Numerical Investigation of the Effect of the Number of Blades and the Twist Ratio of the Twisted tape on the Performance of the Double-Pipe Heat Exchanger
In this paper, the effect of a fixed twisted-tape placed in the inner tube of a double-pipe heat exchanger is investigated using numerical simulation. A twisted-tape with three and four blades with different twist ratios is placed in the inner tube of the heat exchanger, and the Nusselt number, fric...
Saved in:
| Main Authors: | Mohammad Reza Tavakoli, Saeed Mohebi |
|---|---|
| Format: | Article |
| Language: | fas |
| Published: |
Semnan University
2024-12-01
|
| Series: | مجله مدل سازی در مهندسی |
| Subjects: | |
| Online Access: | https://modelling.semnan.ac.ir/article_9173_841cb381670eaf998fbf7b7e646e0fc8.pdf |
| Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Similar Items
-
Enhancing heat transfer in compound twisted square ducts using shortened twisted tape inserts
by: Chithra V P, et al.
Published: (2025-06-01) -
The thermal-flow performance of water-Al2O3 nanofluid flow in an elliptical duct heat exchanger equipped with two rotating twisted tapes
by: Hassan Wathiq Ayoob, et al.
Published: (2025-06-01) -
Numerical Evaluation of Using Metal Foam Twisted Tape in Outer Side of a Double-Pipe Heat Exchanger
by: Hassan Hikmat, et al.
Published: (2025-06-01) -
CFD Analysis of Heat Transfer Enhancement for Twisted Tape Inserted in Spirally Corrugated Tubes and Proposal of a New Vane-Inserted Geometry
by: Mouhsine M. Benmbarek, et al.
Published: (2025-03-01) -
Thermal performance enhancement of laminar flow using compound twisted square duct and variable pitch twisted tape inserts
by: V.P. Chithra, et al.
Published: (2024-12-01)