Formulation of solution to prevent lysis time erythrocyte and detecting blood type

Background: In the examination of blood type using the tube method, a test cell containing 5% erythrocytes of the solution volume is required. The blood type test using the tube method is carried out in hospital blood banks and in the educational world during practical activities. The obstacle in ma...

Full description

Saved in:
Bibliographic Details
Main Authors: Ria Amelia, Elfira Maya Sari
Format: Article
Language:English
Published: Universitas Muhammadiyah Purwokerto 2025-01-01
Series:Medisains
Subjects:
Online Access:https://jurnalnasional.ump.ac.id/index.php/medisains/article/view/24587
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1832540537830244352
author Ria Amelia
Elfira Maya Sari
author_facet Ria Amelia
Elfira Maya Sari
author_sort Ria Amelia
collection DOAJ
description Background: In the examination of blood type using the tube method, a test cell containing 5% erythrocytes of the solution volume is required. The blood type test using the tube method is carried out in hospital blood banks and in the educational world during practical activities. The obstacle in making a 5% erythrocyte solution is that erythrocytes are lysed so that it is made every day. In addition, making a 5% erythrocyte solution takes a long time so it is not efficient. Purpose: This study aims to find a solution that can maintain erythrocytes for a long time and detecting blood type. Method: This experimental study involved the preparation of 120 tubes containing 5% erythrocyte suspensions from blood types A, B, AB, and O. The samples were diluted in 10 different test solutions, including CPD, ACD, EDTA 5%, Heparin 3%, NaCl 0.9% + glucose (0.025%, 0.05%, 0.1%, 0.2%, and 0.3%), and NaCl 0.9% Daily lysis observations were performed using vortex mixing, centrifugation, and color assessment. The solution with the most extended stability was further tested for ABO blood grouping using the tube method to analyze agglutination patterns. Results: The test solution that can maintain erythrocytes for a long time is the citrate phosphate dextrose (CPD) solution. This solution can prevent erythrocytes for a long time and does not damage erythrocyte antigens. It can also detect blood types well, making blood type examination time more efficient. Conclusion: CPD solution successfully prevents erythrocyte lysis for a longer time compared to other solutions and functions in detecting blood type antibodies.
format Article
id doaj-art-7c3e877c4c6e45d7a4ff933930d6e3ab
institution Kabale University
issn 1693-7309
2621-2366
language English
publishDate 2025-01-01
publisher Universitas Muhammadiyah Purwokerto
record_format Article
series Medisains
spelling doaj-art-7c3e877c4c6e45d7a4ff933930d6e3ab2025-02-04T23:50:18ZengUniversitas Muhammadiyah PurwokertoMedisains1693-73092621-23662025-01-0122315215610.30595/medisains.v22i3.245876582Formulation of solution to prevent lysis time erythrocyte and detecting blood typeRia Amelia0Elfira Maya Sari1STIKes Mitra KeluargaSTIKes Mitra KeluargaBackground: In the examination of blood type using the tube method, a test cell containing 5% erythrocytes of the solution volume is required. The blood type test using the tube method is carried out in hospital blood banks and in the educational world during practical activities. The obstacle in making a 5% erythrocyte solution is that erythrocytes are lysed so that it is made every day. In addition, making a 5% erythrocyte solution takes a long time so it is not efficient. Purpose: This study aims to find a solution that can maintain erythrocytes for a long time and detecting blood type. Method: This experimental study involved the preparation of 120 tubes containing 5% erythrocyte suspensions from blood types A, B, AB, and O. The samples were diluted in 10 different test solutions, including CPD, ACD, EDTA 5%, Heparin 3%, NaCl 0.9% + glucose (0.025%, 0.05%, 0.1%, 0.2%, and 0.3%), and NaCl 0.9% Daily lysis observations were performed using vortex mixing, centrifugation, and color assessment. The solution with the most extended stability was further tested for ABO blood grouping using the tube method to analyze agglutination patterns. Results: The test solution that can maintain erythrocytes for a long time is the citrate phosphate dextrose (CPD) solution. This solution can prevent erythrocytes for a long time and does not damage erythrocyte antigens. It can also detect blood types well, making blood type examination time more efficient. Conclusion: CPD solution successfully prevents erythrocyte lysis for a longer time compared to other solutions and functions in detecting blood type antibodies.https://jurnalnasional.ump.ac.id/index.php/medisains/article/view/24587storage solutionred blood cellserythrocytesblood typesblood lysis
spellingShingle Ria Amelia
Elfira Maya Sari
Formulation of solution to prevent lysis time erythrocyte and detecting blood type
Medisains
storage solution
red blood cells
erythrocytes
blood types
blood lysis
title Formulation of solution to prevent lysis time erythrocyte and detecting blood type
title_full Formulation of solution to prevent lysis time erythrocyte and detecting blood type
title_fullStr Formulation of solution to prevent lysis time erythrocyte and detecting blood type
title_full_unstemmed Formulation of solution to prevent lysis time erythrocyte and detecting blood type
title_short Formulation of solution to prevent lysis time erythrocyte and detecting blood type
title_sort formulation of solution to prevent lysis time erythrocyte and detecting blood type
topic storage solution
red blood cells
erythrocytes
blood types
blood lysis
url https://jurnalnasional.ump.ac.id/index.php/medisains/article/view/24587
work_keys_str_mv AT riaamelia formulationofsolutiontopreventlysistimeerythrocyteanddetectingbloodtype
AT elfiramayasari formulationofsolutiontopreventlysistimeerythrocyteanddetectingbloodtype