Comparison between Accelerometer and Laser Vibrometer to Measure Traffic Excited Vibrations on Bridges

The use of accelerometer based measurement techniques for evaluating bridge forced vibrations or to perform bridge modal analysis is well established. It is well known to all researchers who have experience in vibration measurements that values of acceleration amplitude can be very low at low freque...

Full description

Saved in:
Bibliographic Details
Main Authors: G. Rossi, R. Marsili, V. Gusella, M. Gioffrè
Format: Article
Language:English
Published: Wiley 2002-01-01
Series:Shock and Vibration
Online Access:http://dx.doi.org/10.1155/2002/968509
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1832551056275406848
author G. Rossi
R. Marsili
V. Gusella
M. Gioffrè
author_facet G. Rossi
R. Marsili
V. Gusella
M. Gioffrè
author_sort G. Rossi
collection DOAJ
description The use of accelerometer based measurement techniques for evaluating bridge forced vibrations or to perform bridge modal analysis is well established. It is well known to all researchers who have experience in vibration measurements that values of acceleration amplitude can be very low at low frequencies and that a limitation to the use of accelerometer can be due to the threshold parameter of this kind of transducer. Under this conditions the measurement of displacement seems more appropriate. On the other hand laser vibrometer systems detect relative displacements as opposed to the absolute measures of accelerometers. Vibrations have been measured simultaneously by a typical accelerometer for civil structures and by a laser vibrometer equipped with a fringe counter board in terms of velocity and displacements. The accelerations calculated from the laser vibrometer signals and the one directly measured by the accelerometer has been compared.
format Article
id doaj-art-8235bbd5ad024d958cde99275cc3f91c
institution Kabale University
issn 1070-9622
1875-9203
language English
publishDate 2002-01-01
publisher Wiley
record_format Article
series Shock and Vibration
spelling doaj-art-8235bbd5ad024d958cde99275cc3f91c2025-02-03T06:05:10ZengWileyShock and Vibration1070-96221875-92032002-01-0191-2111810.1155/2002/968509Comparison between Accelerometer and Laser Vibrometer to Measure Traffic Excited Vibrations on BridgesG. Rossi0R. Marsili1V. Gusella2M. Gioffrè3Dip. di Ingegneria Industriale – Universit à degli Studi di Perugia, Via G. Duranti n∘ 1/A-4 – 06125 Perugia, ItalyDip. di Ingegneria Industriale – Universit à degli Studi di Perugia, Via G. Duranti n∘ 1/A-4 – 06125 Perugia, ItalyDip. di Ingegneria Civile e Ambientale – Università degli Studi di Perugia, ItalyDip. di Ingegneria Civile e Ambientale – Università degli Studi di Perugia, ItalyThe use of accelerometer based measurement techniques for evaluating bridge forced vibrations or to perform bridge modal analysis is well established. It is well known to all researchers who have experience in vibration measurements that values of acceleration amplitude can be very low at low frequencies and that a limitation to the use of accelerometer can be due to the threshold parameter of this kind of transducer. Under this conditions the measurement of displacement seems more appropriate. On the other hand laser vibrometer systems detect relative displacements as opposed to the absolute measures of accelerometers. Vibrations have been measured simultaneously by a typical accelerometer for civil structures and by a laser vibrometer equipped with a fringe counter board in terms of velocity and displacements. The accelerations calculated from the laser vibrometer signals and the one directly measured by the accelerometer has been compared.http://dx.doi.org/10.1155/2002/968509
spellingShingle G. Rossi
R. Marsili
V. Gusella
M. Gioffrè
Comparison between Accelerometer and Laser Vibrometer to Measure Traffic Excited Vibrations on Bridges
Shock and Vibration
title Comparison between Accelerometer and Laser Vibrometer to Measure Traffic Excited Vibrations on Bridges
title_full Comparison between Accelerometer and Laser Vibrometer to Measure Traffic Excited Vibrations on Bridges
title_fullStr Comparison between Accelerometer and Laser Vibrometer to Measure Traffic Excited Vibrations on Bridges
title_full_unstemmed Comparison between Accelerometer and Laser Vibrometer to Measure Traffic Excited Vibrations on Bridges
title_short Comparison between Accelerometer and Laser Vibrometer to Measure Traffic Excited Vibrations on Bridges
title_sort comparison between accelerometer and laser vibrometer to measure traffic excited vibrations on bridges
url http://dx.doi.org/10.1155/2002/968509
work_keys_str_mv AT grossi comparisonbetweenaccelerometerandlaservibrometertomeasuretrafficexcitedvibrationsonbridges
AT rmarsili comparisonbetweenaccelerometerandlaservibrometertomeasuretrafficexcitedvibrationsonbridges
AT vgusella comparisonbetweenaccelerometerandlaservibrometertomeasuretrafficexcitedvibrationsonbridges
AT mgioffre comparisonbetweenaccelerometerandlaservibrometertomeasuretrafficexcitedvibrationsonbridges