Influence of Compressor Station Waste-Heat Recovery Section on Operational Efficiency of Gas Turbine Drive with Isobaric Heat Supply and Regenerative Heat Utilization

The possibility to utilize existing secondary energy resources for heat supply of an industrial enterprise has been proposed on the basis of the analysis on operation of compressor stations of a cross-country gas pipe-line. The paper considers an influence of waste heat recovery section on operation...

Full description

Saved in:
Bibliographic Details
Main Authors: A. P. Nesenchuk, V. N. Romaniuk, A. A. Abrazovsky, A. V. Begliak, T. V. Ryzhova, V. V. Begliak, R. O. Kuzmin
Format: Article
Language:Russian
Published: Belarusian National Technical University 2013-08-01
Series:Известия высших учебных заведений и энергетических объединенний СНГ: Энергетика
Online Access:https://energy.bntu.by/jour/article/view/138
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1832557241306185728
author A. P. Nesenchuk
V. N. Romaniuk
A. A. Abrazovsky
A. V. Begliak
T. V. Ryzhova
V. V. Begliak
R. O. Kuzmin
author_facet A. P. Nesenchuk
V. N. Romaniuk
A. A. Abrazovsky
A. V. Begliak
T. V. Ryzhova
V. V. Begliak
R. O. Kuzmin
author_sort A. P. Nesenchuk
collection DOAJ
description The possibility to utilize existing secondary energy resources for heat supply of an industrial enterprise has been proposed on the basis of the analysis on operation of compressor stations of a cross-country gas pipe-line. The paper considers an influence of waste heat recovery section on operational efficiency of gas turbine drive with regenerative heat utilization.
format Article
id doaj-art-74a087b9f81546438c744c91f45af99d
institution Kabale University
issn 1029-7448
2414-0341
language Russian
publishDate 2013-08-01
publisher Belarusian National Technical University
record_format Article
series Известия высших учебных заведений и энергетических объединенний СНГ: Энергетика
spelling doaj-art-74a087b9f81546438c744c91f45af99d2025-02-03T05:35:43ZrusBelarusian National Technical UniversityИзвестия высших учебных заведений и энергетических объединенний СНГ: Энергетика1029-74482414-03412013-08-0104132Influence of Compressor Station Waste-Heat Recovery Section on Operational Efficiency of Gas Turbine Drive with Isobaric Heat Supply and Regenerative Heat UtilizationA. P. Nesenchuk0V. N. Romaniuk1A. A. Abrazovsky2A. V. Begliak3T. V. Ryzhova4V. V. Begliak5R. O. Kuzmin6Belarusian National Technical UniversityBelarusian National Technical UniversitySIRPD “GAS-INSTITUTE”Belarusian National Technical UniversityMinsk Automobile PlantBelarusian National Technical UniversityBelarusian National Technical UniversityThe possibility to utilize existing secondary energy resources for heat supply of an industrial enterprise has been proposed on the basis of the analysis on operation of compressor stations of a cross-country gas pipe-line. The paper considers an influence of waste heat recovery section on operational efficiency of gas turbine drive with regenerative heat utilization.https://energy.bntu.by/jour/article/view/138
spellingShingle A. P. Nesenchuk
V. N. Romaniuk
A. A. Abrazovsky
A. V. Begliak
T. V. Ryzhova
V. V. Begliak
R. O. Kuzmin
Influence of Compressor Station Waste-Heat Recovery Section on Operational Efficiency of Gas Turbine Drive with Isobaric Heat Supply and Regenerative Heat Utilization
Известия высших учебных заведений и энергетических объединенний СНГ: Энергетика
title Influence of Compressor Station Waste-Heat Recovery Section on Operational Efficiency of Gas Turbine Drive with Isobaric Heat Supply and Regenerative Heat Utilization
title_full Influence of Compressor Station Waste-Heat Recovery Section on Operational Efficiency of Gas Turbine Drive with Isobaric Heat Supply and Regenerative Heat Utilization
title_fullStr Influence of Compressor Station Waste-Heat Recovery Section on Operational Efficiency of Gas Turbine Drive with Isobaric Heat Supply and Regenerative Heat Utilization
title_full_unstemmed Influence of Compressor Station Waste-Heat Recovery Section on Operational Efficiency of Gas Turbine Drive with Isobaric Heat Supply and Regenerative Heat Utilization
title_short Influence of Compressor Station Waste-Heat Recovery Section on Operational Efficiency of Gas Turbine Drive with Isobaric Heat Supply and Regenerative Heat Utilization
title_sort influence of compressor station waste heat recovery section on operational efficiency of gas turbine drive with isobaric heat supply and regenerative heat utilization
url https://energy.bntu.by/jour/article/view/138
work_keys_str_mv AT apnesenchuk influenceofcompressorstationwasteheatrecoverysectiononoperationalefficiencyofgasturbinedrivewithisobaricheatsupplyandregenerativeheatutilization
AT vnromaniuk influenceofcompressorstationwasteheatrecoverysectiononoperationalefficiencyofgasturbinedrivewithisobaricheatsupplyandregenerativeheatutilization
AT aaabrazovsky influenceofcompressorstationwasteheatrecoverysectiononoperationalefficiencyofgasturbinedrivewithisobaricheatsupplyandregenerativeheatutilization
AT avbegliak influenceofcompressorstationwasteheatrecoverysectiononoperationalefficiencyofgasturbinedrivewithisobaricheatsupplyandregenerativeheatutilization
AT tvryzhova influenceofcompressorstationwasteheatrecoverysectiononoperationalefficiencyofgasturbinedrivewithisobaricheatsupplyandregenerativeheatutilization
AT vvbegliak influenceofcompressorstationwasteheatrecoverysectiononoperationalefficiencyofgasturbinedrivewithisobaricheatsupplyandregenerativeheatutilization
AT rokuzmin influenceofcompressorstationwasteheatrecoverysectiononoperationalefficiencyofgasturbinedrivewithisobaricheatsupplyandregenerativeheatutilization