Hearing Thresholds Changes after MRI 1.5T of Head and Neck
Introduction. Exposure to high intensity noise produced by MRI is a cause for concern. This study was conducted to determine the temporary and permanent effects of exposure to noise created by performing MRI on the hearing threshold of the subjects using conventional and extended high frequency audi...
Saved in:
Main Authors: | , , , , , , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Wiley
2019-01-01
|
Series: | Radiology Research and Practice |
Online Access: | http://dx.doi.org/10.1155/2019/8756579 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
_version_ | 1832549593957531648 |
---|---|
author | Maryam Bahaloo Mohammad Hossein Davari Mohammad Sobhan Seyyed Jalil Mirmohammadi Mohammad Taghi Jalalian Mohammad Javad Zare Sakhvidi Farimah Shamsi Sam Mirfendereski Abolfazl Mollasadeghi Amir Houshang Mehrparvar |
author_facet | Maryam Bahaloo Mohammad Hossein Davari Mohammad Sobhan Seyyed Jalil Mirmohammadi Mohammad Taghi Jalalian Mohammad Javad Zare Sakhvidi Farimah Shamsi Sam Mirfendereski Abolfazl Mollasadeghi Amir Houshang Mehrparvar |
author_sort | Maryam Bahaloo |
collection | DOAJ |
description | Introduction. Exposure to high intensity noise produced by MRI is a cause for concern. This study was conducted to determine the temporary and permanent effects of exposure to noise created by performing MRI on the hearing threshold of the subjects using conventional and extended high frequency audiometry. Methods. This semiexperimental study was performed on 35 patients referred to Shahid Rahnemoun Hospital for head and neck MRI due to different clinical conditions. The hearing threshold of patients was measured before, immediately after, and 24 hours after performing 1.5 Tesla MRI using conventional and extended high frequency audiometry. SPSS version 18 was used to compare the mean hearing thresholds before and after MRI using paired T test and repeated measures analysis. Results. Comparison of auditory thresholds in conventional and extended high frequencies before and immediately after MRI showed a significant shift at 4 KHz (P = 0.008 and P = 0.08 for right and left ears), 6 KHz (P = 0.03 and P = 0.01 for right and left ears), and 14 KHz (P =0.03 and P = 0.31 for right and left ears). However, there was no significant difference between audiometric thresholds before and 24 hours after MRI. Conclusion. Noise due to 1.5 Tesla MRI can only cause transient threshold shift. |
format | Article |
id | doaj-art-8ca191028d85498db7f1f25149be4e1d |
institution | Kabale University |
issn | 2090-1941 2090-195X |
language | English |
publishDate | 2019-01-01 |
publisher | Wiley |
record_format | Article |
series | Radiology Research and Practice |
spelling | doaj-art-8ca191028d85498db7f1f25149be4e1d2025-02-03T06:10:59ZengWileyRadiology Research and Practice2090-19412090-195X2019-01-01201910.1155/2019/87565798756579Hearing Thresholds Changes after MRI 1.5T of Head and NeckMaryam Bahaloo0Mohammad Hossein Davari1Mohammad Sobhan2Seyyed Jalil Mirmohammadi3Mohammad Taghi Jalalian4Mohammad Javad Zare Sakhvidi5Farimah Shamsi6Sam Mirfendereski7Abolfazl Mollasadeghi8Amir Houshang Mehrparvar9Industrial Diseases Research Center, Shahid Sadoughi University of Medical Sciences, Yazd 89138-14389, IranIndustrial Diseases Research Center, Shahid Sadoughi University of Medical Sciences, Yazd 89138-14389, IranDepartment of Radiology, Shahid Sadoughi University of Medical Sciences, Yazd 89138-14389, IranIndustrial Diseases Research Center, Shahid Sadoughi University of Medical Sciences, Yazd 89138-14389, IranDepartment of Occupational Medicine, Shahid Sadoughi University of Medical Sciences, Yazd 89138-14389, IranDepartment of Occupational Health, Shahid Sadoughi University of Medical Sciences, Yazd 89138-14389, IranShahid Sadoughi University of Medical Sciences, Yazd 89138-14389, IranDepartment of Radiology, Faculty of Medicine, Shahrekord University of Medical Sciences, Shahrekord 8815713471, IranIndustrial Diseases Research Center, Shahid Sadoughi University of Medical Sciences, Yazd 89138-14389, IranIndustrial Diseases Research Center, Shahid Sadoughi University of Medical Sciences, Yazd 89138-14389, IranIntroduction. Exposure to high intensity noise produced by MRI is a cause for concern. This study was conducted to determine the temporary and permanent effects of exposure to noise created by performing MRI on the hearing threshold of the subjects using conventional and extended high frequency audiometry. Methods. This semiexperimental study was performed on 35 patients referred to Shahid Rahnemoun Hospital for head and neck MRI due to different clinical conditions. The hearing threshold of patients was measured before, immediately after, and 24 hours after performing 1.5 Tesla MRI using conventional and extended high frequency audiometry. SPSS version 18 was used to compare the mean hearing thresholds before and after MRI using paired T test and repeated measures analysis. Results. Comparison of auditory thresholds in conventional and extended high frequencies before and immediately after MRI showed a significant shift at 4 KHz (P = 0.008 and P = 0.08 for right and left ears), 6 KHz (P = 0.03 and P = 0.01 for right and left ears), and 14 KHz (P =0.03 and P = 0.31 for right and left ears). However, there was no significant difference between audiometric thresholds before and 24 hours after MRI. Conclusion. Noise due to 1.5 Tesla MRI can only cause transient threshold shift.http://dx.doi.org/10.1155/2019/8756579 |
spellingShingle | Maryam Bahaloo Mohammad Hossein Davari Mohammad Sobhan Seyyed Jalil Mirmohammadi Mohammad Taghi Jalalian Mohammad Javad Zare Sakhvidi Farimah Shamsi Sam Mirfendereski Abolfazl Mollasadeghi Amir Houshang Mehrparvar Hearing Thresholds Changes after MRI 1.5T of Head and Neck Radiology Research and Practice |
title | Hearing Thresholds Changes after MRI 1.5T of Head and Neck |
title_full | Hearing Thresholds Changes after MRI 1.5T of Head and Neck |
title_fullStr | Hearing Thresholds Changes after MRI 1.5T of Head and Neck |
title_full_unstemmed | Hearing Thresholds Changes after MRI 1.5T of Head and Neck |
title_short | Hearing Thresholds Changes after MRI 1.5T of Head and Neck |
title_sort | hearing thresholds changes after mri 1 5t of head and neck |
url | http://dx.doi.org/10.1155/2019/8756579 |
work_keys_str_mv | AT maryambahaloo hearingthresholdschangesaftermri15tofheadandneck AT mohammadhosseindavari hearingthresholdschangesaftermri15tofheadandneck AT mohammadsobhan hearingthresholdschangesaftermri15tofheadandneck AT seyyedjalilmirmohammadi hearingthresholdschangesaftermri15tofheadandneck AT mohammadtaghijalalian hearingthresholdschangesaftermri15tofheadandneck AT mohammadjavadzaresakhvidi hearingthresholdschangesaftermri15tofheadandneck AT farimahshamsi hearingthresholdschangesaftermri15tofheadandneck AT sammirfendereski hearingthresholdschangesaftermri15tofheadandneck AT abolfazlmollasadeghi hearingthresholdschangesaftermri15tofheadandneck AT amirhoushangmehrparvar hearingthresholdschangesaftermri15tofheadandneck |