Performance Evaluation of Ceiling Cooling with PCM in the Hot-Dry Climate of Yazd, Iran: An Experimental Analysis of Energy, Environmental, and Economic Impacts
The present study investigates experimental cooling from the ceiling using phase change materials (PCMs) in Yazd, a city characterized by a hot and dry climate. A one-fourth scale model of a real room, measuring 4 m × 3 m × 3 m, was employed for the analysis. To evaluate system performance and the i...
Saved in:
Main Authors: | , , |
---|---|
Format: | Article |
Language: | English |
Published: |
MDPI AG
2025-01-01
|
Series: | Buildings |
Subjects: | |
Online Access: | https://www.mdpi.com/2075-5309/15/2/198 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
_version_ | 1832588847201910784 |
---|---|
author | Mehran Rabani Mina Alafzadeh Mehrdad Rabani |
author_facet | Mehran Rabani Mina Alafzadeh Mehrdad Rabani |
author_sort | Mehran Rabani |
collection | DOAJ |
description | The present study investigates experimental cooling from the ceiling using phase change materials (PCMs) in Yazd, a city characterized by a hot and dry climate. A one-fourth scale model of a real room, measuring 4 m × 3 m × 3 m, was employed for the analysis. To evaluate system performance and the impact of PCM on energy consumption reduction, three configurations were considered: a simple PCM system, a PCM system with a fan (PCM-F), and a PCM system with a mini cooler (PCM-C). Additionally, to assess the influence of window configurations on ventilation, temperature, and comfort conditions within the model, three scenarios were examined: two open windows, one open window, and no windows. The economic analysis compared the two systems with the fan and mini cooler against a full mechanical cooling system without PCMs. Furthermore, CO<sub>2</sub> emissions and environmental impacts associated with the systems were also evaluated. The results indicate that the presence of PCMs in the ceiling, due to heat absorption during phase change, leads to a temperature reduction of 5 to 10 °C in the ceiling and a 3.2 °C reduction in the average room temperature compared to the scenario without PCMs. The findings demonstrate that ceiling cooling with PCMs significantly contributes to energy consumption reduction during peak hours of cooling demand. Specifically, the PCM-F system results in a 92% reduction, and the PCM-C system leads to a 71% reduction in total cost compared to the reference mechanical cooling system. Additionally, the PCM-F system achieves approximately a 36% reduction, and the PCM-C system results in a 34% reduction in environmental impact relative to the reference full mechanical cooling system. |
format | Article |
id | doaj-art-89f555aa7c68480196f2cfad15c4b553 |
institution | Kabale University |
issn | 2075-5309 |
language | English |
publishDate | 2025-01-01 |
publisher | MDPI AG |
record_format | Article |
series | Buildings |
spelling | doaj-art-89f555aa7c68480196f2cfad15c4b5532025-01-24T13:26:09ZengMDPI AGBuildings2075-53092025-01-0115219810.3390/buildings15020198Performance Evaluation of Ceiling Cooling with PCM in the Hot-Dry Climate of Yazd, Iran: An Experimental Analysis of Energy, Environmental, and Economic ImpactsMehran Rabani0Mina Alafzadeh1Mehrdad Rabani2Department of Mechanical Engineering, Faculty of Engineering, Ardakan University, Ardakan P.O. Box 184, IranDepartment of Mechanical Engineering, Faculty of Engineering, Ardakan University, Ardakan P.O. Box 184, IranDepartment of Built Environment, Faculty of Technology, Art and Design, Oslo Metropolitan University, P.O. Box 4 Oslo, NorwayThe present study investigates experimental cooling from the ceiling using phase change materials (PCMs) in Yazd, a city characterized by a hot and dry climate. A one-fourth scale model of a real room, measuring 4 m × 3 m × 3 m, was employed for the analysis. To evaluate system performance and the impact of PCM on energy consumption reduction, three configurations were considered: a simple PCM system, a PCM system with a fan (PCM-F), and a PCM system with a mini cooler (PCM-C). Additionally, to assess the influence of window configurations on ventilation, temperature, and comfort conditions within the model, three scenarios were examined: two open windows, one open window, and no windows. The economic analysis compared the two systems with the fan and mini cooler against a full mechanical cooling system without PCMs. Furthermore, CO<sub>2</sub> emissions and environmental impacts associated with the systems were also evaluated. The results indicate that the presence of PCMs in the ceiling, due to heat absorption during phase change, leads to a temperature reduction of 5 to 10 °C in the ceiling and a 3.2 °C reduction in the average room temperature compared to the scenario without PCMs. The findings demonstrate that ceiling cooling with PCMs significantly contributes to energy consumption reduction during peak hours of cooling demand. Specifically, the PCM-F system results in a 92% reduction, and the PCM-C system leads to a 71% reduction in total cost compared to the reference mechanical cooling system. Additionally, the PCM-F system achieves approximately a 36% reduction, and the PCM-C system results in a 34% reduction in environmental impact relative to the reference full mechanical cooling system.https://www.mdpi.com/2075-5309/15/2/198ceiling coolingPCMtotal costenvironmental impactCO<sub>2</sub> emission |
spellingShingle | Mehran Rabani Mina Alafzadeh Mehrdad Rabani Performance Evaluation of Ceiling Cooling with PCM in the Hot-Dry Climate of Yazd, Iran: An Experimental Analysis of Energy, Environmental, and Economic Impacts Buildings ceiling cooling PCM total cost environmental impact CO<sub>2</sub> emission |
title | Performance Evaluation of Ceiling Cooling with PCM in the Hot-Dry Climate of Yazd, Iran: An Experimental Analysis of Energy, Environmental, and Economic Impacts |
title_full | Performance Evaluation of Ceiling Cooling with PCM in the Hot-Dry Climate of Yazd, Iran: An Experimental Analysis of Energy, Environmental, and Economic Impacts |
title_fullStr | Performance Evaluation of Ceiling Cooling with PCM in the Hot-Dry Climate of Yazd, Iran: An Experimental Analysis of Energy, Environmental, and Economic Impacts |
title_full_unstemmed | Performance Evaluation of Ceiling Cooling with PCM in the Hot-Dry Climate of Yazd, Iran: An Experimental Analysis of Energy, Environmental, and Economic Impacts |
title_short | Performance Evaluation of Ceiling Cooling with PCM in the Hot-Dry Climate of Yazd, Iran: An Experimental Analysis of Energy, Environmental, and Economic Impacts |
title_sort | performance evaluation of ceiling cooling with pcm in the hot dry climate of yazd iran an experimental analysis of energy environmental and economic impacts |
topic | ceiling cooling PCM total cost environmental impact CO<sub>2</sub> emission |
url | https://www.mdpi.com/2075-5309/15/2/198 |
work_keys_str_mv | AT mehranrabani performanceevaluationofceilingcoolingwithpcminthehotdryclimateofyazdirananexperimentalanalysisofenergyenvironmentalandeconomicimpacts AT minaalafzadeh performanceevaluationofceilingcoolingwithpcminthehotdryclimateofyazdirananexperimentalanalysisofenergyenvironmentalandeconomicimpacts AT mehrdadrabani performanceevaluationofceilingcoolingwithpcminthehotdryclimateofyazdirananexperimentalanalysisofenergyenvironmentalandeconomicimpacts |