Solidified Floating Organic Drop Microextraction for the Detection of Trace Amount of Lead in Various Samples by Electrothermal Atomic Absorption Spectrometry
A novel method was developed for determination of trace amounts of lead in water and food samples. Solidified floating organic drop microextraction was used to preconcentrate the lead ion. After the analyte was complexed with 1-(2-pyridylazo)-2-naphthol, undecanol and acetonitrile were added as extr...
Saved in:
Main Authors: | , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Wiley
2017-01-01
|
Series: | Journal of Analytical Methods in Chemistry |
Online Access: | http://dx.doi.org/10.1155/2017/6268975 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
_version_ | 1832560479716769792 |
---|---|
author | Oya Aydın Urucu Şeyda Dönmez Ece Kök Yetimoğlu |
author_facet | Oya Aydın Urucu Şeyda Dönmez Ece Kök Yetimoğlu |
author_sort | Oya Aydın Urucu |
collection | DOAJ |
description | A novel method was developed for determination of trace amounts of lead in water and food samples. Solidified floating organic drop microextraction was used to preconcentrate the lead ion. After the analyte was complexed with 1-(2-pyridylazo)-2-naphthol, undecanol and acetonitrile were added as extraction and dispersive solvent, respectively. Variables such as pH, volumes of extraction and dispersive solvents, and concentration of chelating agent were optimized. Under the optimum conditions, the detection limit of Pb (II) was determined as 0.042 µg L−1 with an enrichment factor of 300. The relative standard deviation is <10%. Accuracy of the developed procedure was evaluated by the analysis of certified reference material of human hair (NCS DC 73347) and wastewater (SPS-WW2) with satisfactory results. The developed procedure was then successfully applied to biscuit and water samples for detection of Pb (II) ions. |
format | Article |
id | doaj-art-8142512ce9954b65913e185f0906bb86 |
institution | Kabale University |
issn | 2090-8865 2090-8873 |
language | English |
publishDate | 2017-01-01 |
publisher | Wiley |
record_format | Article |
series | Journal of Analytical Methods in Chemistry |
spelling | doaj-art-8142512ce9954b65913e185f0906bb862025-02-03T01:27:30ZengWileyJournal of Analytical Methods in Chemistry2090-88652090-88732017-01-01201710.1155/2017/62689756268975Solidified Floating Organic Drop Microextraction for the Detection of Trace Amount of Lead in Various Samples by Electrothermal Atomic Absorption SpectrometryOya Aydın Urucu0Şeyda Dönmez1Ece Kök Yetimoğlu2Department of Chemistry, Marmara University, Göztepe, 34722 Istanbul, TurkeyDepartment of Chemistry, Marmara University, Göztepe, 34722 Istanbul, TurkeyDepartment of Chemistry, Marmara University, Göztepe, 34722 Istanbul, TurkeyA novel method was developed for determination of trace amounts of lead in water and food samples. Solidified floating organic drop microextraction was used to preconcentrate the lead ion. After the analyte was complexed with 1-(2-pyridylazo)-2-naphthol, undecanol and acetonitrile were added as extraction and dispersive solvent, respectively. Variables such as pH, volumes of extraction and dispersive solvents, and concentration of chelating agent were optimized. Under the optimum conditions, the detection limit of Pb (II) was determined as 0.042 µg L−1 with an enrichment factor of 300. The relative standard deviation is <10%. Accuracy of the developed procedure was evaluated by the analysis of certified reference material of human hair (NCS DC 73347) and wastewater (SPS-WW2) with satisfactory results. The developed procedure was then successfully applied to biscuit and water samples for detection of Pb (II) ions.http://dx.doi.org/10.1155/2017/6268975 |
spellingShingle | Oya Aydın Urucu Şeyda Dönmez Ece Kök Yetimoğlu Solidified Floating Organic Drop Microextraction for the Detection of Trace Amount of Lead in Various Samples by Electrothermal Atomic Absorption Spectrometry Journal of Analytical Methods in Chemistry |
title | Solidified Floating Organic Drop Microextraction for the Detection of Trace Amount of Lead in Various Samples by Electrothermal Atomic Absorption Spectrometry |
title_full | Solidified Floating Organic Drop Microextraction for the Detection of Trace Amount of Lead in Various Samples by Electrothermal Atomic Absorption Spectrometry |
title_fullStr | Solidified Floating Organic Drop Microextraction for the Detection of Trace Amount of Lead in Various Samples by Electrothermal Atomic Absorption Spectrometry |
title_full_unstemmed | Solidified Floating Organic Drop Microextraction for the Detection of Trace Amount of Lead in Various Samples by Electrothermal Atomic Absorption Spectrometry |
title_short | Solidified Floating Organic Drop Microextraction for the Detection of Trace Amount of Lead in Various Samples by Electrothermal Atomic Absorption Spectrometry |
title_sort | solidified floating organic drop microextraction for the detection of trace amount of lead in various samples by electrothermal atomic absorption spectrometry |
url | http://dx.doi.org/10.1155/2017/6268975 |
work_keys_str_mv | AT oyaaydınurucu solidifiedfloatingorganicdropmicroextractionforthedetectionoftraceamountofleadinvarioussamplesbyelectrothermalatomicabsorptionspectrometry AT seydadonmez solidifiedfloatingorganicdropmicroextractionforthedetectionoftraceamountofleadinvarioussamplesbyelectrothermalatomicabsorptionspectrometry AT ecekokyetimoglu solidifiedfloatingorganicdropmicroextractionforthedetectionoftraceamountofleadinvarioussamplesbyelectrothermalatomicabsorptionspectrometry |