Evaluation of dominant factors for stability of grid‐connected inverters based on impedance sensitivity analysis

Abstract This article proposes a method for evaluating the dominant factors of grid‐connected inverters based on impedance models, which can achieve quantitative calculation of the dominant factors of system stability. First, an impedance model was established, and an analysis method based on the im...

Full description

Saved in:
Bibliographic Details
Main Authors: Lei Fang, Longji Feng, Chengbo Chu, Jun Xu, Rong Wu, Qingchuan Fan
Format: Article
Language:English
Published: Wiley 2024-12-01
Series:IET Renewable Power Generation
Subjects:
Online Access:https://doi.org/10.1049/rpg2.13020
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1832579860436877312
author Lei Fang
Longji Feng
Chengbo Chu
Jun Xu
Rong Wu
Qingchuan Fan
author_facet Lei Fang
Longji Feng
Chengbo Chu
Jun Xu
Rong Wu
Qingchuan Fan
author_sort Lei Fang
collection DOAJ
description Abstract This article proposes a method for evaluating the dominant factors of grid‐connected inverters based on impedance models, which can achieve quantitative calculation of the dominant factors of system stability. First, an impedance model was established, and an analysis method based on the impedance model was proposed to calculate the absolute sensitivity. The control and circuit parameters of the grid‐connected inverter were calculated, and the impact trend of each parameter on system stability was obtained. Then, in order to eliminate the influence of dimensions between various parameters and achieve traceability of the dominant factors of stability, an absolute sensitivity stability analysis method was proposed to analyze the influencing factors of different frequency bands, and based on this, a suppression scheme of harmonic resonance is proposed. Finally, the accuracy of the method was verified through impedance sweep based on grid‐connected inverters.
format Article
id doaj-art-7e61ebbb2e194756b1140e8680c46f26
institution Kabale University
issn 1752-1416
1752-1424
language English
publishDate 2024-12-01
publisher Wiley
record_format Article
series IET Renewable Power Generation
spelling doaj-art-7e61ebbb2e194756b1140e8680c46f262025-01-30T12:15:53ZengWileyIET Renewable Power Generation1752-14161752-14242024-12-0118163788379710.1049/rpg2.13020Evaluation of dominant factors for stability of grid‐connected inverters based on impedance sensitivity analysisLei Fang0Longji Feng1Chengbo Chu2Jun Xu3Rong Wu4Qingchuan Fan5State Grid Nanjing Power Supply Company Nanjing Jiangsu ChinaState Grid Nanjing Power Supply Company Nanjing Jiangsu ChinaState Grid Nanjing Power Supply Company Nanjing Jiangsu ChinaCollege of Electrical and Information Engineering Hunan University Changsha Hunan ChinaCollege of Electrical and Information Engineering Hunan University Changsha Hunan ChinaCollege of Electrical and Information Engineering Hunan University Changsha Hunan ChinaAbstract This article proposes a method for evaluating the dominant factors of grid‐connected inverters based on impedance models, which can achieve quantitative calculation of the dominant factors of system stability. First, an impedance model was established, and an analysis method based on the impedance model was proposed to calculate the absolute sensitivity. The control and circuit parameters of the grid‐connected inverter were calculated, and the impact trend of each parameter on system stability was obtained. Then, in order to eliminate the influence of dimensions between various parameters and achieve traceability of the dominant factors of stability, an absolute sensitivity stability analysis method was proposed to analyze the influencing factors of different frequency bands, and based on this, a suppression scheme of harmonic resonance is proposed. Finally, the accuracy of the method was verified through impedance sweep based on grid‐connected inverters.https://doi.org/10.1049/rpg2.13020DC‐AC power convertorsimpedance matchingsensitivity analysiswind power
spellingShingle Lei Fang
Longji Feng
Chengbo Chu
Jun Xu
Rong Wu
Qingchuan Fan
Evaluation of dominant factors for stability of grid‐connected inverters based on impedance sensitivity analysis
IET Renewable Power Generation
DC‐AC power convertors
impedance matching
sensitivity analysis
wind power
title Evaluation of dominant factors for stability of grid‐connected inverters based on impedance sensitivity analysis
title_full Evaluation of dominant factors for stability of grid‐connected inverters based on impedance sensitivity analysis
title_fullStr Evaluation of dominant factors for stability of grid‐connected inverters based on impedance sensitivity analysis
title_full_unstemmed Evaluation of dominant factors for stability of grid‐connected inverters based on impedance sensitivity analysis
title_short Evaluation of dominant factors for stability of grid‐connected inverters based on impedance sensitivity analysis
title_sort evaluation of dominant factors for stability of grid connected inverters based on impedance sensitivity analysis
topic DC‐AC power convertors
impedance matching
sensitivity analysis
wind power
url https://doi.org/10.1049/rpg2.13020
work_keys_str_mv AT leifang evaluationofdominantfactorsforstabilityofgridconnectedinvertersbasedonimpedancesensitivityanalysis
AT longjifeng evaluationofdominantfactorsforstabilityofgridconnectedinvertersbasedonimpedancesensitivityanalysis
AT chengbochu evaluationofdominantfactorsforstabilityofgridconnectedinvertersbasedonimpedancesensitivityanalysis
AT junxu evaluationofdominantfactorsforstabilityofgridconnectedinvertersbasedonimpedancesensitivityanalysis
AT rongwu evaluationofdominantfactorsforstabilityofgridconnectedinvertersbasedonimpedancesensitivityanalysis
AT qingchuanfan evaluationofdominantfactorsforstabilityofgridconnectedinvertersbasedonimpedancesensitivityanalysis