A DC Bias Current Reducing Method Considering Grounding Electrode Location and Receiving-end Grid Structure

Based on the influence of the receiving-end grid structure and the grounding electrode location on DC bias current, this paper analyzes the DC bias current (DCBC) level of the converter station and the adjacent AC substation in the typical connection structure under different connection modes of the...

Full description

Saved in:
Bibliographic Details
Main Authors: Lianguang LIU, Chenglian MA
Format: Article
Language:zho
Published: State Grid Energy Research Institute 2021-07-01
Series:Zhongguo dianli
Subjects:
Online Access:https://www.electricpower.com.cn/CN/10.11930/j.issn.1004-9649.201904098
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1850053495602806784
author Lianguang LIU
Chenglian MA
author_facet Lianguang LIU
Chenglian MA
author_sort Lianguang LIU
collection DOAJ
description Based on the influence of the receiving-end grid structure and the grounding electrode location on DC bias current, this paper analyzes the DC bias current (DCBC) level of the converter station and the adjacent AC substation in the typical connection structure under different connection modes of the AC substations. The factors affecting the DCBC value of converter and AC transformers are analyzed, and the influence mechanism of the grounding electrode location and the receiving-end grid structure on the transformer DCBC value is expounded. Considering the structure of receiving-end grid and the location selection of grounding electrode, a DCBC value reduction method for converter and AC transformers is proposed. The measures to suppress the DC bias current can be analyzed from the aspects of system operation mode selection, grounding electrode location selection, power grid structure planning and designing, etc. This paper proposes to prevent the bias current of the converter and AC transformer during the planning and designing stage.
format Article
id doaj-art-85d3df582a2e4fe38a91de1fd16b80ad
institution DOAJ
issn 1004-9649
language zho
publishDate 2021-07-01
publisher State Grid Energy Research Institute
record_format Article
series Zhongguo dianli
spelling doaj-art-85d3df582a2e4fe38a91de1fd16b80ad2025-08-20T02:52:31ZzhoState Grid Energy Research InstituteZhongguo dianli1004-96492021-07-0154710010810.11930/j.issn.1004-9649.201904098zgdl-54-4-liulianguangA DC Bias Current Reducing Method Considering Grounding Electrode Location and Receiving-end Grid StructureLianguang LIU0Chenglian MA1State Key Laboratory of Alternate Electrical Power System with Renewable Energy Sources (North China Electric Power University), Beijing 102206, ChinaState Key Laboratory of Alternate Electrical Power System with Renewable Energy Sources (North China Electric Power University), Beijing 102206, ChinaBased on the influence of the receiving-end grid structure and the grounding electrode location on DC bias current, this paper analyzes the DC bias current (DCBC) level of the converter station and the adjacent AC substation in the typical connection structure under different connection modes of the AC substations. The factors affecting the DCBC value of converter and AC transformers are analyzed, and the influence mechanism of the grounding electrode location and the receiving-end grid structure on the transformer DCBC value is expounded. Considering the structure of receiving-end grid and the location selection of grounding electrode, a DCBC value reduction method for converter and AC transformers is proposed. The measures to suppress the DC bias current can be analyzed from the aspects of system operation mode selection, grounding electrode location selection, power grid structure planning and designing, etc. This paper proposes to prevent the bias current of the converter and AC transformer during the planning and designing stage.https://www.electricpower.com.cn/CN/10.11930/j.issn.1004-9649.201904098uhvdcdc grounding electrodedc bias current (dcbc)receiving-end gridgrid structuregrounding electrode location
spellingShingle Lianguang LIU
Chenglian MA
A DC Bias Current Reducing Method Considering Grounding Electrode Location and Receiving-end Grid Structure
Zhongguo dianli
uhvdc
dc grounding electrode
dc bias current (dcbc)
receiving-end grid
grid structure
grounding electrode location
title A DC Bias Current Reducing Method Considering Grounding Electrode Location and Receiving-end Grid Structure
title_full A DC Bias Current Reducing Method Considering Grounding Electrode Location and Receiving-end Grid Structure
title_fullStr A DC Bias Current Reducing Method Considering Grounding Electrode Location and Receiving-end Grid Structure
title_full_unstemmed A DC Bias Current Reducing Method Considering Grounding Electrode Location and Receiving-end Grid Structure
title_short A DC Bias Current Reducing Method Considering Grounding Electrode Location and Receiving-end Grid Structure
title_sort dc bias current reducing method considering grounding electrode location and receiving end grid structure
topic uhvdc
dc grounding electrode
dc bias current (dcbc)
receiving-end grid
grid structure
grounding electrode location
url https://www.electricpower.com.cn/CN/10.11930/j.issn.1004-9649.201904098
work_keys_str_mv AT lianguangliu adcbiascurrentreducingmethodconsideringgroundingelectrodelocationandreceivingendgridstructure
AT chenglianma adcbiascurrentreducingmethodconsideringgroundingelectrodelocationandreceivingendgridstructure
AT lianguangliu dcbiascurrentreducingmethodconsideringgroundingelectrodelocationandreceivingendgridstructure
AT chenglianma dcbiascurrentreducingmethodconsideringgroundingelectrodelocationandreceivingendgridstructure