Determination of Residual Nonsteroidal Anti-Inflammatory Drugs in Aqueous Sample Using Magnetic Nanoparticles Modified with Cetyltrimethylammonium Bromide by High Performance Liquid Chromatography

A simple and sensitive solid-phase extraction method for separation and preconcentration of trace amount of four nonsteroidal anti-inflammatory drugs (naproxen, indomethacin, diclofenac, and ibuprofen) using Fe3O4 magnetic nanoparticles modified with cetyltrimethylammonium bromide has been developed...

Full description

Saved in:
Bibliographic Details
Main Authors: Malihe Khoeini Sharifabadi, Mohammad Saber-Tehrani, Syed Waqif Husain, Ali Mehdinia, Parviz Aberoomand-Azar
Format: Article
Language:English
Published: Wiley 2014-01-01
Series:The Scientific World Journal
Online Access:http://dx.doi.org/10.1155/2014/127835
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1832559010867314688
author Malihe Khoeini Sharifabadi
Mohammad Saber-Tehrani
Syed Waqif Husain
Ali Mehdinia
Parviz Aberoomand-Azar
author_facet Malihe Khoeini Sharifabadi
Mohammad Saber-Tehrani
Syed Waqif Husain
Ali Mehdinia
Parviz Aberoomand-Azar
author_sort Malihe Khoeini Sharifabadi
collection DOAJ
description A simple and sensitive solid-phase extraction method for separation and preconcentration of trace amount of four nonsteroidal anti-inflammatory drugs (naproxen, indomethacin, diclofenac, and ibuprofen) using Fe3O4 magnetic nanoparticles modified with cetyltrimethylammonium bromide has been developed. For this purpose, the surface of MNPs was modified with cetyltrimethylammonium bromide (CTAB) as a cationic surfactant. Effects of different parameters influencing the extraction efficiency of drugs including the pH, amount of salt, shaking time, eluent type, the volume of solvent, amount of adsorbent, sample volume, and the time of desorption were investigated and optimized. Methanol has been used as desorption solvent and the extracts were analysed on a reversed-phase octadecyl silica column using 0.02 M phosphate-buffer (pH = 6.02) acetonitrile (65 : 35 v/v) as the mobile phase and the effluents were measured at 202 nm with ultraviolet detector. The relative standard deviation (RSD%) of the method was investigated at three concentrations (25, 50, and 200 ng/mL) and was in the range of 3.98–9.83% (n=6) for 50 ng/mL. The calibration curves obtained for studied drugs show reasonable linearity (R2>0.99) and the limit of detection (LODs) ranged between 2 and 7 ng/mL. Finally, the proposed method has been effectively employed in extraction and determination of the drugs in biological and environmental samples.
format Article
id doaj-art-7f9a1ccd6bf44f8a8826160bab35c54b
institution Kabale University
issn 2356-6140
1537-744X
language English
publishDate 2014-01-01
publisher Wiley
record_format Article
series The Scientific World Journal
spelling doaj-art-7f9a1ccd6bf44f8a8826160bab35c54b2025-02-03T01:31:03ZengWileyThe Scientific World Journal2356-61401537-744X2014-01-01201410.1155/2014/127835127835Determination of Residual Nonsteroidal Anti-Inflammatory Drugs in Aqueous Sample Using Magnetic Nanoparticles Modified with Cetyltrimethylammonium Bromide by High Performance Liquid ChromatographyMalihe Khoeini Sharifabadi0Mohammad Saber-Tehrani1Syed Waqif Husain2Ali Mehdinia3Parviz Aberoomand-Azar4Department of Chemistry, Science and Research Branch, Islamic Azad University, Poonak Hesarak, Tehran, IranDepartment of Chemistry, Science and Research Branch, Islamic Azad University, Poonak Hesarak, Tehran, IranDepartment of Chemistry, Science and Research Branch, Islamic Azad University, Poonak Hesarak, Tehran, IranDepartment of Marine Science, Iranian National Institute for Oceanography, Tehran, IranDepartment of Chemistry, Science and Research Branch, Islamic Azad University, Poonak Hesarak, Tehran, IranA simple and sensitive solid-phase extraction method for separation and preconcentration of trace amount of four nonsteroidal anti-inflammatory drugs (naproxen, indomethacin, diclofenac, and ibuprofen) using Fe3O4 magnetic nanoparticles modified with cetyltrimethylammonium bromide has been developed. For this purpose, the surface of MNPs was modified with cetyltrimethylammonium bromide (CTAB) as a cationic surfactant. Effects of different parameters influencing the extraction efficiency of drugs including the pH, amount of salt, shaking time, eluent type, the volume of solvent, amount of adsorbent, sample volume, and the time of desorption were investigated and optimized. Methanol has been used as desorption solvent and the extracts were analysed on a reversed-phase octadecyl silica column using 0.02 M phosphate-buffer (pH = 6.02) acetonitrile (65 : 35 v/v) as the mobile phase and the effluents were measured at 202 nm with ultraviolet detector. The relative standard deviation (RSD%) of the method was investigated at three concentrations (25, 50, and 200 ng/mL) and was in the range of 3.98–9.83% (n=6) for 50 ng/mL. The calibration curves obtained for studied drugs show reasonable linearity (R2>0.99) and the limit of detection (LODs) ranged between 2 and 7 ng/mL. Finally, the proposed method has been effectively employed in extraction and determination of the drugs in biological and environmental samples.http://dx.doi.org/10.1155/2014/127835
spellingShingle Malihe Khoeini Sharifabadi
Mohammad Saber-Tehrani
Syed Waqif Husain
Ali Mehdinia
Parviz Aberoomand-Azar
Determination of Residual Nonsteroidal Anti-Inflammatory Drugs in Aqueous Sample Using Magnetic Nanoparticles Modified with Cetyltrimethylammonium Bromide by High Performance Liquid Chromatography
The Scientific World Journal
title Determination of Residual Nonsteroidal Anti-Inflammatory Drugs in Aqueous Sample Using Magnetic Nanoparticles Modified with Cetyltrimethylammonium Bromide by High Performance Liquid Chromatography
title_full Determination of Residual Nonsteroidal Anti-Inflammatory Drugs in Aqueous Sample Using Magnetic Nanoparticles Modified with Cetyltrimethylammonium Bromide by High Performance Liquid Chromatography
title_fullStr Determination of Residual Nonsteroidal Anti-Inflammatory Drugs in Aqueous Sample Using Magnetic Nanoparticles Modified with Cetyltrimethylammonium Bromide by High Performance Liquid Chromatography
title_full_unstemmed Determination of Residual Nonsteroidal Anti-Inflammatory Drugs in Aqueous Sample Using Magnetic Nanoparticles Modified with Cetyltrimethylammonium Bromide by High Performance Liquid Chromatography
title_short Determination of Residual Nonsteroidal Anti-Inflammatory Drugs in Aqueous Sample Using Magnetic Nanoparticles Modified with Cetyltrimethylammonium Bromide by High Performance Liquid Chromatography
title_sort determination of residual nonsteroidal anti inflammatory drugs in aqueous sample using magnetic nanoparticles modified with cetyltrimethylammonium bromide by high performance liquid chromatography
url http://dx.doi.org/10.1155/2014/127835
work_keys_str_mv AT malihekhoeinisharifabadi determinationofresidualnonsteroidalantiinflammatorydrugsinaqueoussampleusingmagneticnanoparticlesmodifiedwithcetyltrimethylammoniumbromidebyhighperformanceliquidchromatography
AT mohammadsabertehrani determinationofresidualnonsteroidalantiinflammatorydrugsinaqueoussampleusingmagneticnanoparticlesmodifiedwithcetyltrimethylammoniumbromidebyhighperformanceliquidchromatography
AT syedwaqifhusain determinationofresidualnonsteroidalantiinflammatorydrugsinaqueoussampleusingmagneticnanoparticlesmodifiedwithcetyltrimethylammoniumbromidebyhighperformanceliquidchromatography
AT alimehdinia determinationofresidualnonsteroidalantiinflammatorydrugsinaqueoussampleusingmagneticnanoparticlesmodifiedwithcetyltrimethylammoniumbromidebyhighperformanceliquidchromatography
AT parvizaberoomandazar determinationofresidualnonsteroidalantiinflammatorydrugsinaqueoussampleusingmagneticnanoparticlesmodifiedwithcetyltrimethylammoniumbromidebyhighperformanceliquidchromatography