The bearing capacity based on standard penetration test

The stability of building construction or series is not only determined by the upper circuit but the stability of the lower series in this case the foundation plays an equally important role in maintaining the stability of the structure. In planning the foundation, the bearing capacity of the soil i...

Full description

Saved in:
Bibliographic Details
Main Authors: Widiarso Dian Agus, Qadaryati Nurakhmi, Winarno Tri
Format: Article
Language:English
Published: EDP Sciences 2025-01-01
Series:E3S Web of Conferences
Online Access:https://www.e3s-conferences.org/articles/e3sconf/pdf/2025/05/e3sconf_icenis2024_03056.pdf
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1832098518002565120
author Widiarso Dian Agus
Qadaryati Nurakhmi
Winarno Tri
author_facet Widiarso Dian Agus
Qadaryati Nurakhmi
Winarno Tri
author_sort Widiarso Dian Agus
collection DOAJ
description The stability of building construction or series is not only determined by the upper circuit but the stability of the lower series in this case the foundation plays an equally important role in maintaining the stability of the structure. In planning the foundation, the bearing capacity of the soil is an important issue. This research is focused on knowing the bearing capacity value of the allowable bearing capacity formula developed by Meyerhof. This research was conducted in the Tambakharjo area and its surroundings, Semarang City, Central Java. Field data collection includes the results of the standard penetration test (SPT) and undisturbed soil samples (UDS). The N-SPT data was later used to determine the bearing capacity of the soil. The results show a positive linear relationship between N-SPT and carrying capacity, which means the higher the N-SPT, the higher the carrying capacity value. The distribution of bearing capacity at several soil depths is indicated by a zoning map of the bearing capacity of the soil. N-SPT correlation with soil physical properties (clay fraction percentage, plasticity index percentage, and activity value) was also carried out, but most of the data stations were not in accordance with normal conditions.
format Article
id doaj-art-71fb4785925f454e8fc849f5dc290f6d
institution Kabale University
issn 2267-1242
language English
publishDate 2025-01-01
publisher EDP Sciences
record_format Article
series E3S Web of Conferences
spelling doaj-art-71fb4785925f454e8fc849f5dc290f6d2025-02-05T10:49:10ZengEDP SciencesE3S Web of Conferences2267-12422025-01-016050305610.1051/e3sconf/202560503056e3sconf_icenis2024_03056The bearing capacity based on standard penetration testWidiarso Dian Agus0Qadaryati Nurakhmi1Winarno Tri2Geological Engineering Department, Universitas Diponegoro, Jalan Prof. Soedarto, SHGeological Engineering Department, Universitas Diponegoro, Jalan Prof. Soedarto, SHGeological Engineering Department, Universitas Diponegoro, Jalan Prof. Soedarto, SHThe stability of building construction or series is not only determined by the upper circuit but the stability of the lower series in this case the foundation plays an equally important role in maintaining the stability of the structure. In planning the foundation, the bearing capacity of the soil is an important issue. This research is focused on knowing the bearing capacity value of the allowable bearing capacity formula developed by Meyerhof. This research was conducted in the Tambakharjo area and its surroundings, Semarang City, Central Java. Field data collection includes the results of the standard penetration test (SPT) and undisturbed soil samples (UDS). The N-SPT data was later used to determine the bearing capacity of the soil. The results show a positive linear relationship between N-SPT and carrying capacity, which means the higher the N-SPT, the higher the carrying capacity value. The distribution of bearing capacity at several soil depths is indicated by a zoning map of the bearing capacity of the soil. N-SPT correlation with soil physical properties (clay fraction percentage, plasticity index percentage, and activity value) was also carried out, but most of the data stations were not in accordance with normal conditions.https://www.e3s-conferences.org/articles/e3sconf/pdf/2025/05/e3sconf_icenis2024_03056.pdf
spellingShingle Widiarso Dian Agus
Qadaryati Nurakhmi
Winarno Tri
The bearing capacity based on standard penetration test
E3S Web of Conferences
title The bearing capacity based on standard penetration test
title_full The bearing capacity based on standard penetration test
title_fullStr The bearing capacity based on standard penetration test
title_full_unstemmed The bearing capacity based on standard penetration test
title_short The bearing capacity based on standard penetration test
title_sort bearing capacity based on standard penetration test
url https://www.e3s-conferences.org/articles/e3sconf/pdf/2025/05/e3sconf_icenis2024_03056.pdf
work_keys_str_mv AT widiarsodianagus thebearingcapacitybasedonstandardpenetrationtest
AT qadaryatinurakhmi thebearingcapacitybasedonstandardpenetrationtest
AT winarnotri thebearingcapacitybasedonstandardpenetrationtest
AT widiarsodianagus bearingcapacitybasedonstandardpenetrationtest
AT qadaryatinurakhmi bearingcapacitybasedonstandardpenetrationtest
AT winarnotri bearingcapacitybasedonstandardpenetrationtest