Performance Evaluation of Ceiling Cooling with PCM in the Hot-Dry Climate of Yazd, Iran: An Experimental Analysis of Energy, Environmental, and Economic Impacts

The present study investigates experimental cooling from the ceiling using phase change materials (PCMs) in Yazd, a city characterized by a hot and dry climate. A one-fourth scale model of a real room, measuring 4 m × 3 m × 3 m, was employed for the analysis. To evaluate system performance and the i...

Full description

Saved in:
Bibliographic Details
Main Authors: Mehran Rabani, Mina Alafzadeh, Mehrdad Rabani
Format: Article
Language:English
Published: MDPI AG 2025-01-01
Series:Buildings
Subjects:
Online Access:https://www.mdpi.com/2075-5309/15/2/198
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1832588847201910784
author Mehran Rabani
Mina Alafzadeh
Mehrdad Rabani
author_facet Mehran Rabani
Mina Alafzadeh
Mehrdad Rabani
author_sort Mehran Rabani
collection DOAJ
description The present study investigates experimental cooling from the ceiling using phase change materials (PCMs) in Yazd, a city characterized by a hot and dry climate. A one-fourth scale model of a real room, measuring 4 m × 3 m × 3 m, was employed for the analysis. To evaluate system performance and the impact of PCM on energy consumption reduction, three configurations were considered: a simple PCM system, a PCM system with a fan (PCM-F), and a PCM system with a mini cooler (PCM-C). Additionally, to assess the influence of window configurations on ventilation, temperature, and comfort conditions within the model, three scenarios were examined: two open windows, one open window, and no windows. The economic analysis compared the two systems with the fan and mini cooler against a full mechanical cooling system without PCMs. Furthermore, CO<sub>2</sub> emissions and environmental impacts associated with the systems were also evaluated. The results indicate that the presence of PCMs in the ceiling, due to heat absorption during phase change, leads to a temperature reduction of 5 to 10 °C in the ceiling and a 3.2 °C reduction in the average room temperature compared to the scenario without PCMs. The findings demonstrate that ceiling cooling with PCMs significantly contributes to energy consumption reduction during peak hours of cooling demand. Specifically, the PCM-F system results in a 92% reduction, and the PCM-C system leads to a 71% reduction in total cost compared to the reference mechanical cooling system. Additionally, the PCM-F system achieves approximately a 36% reduction, and the PCM-C system results in a 34% reduction in environmental impact relative to the reference full mechanical cooling system.
format Article
id doaj-art-89f555aa7c68480196f2cfad15c4b553
institution Kabale University
issn 2075-5309
language English
publishDate 2025-01-01
publisher MDPI AG
record_format Article
series Buildings
spelling doaj-art-89f555aa7c68480196f2cfad15c4b5532025-01-24T13:26:09ZengMDPI AGBuildings2075-53092025-01-0115219810.3390/buildings15020198Performance Evaluation of Ceiling Cooling with PCM in the Hot-Dry Climate of Yazd, Iran: An Experimental Analysis of Energy, Environmental, and Economic ImpactsMehran Rabani0Mina Alafzadeh1Mehrdad Rabani2Department of Mechanical Engineering, Faculty of Engineering, Ardakan University, Ardakan P.O. Box 184, IranDepartment of Mechanical Engineering, Faculty of Engineering, Ardakan University, Ardakan P.O. Box 184, IranDepartment of Built Environment, Faculty of Technology, Art and Design, Oslo Metropolitan University, P.O. Box 4 Oslo, NorwayThe present study investigates experimental cooling from the ceiling using phase change materials (PCMs) in Yazd, a city characterized by a hot and dry climate. A one-fourth scale model of a real room, measuring 4 m × 3 m × 3 m, was employed for the analysis. To evaluate system performance and the impact of PCM on energy consumption reduction, three configurations were considered: a simple PCM system, a PCM system with a fan (PCM-F), and a PCM system with a mini cooler (PCM-C). Additionally, to assess the influence of window configurations on ventilation, temperature, and comfort conditions within the model, three scenarios were examined: two open windows, one open window, and no windows. The economic analysis compared the two systems with the fan and mini cooler against a full mechanical cooling system without PCMs. Furthermore, CO<sub>2</sub> emissions and environmental impacts associated with the systems were also evaluated. The results indicate that the presence of PCMs in the ceiling, due to heat absorption during phase change, leads to a temperature reduction of 5 to 10 °C in the ceiling and a 3.2 °C reduction in the average room temperature compared to the scenario without PCMs. The findings demonstrate that ceiling cooling with PCMs significantly contributes to energy consumption reduction during peak hours of cooling demand. Specifically, the PCM-F system results in a 92% reduction, and the PCM-C system leads to a 71% reduction in total cost compared to the reference mechanical cooling system. Additionally, the PCM-F system achieves approximately a 36% reduction, and the PCM-C system results in a 34% reduction in environmental impact relative to the reference full mechanical cooling system.https://www.mdpi.com/2075-5309/15/2/198ceiling coolingPCMtotal costenvironmental impactCO<sub>2</sub> emission
spellingShingle Mehran Rabani
Mina Alafzadeh
Mehrdad Rabani
Performance Evaluation of Ceiling Cooling with PCM in the Hot-Dry Climate of Yazd, Iran: An Experimental Analysis of Energy, Environmental, and Economic Impacts
Buildings
ceiling cooling
PCM
total cost
environmental impact
CO<sub>2</sub> emission
title Performance Evaluation of Ceiling Cooling with PCM in the Hot-Dry Climate of Yazd, Iran: An Experimental Analysis of Energy, Environmental, and Economic Impacts
title_full Performance Evaluation of Ceiling Cooling with PCM in the Hot-Dry Climate of Yazd, Iran: An Experimental Analysis of Energy, Environmental, and Economic Impacts
title_fullStr Performance Evaluation of Ceiling Cooling with PCM in the Hot-Dry Climate of Yazd, Iran: An Experimental Analysis of Energy, Environmental, and Economic Impacts
title_full_unstemmed Performance Evaluation of Ceiling Cooling with PCM in the Hot-Dry Climate of Yazd, Iran: An Experimental Analysis of Energy, Environmental, and Economic Impacts
title_short Performance Evaluation of Ceiling Cooling with PCM in the Hot-Dry Climate of Yazd, Iran: An Experimental Analysis of Energy, Environmental, and Economic Impacts
title_sort performance evaluation of ceiling cooling with pcm in the hot dry climate of yazd iran an experimental analysis of energy environmental and economic impacts
topic ceiling cooling
PCM
total cost
environmental impact
CO<sub>2</sub> emission
url https://www.mdpi.com/2075-5309/15/2/198
work_keys_str_mv AT mehranrabani performanceevaluationofceilingcoolingwithpcminthehotdryclimateofyazdirananexperimentalanalysisofenergyenvironmentalandeconomicimpacts
AT minaalafzadeh performanceevaluationofceilingcoolingwithpcminthehotdryclimateofyazdirananexperimentalanalysisofenergyenvironmentalandeconomicimpacts
AT mehrdadrabani performanceevaluationofceilingcoolingwithpcminthehotdryclimateofyazdirananexperimentalanalysisofenergyenvironmentalandeconomicimpacts