Vibration Analysis and Experimental Study of GIS Busbar Enclosure under Electric Force
To explore the vibration response of the GIS busbar enclosure in a strong electric field, the electric force on the busbar enclosure was solved by the voltage in the circuit and the principle of virtual work. The vibration mode was obtained by finite element technology. Accordingly, the vibration re...
Saved in:
Main Authors: | , , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Wiley
2022-01-01
|
Series: | Shock and Vibration |
Online Access: | http://dx.doi.org/10.1155/2022/3055139 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
_version_ | 1832550762670981120 |
---|---|
author | Dingge Yang Yuzhao Li Yanhua Han Bin Ding Liangshu Li Jingfeng Wu |
author_facet | Dingge Yang Yuzhao Li Yanhua Han Bin Ding Liangshu Li Jingfeng Wu |
author_sort | Dingge Yang |
collection | DOAJ |
description | To explore the vibration response of the GIS busbar enclosure in a strong electric field, the electric force on the busbar enclosure was solved by the voltage in the circuit and the principle of virtual work. The vibration mode was obtained by finite element technology. Accordingly, the vibration response of the busbar enclosure was obtained by vibration analysis in the frequency domain, and the vibration acceleration of the busbar was monitored in the substation. The simulation results showed that the busbar enclosure was subjected to the electric force because of the fundamental voltage and harmonic voltages in the conductor. By coupling the radial electric force and the vibration mode, it was found that the vibration responses of the busbar enclosure at 100 Hz and 2900 Hz were greater than those at other frequencies. The experimental result showed that the frequency with the highest vibration amplitude was the same as that of the simulation result, and the vibration acceleration amplitude in the experiment and simulation at 2900 Hz was basically consistent, which verified the accuracy of the simulation result. The study shows that the GIS enclosure shell will produce vibration at the two times power frequency and high frequency, which provides an explanation for the high-frequency vibration of busbar shell structure in the ultra-high-voltage substation and provides an objective basis for the design of the busbar enclosure in the ultra-high-voltage substation. |
format | Article |
id | doaj-art-7d56ab781b594eb3aabe55095976d9f6 |
institution | Kabale University |
issn | 1875-9203 |
language | English |
publishDate | 2022-01-01 |
publisher | Wiley |
record_format | Article |
series | Shock and Vibration |
spelling | doaj-art-7d56ab781b594eb3aabe55095976d9f62025-02-03T06:05:53ZengWileyShock and Vibration1875-92032022-01-01202210.1155/2022/3055139Vibration Analysis and Experimental Study of GIS Busbar Enclosure under Electric ForceDingge Yang0Yuzhao Li1Yanhua Han2Bin Ding3Liangshu Li4Jingfeng Wu5State Grid Shaanxi Electric Power Research InstituteSchool of Mechanical EngineeringState Grid Shaanxi Electric Power Research InstituteState Grid Shaanxi Electric Power Research InstituteState Grid Shaanxi Electric Power Company LimitedState Grid Shaanxi Electric Power Research InstituteTo explore the vibration response of the GIS busbar enclosure in a strong electric field, the electric force on the busbar enclosure was solved by the voltage in the circuit and the principle of virtual work. The vibration mode was obtained by finite element technology. Accordingly, the vibration response of the busbar enclosure was obtained by vibration analysis in the frequency domain, and the vibration acceleration of the busbar was monitored in the substation. The simulation results showed that the busbar enclosure was subjected to the electric force because of the fundamental voltage and harmonic voltages in the conductor. By coupling the radial electric force and the vibration mode, it was found that the vibration responses of the busbar enclosure at 100 Hz and 2900 Hz were greater than those at other frequencies. The experimental result showed that the frequency with the highest vibration amplitude was the same as that of the simulation result, and the vibration acceleration amplitude in the experiment and simulation at 2900 Hz was basically consistent, which verified the accuracy of the simulation result. The study shows that the GIS enclosure shell will produce vibration at the two times power frequency and high frequency, which provides an explanation for the high-frequency vibration of busbar shell structure in the ultra-high-voltage substation and provides an objective basis for the design of the busbar enclosure in the ultra-high-voltage substation.http://dx.doi.org/10.1155/2022/3055139 |
spellingShingle | Dingge Yang Yuzhao Li Yanhua Han Bin Ding Liangshu Li Jingfeng Wu Vibration Analysis and Experimental Study of GIS Busbar Enclosure under Electric Force Shock and Vibration |
title | Vibration Analysis and Experimental Study of GIS Busbar Enclosure under Electric Force |
title_full | Vibration Analysis and Experimental Study of GIS Busbar Enclosure under Electric Force |
title_fullStr | Vibration Analysis and Experimental Study of GIS Busbar Enclosure under Electric Force |
title_full_unstemmed | Vibration Analysis and Experimental Study of GIS Busbar Enclosure under Electric Force |
title_short | Vibration Analysis and Experimental Study of GIS Busbar Enclosure under Electric Force |
title_sort | vibration analysis and experimental study of gis busbar enclosure under electric force |
url | http://dx.doi.org/10.1155/2022/3055139 |
work_keys_str_mv | AT dinggeyang vibrationanalysisandexperimentalstudyofgisbusbarenclosureunderelectricforce AT yuzhaoli vibrationanalysisandexperimentalstudyofgisbusbarenclosureunderelectricforce AT yanhuahan vibrationanalysisandexperimentalstudyofgisbusbarenclosureunderelectricforce AT binding vibrationanalysisandexperimentalstudyofgisbusbarenclosureunderelectricforce AT liangshuli vibrationanalysisandexperimentalstudyofgisbusbarenclosureunderelectricforce AT jingfengwu vibrationanalysisandexperimentalstudyofgisbusbarenclosureunderelectricforce |