The effect of cable fixation on union time in subtrochanteric femur fractures treated with cephalomedullary nailing
Aim: This study aimed to examine the effect of cable cerclage on reduction quality and union time in patients treated with cephalomedullary nails for subtrochanteric fractures. Materials and Methods: 75 closed subtrochanteric fractures treated with cephalomedullary nails by two different surgeons...
Saved in:
Main Authors: | Fatih İlker Can, Emre Gültaç, Rabia Mihriban Kılınç, Cem Yalın Kılınç |
---|---|
Format: | Article |
Language: | English |
Published: |
Izzet Baysal Training and Research Hospital
2025-01-01
|
Series: | Northwestern Medical Journal |
Subjects: | |
Online Access: | https://nwmedj.org/article/view/140 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Similar Items
-
High Fixation Failure Rate of Cephalomedullary Nail Fixation in Patients with Low-Energy Basicervical Femoral Fractures: Do We Need Extramedullary Reduction?
by: Chang-Jin Yon, et al.
Published: (2025-01-01) -
Atraumatic bilateral subtrochanteric fracture in a young female with osteomalacia
by: Urmila Dhakad, et al.
Published: (2017-01-01) -
Poor radiological outcomes and associated factors among tibial shaft fracture patients treated with intramedullary nail fixation at Addis Ababa Burn, Emergency and Trauma Hospital, Ethiopia
by: Yohannes Shugie, et al.
Published: (2025-02-01) -
A Simple Technique to Locate the Nail Tip in a Buried Interlocking Nail in Femur while Extraction
by: Mugundhan Moongilpatti Sengodan, et al.
Published: (2024-06-01) -
Removal of Misplaced Intramedullary Nails for Proximal Phalanx and Metacarpal Fixation
by: Nirbhay S. Jain, MD, et al.
Published: (2025-01-01)