Humidification Performance of Heat and Moisture Exchangers for Pediatric Use

Background. While heat and moisture exchangers (HMEs) have been increasingly used for humidification during mechanical ventilation, the efficacy of pediatric HMEs has not yet been fully evaluated. Methods. We tested ten pediatric HMEs when mechanically ventilating a model lung at respiratory rates o...

Full description

Saved in:
Bibliographic Details
Main Authors: Yusuke Chikata, Chihiro Sumida, Jun Oto, Hideaki Imanaka, Masaji Nishimura
Format: Article
Language:English
Published: Wiley 2012-01-01
Series:Critical Care Research and Practice
Online Access:http://dx.doi.org/10.1155/2012/439267
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1832561028063297536
author Yusuke Chikata
Chihiro Sumida
Jun Oto
Hideaki Imanaka
Masaji Nishimura
author_facet Yusuke Chikata
Chihiro Sumida
Jun Oto
Hideaki Imanaka
Masaji Nishimura
author_sort Yusuke Chikata
collection DOAJ
description Background. While heat and moisture exchangers (HMEs) have been increasingly used for humidification during mechanical ventilation, the efficacy of pediatric HMEs has not yet been fully evaluated. Methods. We tested ten pediatric HMEs when mechanically ventilating a model lung at respiratory rates of 20 and 30 breaths/min and pressure control of 10, 15, and 20 cmH2O. The expiratory gas passed through a heated humidifier. We created two rates of leakage: 3.2 L/min (small) and 5.1 L/min (large) when pressure was 10 cmH2O. We measured absolute humidity (AH) at the Y-piece. Results. Without leakage, eight of ten HMEs maintained AH at more than 30 mg/L. With the small leak, AH decreased below 30 mg/L (26.6 to 29.5 mg/L), decreasing further (19.7 to 27.3 mg/L) with the large leak. Respiratory rate and pressure control level did not affect AH values. Conclusions. Pediatric HMEs provide adequate humidification performance when leakage is absent.
format Article
id doaj-art-8742f5de07264799b6fbea6724c927f1
institution Kabale University
issn 2090-1305
2090-1313
language English
publishDate 2012-01-01
publisher Wiley
record_format Article
series Critical Care Research and Practice
spelling doaj-art-8742f5de07264799b6fbea6724c927f12025-02-03T01:26:13ZengWileyCritical Care Research and Practice2090-13052090-13132012-01-01201210.1155/2012/439267439267Humidification Performance of Heat and Moisture Exchangers for Pediatric UseYusuke Chikata0Chihiro Sumida1Jun Oto2Hideaki Imanaka3Masaji Nishimura4The University of Tokushima Graduate School, 3-18-15 Kuramoto-cho, Tokushima City, Tokushima 770-8503, JapanFaculty of Medicine, The University of Tokushima, 3-18-15 Kuramoto-cho, Tokushima City, Tokushima 770-8503, JapanDepartment of Emergency and Critical Care Medicine, The University of Tokushima Graduate School, 3-18-15 Kuramoto-cho, Tokushima City, Tokushima 770-8503, JapanDepartment of Emergency and Disaster Medicine, Tokushima University Hospital, 2-50-1, Kuramoto-cho, Tokushima City, Tokushima 770-8503, JapanDepartment of Emergency and Critical Care Medicine, The University of Tokushima Graduate School, 3-18-15 Kuramoto-cho, Tokushima City, Tokushima 770-8503, JapanBackground. While heat and moisture exchangers (HMEs) have been increasingly used for humidification during mechanical ventilation, the efficacy of pediatric HMEs has not yet been fully evaluated. Methods. We tested ten pediatric HMEs when mechanically ventilating a model lung at respiratory rates of 20 and 30 breaths/min and pressure control of 10, 15, and 20 cmH2O. The expiratory gas passed through a heated humidifier. We created two rates of leakage: 3.2 L/min (small) and 5.1 L/min (large) when pressure was 10 cmH2O. We measured absolute humidity (AH) at the Y-piece. Results. Without leakage, eight of ten HMEs maintained AH at more than 30 mg/L. With the small leak, AH decreased below 30 mg/L (26.6 to 29.5 mg/L), decreasing further (19.7 to 27.3 mg/L) with the large leak. Respiratory rate and pressure control level did not affect AH values. Conclusions. Pediatric HMEs provide adequate humidification performance when leakage is absent.http://dx.doi.org/10.1155/2012/439267
spellingShingle Yusuke Chikata
Chihiro Sumida
Jun Oto
Hideaki Imanaka
Masaji Nishimura
Humidification Performance of Heat and Moisture Exchangers for Pediatric Use
Critical Care Research and Practice
title Humidification Performance of Heat and Moisture Exchangers for Pediatric Use
title_full Humidification Performance of Heat and Moisture Exchangers for Pediatric Use
title_fullStr Humidification Performance of Heat and Moisture Exchangers for Pediatric Use
title_full_unstemmed Humidification Performance of Heat and Moisture Exchangers for Pediatric Use
title_short Humidification Performance of Heat and Moisture Exchangers for Pediatric Use
title_sort humidification performance of heat and moisture exchangers for pediatric use
url http://dx.doi.org/10.1155/2012/439267
work_keys_str_mv AT yusukechikata humidificationperformanceofheatandmoistureexchangersforpediatricuse
AT chihirosumida humidificationperformanceofheatandmoistureexchangersforpediatricuse
AT junoto humidificationperformanceofheatandmoistureexchangersforpediatricuse
AT hideakiimanaka humidificationperformanceofheatandmoistureexchangersforpediatricuse
AT masajinishimura humidificationperformanceofheatandmoistureexchangersforpediatricuse