Parametric analysis efficiency screen-vacuum thermal insulation of regenerative heat exchanger heat loss recovery system mobile compressor plant

In this work, a study is conducted of the effectiveness of the screen-vacuum thermal insulation of the heat exchanger of the heat loss recovery system of a mobile compressor unit using the method of its calculation developed on the basis of the Ansys package (Fluid Flow — Fluent). According to the...

Full description

Saved in:
Bibliographic Details
Main Authors: G. I. Chernov, V. L. Yusha, A. M. Kalashnikov
Format: Article
Language:English
Published: Omsk State Technical University, Federal State Autonomous Educational Institution of Higher Education 2019-04-01
Series:Омский научный вестник: Серия "Авиационно-ракетное и энергетическое машиностроение"
Subjects:
Online Access:https://www.omgtu.ru/general_information/media_omgtu/journal_of_omsk_research_journal/files/arhiv/2019/%D0%A2.%203,%20%E2%84%96%201%20(%D0%90%D0%A0%D0%B8%D0%AD%D0%9C)/57-65%20%D0%A7%D0%B5%D1%80%D0%BD%D0%BE%D0%B2%20%D0%93.%20%D0%98.,%20%D0%AE%D1%88%D0%B0%20%D0%92.%20%D0%9B.,%20%D0%9A%D0%B0%D0%BB%D0%B0%D1%88%D0%BD%D0%B8%D0%BA%D0%BE%D0%B2%20%D0%90.%20%D0%9C..pdf
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1832571385865568256
author G. I. Chernov
V. L. Yusha
A. M. Kalashnikov
author_facet G. I. Chernov
V. L. Yusha
A. M. Kalashnikov
author_sort G. I. Chernov
collection DOAJ
description In this work, a study is conducted of the effectiveness of the screen-vacuum thermal insulation of the heat exchanger of the heat loss recovery system of a mobile compressor unit using the method of its calculation developed on the basis of the Ansys package (Fluid Flow — Fluent). According to the results of the numerical analysis of working processes in the flow part of the shell-and-tube recuperative heat exchanger, the interrelation between the parameters of thermal insulation and the characteristics of the heat exchanger has been established
format Article
id doaj-art-801859908d31440bb8d8c851898f3d73
institution Kabale University
issn 2588-0373
2587-764X
language English
publishDate 2019-04-01
publisher Omsk State Technical University, Federal State Autonomous Educational Institution of Higher Education
record_format Article
series Омский научный вестник: Серия "Авиационно-ракетное и энергетическое машиностроение"
spelling doaj-art-801859908d31440bb8d8c851898f3d732025-02-02T12:38:16ZengOmsk State Technical University, Federal State Autonomous Educational Institution of Higher EducationОмский научный вестник: Серия "Авиационно-ракетное и энергетическое машиностроение"2588-03732587-764X2019-04-0131576510.25206/2588-0373-2019-3-1-57-65Parametric analysis efficiency screen-vacuum thermal insulation of regenerative heat exchanger heat loss recovery system mobile compressor plantG. I. Chernov0V. L. Yusha1https://orcid.org/0000-0001-9858-7687A. M. Kalashnikov2https://orcid.org/0000-0002-6847-4937Omsk State Technical UniversityOmsk State Technical UniversityOmsk State Technical UniversityIn this work, a study is conducted of the effectiveness of the screen-vacuum thermal insulation of the heat exchanger of the heat loss recovery system of a mobile compressor unit using the method of its calculation developed on the basis of the Ansys package (Fluid Flow — Fluent). According to the results of the numerical analysis of working processes in the flow part of the shell-and-tube recuperative heat exchanger, the interrelation between the parameters of thermal insulation and the characteristics of the heat exchanger has been establishedhttps://www.omgtu.ru/general_information/media_omgtu/journal_of_omsk_research_journal/files/arhiv/2019/%D0%A2.%203,%20%E2%84%96%201%20(%D0%90%D0%A0%D0%B8%D0%AD%D0%9C)/57-65%20%D0%A7%D0%B5%D1%80%D0%BD%D0%BE%D0%B2%20%D0%93.%20%D0%98.,%20%D0%AE%D1%88%D0%B0%20%D0%92.%20%D0%9B.,%20%D0%9A%D0%B0%D0%BB%D0%B0%D1%88%D0%BD%D0%B8%D0%BA%D0%BE%D0%B2%20%D0%90.%20%D0%9C..pdfheat exchangerrecoverythermal efficiencyheat lossscreen-vacuum insulation
spellingShingle G. I. Chernov
V. L. Yusha
A. M. Kalashnikov
Parametric analysis efficiency screen-vacuum thermal insulation of regenerative heat exchanger heat loss recovery system mobile compressor plant
Омский научный вестник: Серия "Авиационно-ракетное и энергетическое машиностроение"
heat exchanger
recovery
thermal efficiency
heat loss
screen-vacuum insulation
title Parametric analysis efficiency screen-vacuum thermal insulation of regenerative heat exchanger heat loss recovery system mobile compressor plant
title_full Parametric analysis efficiency screen-vacuum thermal insulation of regenerative heat exchanger heat loss recovery system mobile compressor plant
title_fullStr Parametric analysis efficiency screen-vacuum thermal insulation of regenerative heat exchanger heat loss recovery system mobile compressor plant
title_full_unstemmed Parametric analysis efficiency screen-vacuum thermal insulation of regenerative heat exchanger heat loss recovery system mobile compressor plant
title_short Parametric analysis efficiency screen-vacuum thermal insulation of regenerative heat exchanger heat loss recovery system mobile compressor plant
title_sort parametric analysis efficiency screen vacuum thermal insulation of regenerative heat exchanger heat loss recovery system mobile compressor plant
topic heat exchanger
recovery
thermal efficiency
heat loss
screen-vacuum insulation
url https://www.omgtu.ru/general_information/media_omgtu/journal_of_omsk_research_journal/files/arhiv/2019/%D0%A2.%203,%20%E2%84%96%201%20(%D0%90%D0%A0%D0%B8%D0%AD%D0%9C)/57-65%20%D0%A7%D0%B5%D1%80%D0%BD%D0%BE%D0%B2%20%D0%93.%20%D0%98.,%20%D0%AE%D1%88%D0%B0%20%D0%92.%20%D0%9B.,%20%D0%9A%D0%B0%D0%BB%D0%B0%D1%88%D0%BD%D0%B8%D0%BA%D0%BE%D0%B2%20%D0%90.%20%D0%9C..pdf
work_keys_str_mv AT gichernov parametricanalysisefficiencyscreenvacuumthermalinsulationofregenerativeheatexchangerheatlossrecoverysystemmobilecompressorplant
AT vlyusha parametricanalysisefficiencyscreenvacuumthermalinsulationofregenerativeheatexchangerheatlossrecoverysystemmobilecompressorplant
AT amkalashnikov parametricanalysisefficiencyscreenvacuumthermalinsulationofregenerativeheatexchangerheatlossrecoverysystemmobilecompressorplant