Effects of a Newly Developed Therapeutic Deep Heating Device Using High Frequency in Patients with Shoulder Pain and Disability: A Pilot Study
Objectives. The newly developed therapeutic deep heating device can generate deep heat in focal tissue using high-frequency wave stimulation. The objective of this study was to evaluate and compare the effectiveness of this deep heating device (HIPER-500®) with ultrasound in alleviating pain and imp...
Saved in:
Main Authors: | , , , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Wiley
2019-01-01
|
Series: | Pain Research and Management |
Online Access: | http://dx.doi.org/10.1155/2019/8215371 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
_version_ | 1832565032144076800 |
---|---|
author | Gi-Wook Kim Yu Hui Won Sung-Hee Park Jeong-Hwan Seo Dae-hyun Kim Hyung Nam Lee Myoung-Hwan Ko |
author_facet | Gi-Wook Kim Yu Hui Won Sung-Hee Park Jeong-Hwan Seo Dae-hyun Kim Hyung Nam Lee Myoung-Hwan Ko |
author_sort | Gi-Wook Kim |
collection | DOAJ |
description | Objectives. The newly developed therapeutic deep heating device can generate deep heat in focal tissue using high-frequency wave stimulation. The objective of this study was to evaluate and compare the effectiveness of this deep heating device (HIPER-500®) with ultrasound in alleviating pain and improving function in patients with shoulder disability. Methods. This noninferiority trial was designed to compare the treatment effect of HIPER-500® to that of SonoStim® (ultrasound) on shoulder pain and disability. Thirty-eight patients with shoulder problems were assigned to either the HIPER-500® or SonoStim® group, and each participated in 10 min therapy sessions, five days a week for two weeks (for a total of ten sessions). Shoulder pain and disability were evaluated using the Visual Analogue Scale (VAS), the University of California at Los Angeles score (UCLA score), the Shoulder Pain and Disability Index (SPADI), and the Constant score in both groups before, immediately after, and four weeks after treatment. Statistical analysis was performed to compare the effects of treatment within and between the groups. Results. A total of 34 patients completed the study. The 18 patients in the HIPER-500® group and 16 patients in the SonoStim® group all showed significant improvements in shoulder pain and function when comparing pretreatment values with the results immediately after treatment and four weeks later. The results before and after treatment did not show a statistically significant difference between the two groups. Conclusions. The newly developed HIPER-500® for high-frequency deep heat therapy showed similar effects to those of SonoStim® for relieving pain and improving physical performance in the patients of this study. HIPER-500® may be a useful modality for treating shoulder pain and improving physical activity in patients with shoulder disease. |
format | Article |
id | doaj-art-70aafef89d4f452c826f16a512a606bd |
institution | Kabale University |
issn | 1203-6765 1918-1523 |
language | English |
publishDate | 2019-01-01 |
publisher | Wiley |
record_format | Article |
series | Pain Research and Management |
spelling | doaj-art-70aafef89d4f452c826f16a512a606bd2025-02-03T01:09:37ZengWileyPain Research and Management1203-67651918-15232019-01-01201910.1155/2019/82153718215371Effects of a Newly Developed Therapeutic Deep Heating Device Using High Frequency in Patients with Shoulder Pain and Disability: A Pilot StudyGi-Wook Kim0Yu Hui Won1Sung-Hee Park2Jeong-Hwan Seo3Dae-hyun Kim4Hyung Nam Lee5Myoung-Hwan Ko6Department of Physical Medicine & Rehabilitation, Chonbuk National University Medical School, Jeonju 54907, Republic of KoreaDepartment of Physical Medicine & Rehabilitation, Chonbuk National University Medical School, Jeonju 54907, Republic of KoreaDepartment of Physical Medicine & Rehabilitation, Chonbuk National University Medical School, Jeonju 54907, Republic of KoreaDepartment of Physical Medicine & Rehabilitation, Chonbuk National University Medical School, Jeonju 54907, Republic of KoreaDepartment of Physical Medicine & Rehabilitation, Chonbuk National University Medical School, Jeonju 54907, Republic of KoreaDepartment of Physical Medicine & Rehabilitation, Chonbuk National University Medical School, Jeonju 54907, Republic of KoreaDepartment of Physical Medicine & Rehabilitation, Chonbuk National University Medical School, Jeonju 54907, Republic of KoreaObjectives. The newly developed therapeutic deep heating device can generate deep heat in focal tissue using high-frequency wave stimulation. The objective of this study was to evaluate and compare the effectiveness of this deep heating device (HIPER-500®) with ultrasound in alleviating pain and improving function in patients with shoulder disability. Methods. This noninferiority trial was designed to compare the treatment effect of HIPER-500® to that of SonoStim® (ultrasound) on shoulder pain and disability. Thirty-eight patients with shoulder problems were assigned to either the HIPER-500® or SonoStim® group, and each participated in 10 min therapy sessions, five days a week for two weeks (for a total of ten sessions). Shoulder pain and disability were evaluated using the Visual Analogue Scale (VAS), the University of California at Los Angeles score (UCLA score), the Shoulder Pain and Disability Index (SPADI), and the Constant score in both groups before, immediately after, and four weeks after treatment. Statistical analysis was performed to compare the effects of treatment within and between the groups. Results. A total of 34 patients completed the study. The 18 patients in the HIPER-500® group and 16 patients in the SonoStim® group all showed significant improvements in shoulder pain and function when comparing pretreatment values with the results immediately after treatment and four weeks later. The results before and after treatment did not show a statistically significant difference between the two groups. Conclusions. The newly developed HIPER-500® for high-frequency deep heat therapy showed similar effects to those of SonoStim® for relieving pain and improving physical performance in the patients of this study. HIPER-500® may be a useful modality for treating shoulder pain and improving physical activity in patients with shoulder disease.http://dx.doi.org/10.1155/2019/8215371 |
spellingShingle | Gi-Wook Kim Yu Hui Won Sung-Hee Park Jeong-Hwan Seo Dae-hyun Kim Hyung Nam Lee Myoung-Hwan Ko Effects of a Newly Developed Therapeutic Deep Heating Device Using High Frequency in Patients with Shoulder Pain and Disability: A Pilot Study Pain Research and Management |
title | Effects of a Newly Developed Therapeutic Deep Heating Device Using High Frequency in Patients with Shoulder Pain and Disability: A Pilot Study |
title_full | Effects of a Newly Developed Therapeutic Deep Heating Device Using High Frequency in Patients with Shoulder Pain and Disability: A Pilot Study |
title_fullStr | Effects of a Newly Developed Therapeutic Deep Heating Device Using High Frequency in Patients with Shoulder Pain and Disability: A Pilot Study |
title_full_unstemmed | Effects of a Newly Developed Therapeutic Deep Heating Device Using High Frequency in Patients with Shoulder Pain and Disability: A Pilot Study |
title_short | Effects of a Newly Developed Therapeutic Deep Heating Device Using High Frequency in Patients with Shoulder Pain and Disability: A Pilot Study |
title_sort | effects of a newly developed therapeutic deep heating device using high frequency in patients with shoulder pain and disability a pilot study |
url | http://dx.doi.org/10.1155/2019/8215371 |
work_keys_str_mv | AT giwookkim effectsofanewlydevelopedtherapeuticdeepheatingdeviceusinghighfrequencyinpatientswithshoulderpainanddisabilityapilotstudy AT yuhuiwon effectsofanewlydevelopedtherapeuticdeepheatingdeviceusinghighfrequencyinpatientswithshoulderpainanddisabilityapilotstudy AT sungheepark effectsofanewlydevelopedtherapeuticdeepheatingdeviceusinghighfrequencyinpatientswithshoulderpainanddisabilityapilotstudy AT jeonghwanseo effectsofanewlydevelopedtherapeuticdeepheatingdeviceusinghighfrequencyinpatientswithshoulderpainanddisabilityapilotstudy AT daehyunkim effectsofanewlydevelopedtherapeuticdeepheatingdeviceusinghighfrequencyinpatientswithshoulderpainanddisabilityapilotstudy AT hyungnamlee effectsofanewlydevelopedtherapeuticdeepheatingdeviceusinghighfrequencyinpatientswithshoulderpainanddisabilityapilotstudy AT myounghwanko effectsofanewlydevelopedtherapeuticdeepheatingdeviceusinghighfrequencyinpatientswithshoulderpainanddisabilityapilotstudy |