the input circuit of the measurement unit is established. The minimum value of the systematic error will be obtained with a time constant of the input circuit equal to 0.001 sec.Conclusion. The information form converter in the automated production diagnostic system for monitoring transient response from the diagnosed electronic components after the stimulating voltage drop has been applied will significantly reduce the time for monitoring each functional cell due to a faster conversion process and a simpler process for comparison with reference.
format Article
id doaj-art-8ccff86bdbbe442dba49d8ea0e13fa4e
institution Kabale University
issn 2073-6185
2542-095X
language Russian
publishDate 2017-10-01
publisher Dagestan State Technical University
record_format Article
series Вестник Дагестанского государственного технического университета: Технические науки
spelling doaj-art-8ccff86bdbbe442dba49d8ea0e13fa4e2025-08-20T03:57:21ZrusDagestan State Technical UniversityВестник Дагестанского государственного технического университета: Технические науки2073-61852542-095X2017-10-01442556710.21822/2073-6185-2017-44-2-55-67347POWER, METALLURGICAL AND CHEMICAL MECHANICAL ENGINEERING DEVICE OF PIECEWISE-LINEAR APPROXIMATION OF TRANSIENT RESPONSE OF CONTROLLED ELECTRONIC COMPONENTST. A. Ismailov0Kh. M. Gajiyev1D. A. Chelushkin2Daghestan State Technical UniversityDaghestan State Technical UniversityDaghestan State Technical UniversityObjective. The development of a device for the piecewise-linear approximation of a transient response for controlling an automated system of the production diagnosis of electronic component parameters on functional cells.Methods. A new measuring input circuit was developed for the control of defective electronic components on functional cells in order to obtain the integral transient response, provided that circuit parameters can be programmatically altered. In this case, there is no need to exclude the shunting influence of neighbouring elements on functional cells, since all parameters of all electronic equipment connected to the controlled points are taken into account and will influence the formation of the transient process.Results. The input measuring integrated circuit is capable of controlling the transient responses of both individual electronic components and their groups, consisting of various types of active and passive electronic components. The dependency between the systematic error in the piecewise-linear approximation of the transient response of the electronic components on functional cells and the time constant (T) of the input circuit of the measurement unit is established. The minimum value of the systematic error will be obtained with a time constant of the input circuit equal to 0.001 sec.Conclusion. The information form converter in the automated production diagnostic system for monitoring transient response from the diagnosed electronic components after the stimulating voltage drop has been applied will significantly reduce the time for monitoring each functional cell due to a faster conversion process and a simpler process for comparison with reference.https://vestnik.dgtu.ru/jour/article/view/395information form converterdiagnosticselectronic componentpiecewise-linear approximationtransient responsefunctional cell
spellingShingle T. A. Ismailov
Kh. M. Gajiyev
D. A. Chelushkin
POWER, METALLURGICAL AND CHEMICAL MECHANICAL ENGINEERING DEVICE OF PIECEWISE-LINEAR APPROXIMATION OF TRANSIENT RESPONSE OF CONTROLLED ELECTRONIC COMPONENTS
Вестник Дагестанского государственного технического университета: Технические науки
information form converter
diagnostics
electronic component
piecewise-linear approximation
transient response
functional cell
title POWER, METALLURGICAL AND CHEMICAL MECHANICAL ENGINEERING DEVICE OF PIECEWISE-LINEAR APPROXIMATION OF TRANSIENT RESPONSE OF CONTROLLED ELECTRONIC COMPONENTS
title_full POWER, METALLURGICAL AND CHEMICAL MECHANICAL ENGINEERING DEVICE OF PIECEWISE-LINEAR APPROXIMATION OF TRANSIENT RESPONSE OF CONTROLLED ELECTRONIC COMPONENTS
title_fullStr POWER, METALLURGICAL AND CHEMICAL MECHANICAL ENGINEERING DEVICE OF PIECEWISE-LINEAR APPROXIMATION OF TRANSIENT RESPONSE OF CONTROLLED ELECTRONIC COMPONENTS
title_full_unstemmed POWER, METALLURGICAL AND CHEMICAL MECHANICAL ENGINEERING DEVICE OF PIECEWISE-LINEAR APPROXIMATION OF TRANSIENT RESPONSE OF CONTROLLED ELECTRONIC COMPONENTS
title_short POWER, METALLURGICAL AND CHEMICAL MECHANICAL ENGINEERING DEVICE OF PIECEWISE-LINEAR APPROXIMATION OF TRANSIENT RESPONSE OF CONTROLLED ELECTRONIC COMPONENTS
title_sort power metallurgical and chemical mechanical engineering device of piecewise linear approximation of transient response of controlled electronic components
topic information form converter
diagnostics
electronic component
piecewise-linear approximation
transient response
functional cell
url https://vestnik.dgtu.ru/jour/article/view/395
work_keys_str_mv AT taismailov powermetallurgicalandchemicalmechanicalengineeringdeviceofpiecewiselinearapproximationoftransientresponseofcontrolledelectroniccomponents
AT khmgajiyev powermetallurgicalandchemicalmechanicalengineeringdeviceofpiecewiselinearapproximationoftransientresponseofcontrolledelectroniccomponents
AT dachelushkin powermetallurgicalandchemicalmechanicalengineeringdeviceofpiecewiselinearapproximationoftransientresponseofcontrolledelectroniccomponents