Low Resolution Limits and Inaccurate Algorithms Decrease Significantly the Value of Late Loss in Current Drug-Eluting Stent Trials

Quantitative coronary and vascular angiography (QCA resp., QVA) remains the current gold standard for evaluation of restenosis. Late loss as one of the most commonly accepted parameters to highlight efficacy of the various devices has shown high correlation to clinical parameters but, surprisingly,...

Full description

Saved in:
Bibliographic Details
Main Authors: Johannes B. Dahm, Frank van Buuren
Format: Article
Language:English
Published: Wiley 2012-01-01
Series:International Journal of Vascular Medicine
Online Access:http://dx.doi.org/10.1155/2012/417250
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1832567798844358656
author Johannes B. Dahm
Frank van Buuren
author_facet Johannes B. Dahm
Frank van Buuren
author_sort Johannes B. Dahm
collection DOAJ
description Quantitative coronary and vascular angiography (QCA resp., QVA) remains the current gold standard for evaluation of restenosis. Late loss as one of the most commonly accepted parameters to highlight efficacy of the various devices has shown high correlation to clinical parameters but, surprisingly, has no impact on the evaluation of the remaining amount of restenostic tissue. The current clinical practice leads to unrealistic late loss calculations. Smaller late loss differences are usually not greater than the inherited resolution limits of QCA, which is especially the case in small differences between the various stents in the drug-eluting stent era. Late loss include additional systematic and random errors, due to the fact that measurements were taken at two different time points including the inherited resolution and calibration limits of QCA on two occasions. Due to the limited value of late loss in discriminating the small differences between the one and other DES, late lumen area loss and clearly defined calculation algorithms (e.g., MLD-relocation) should be used in future DES studies also to fulfill the more stringent regulatory requirements.
format Article
id doaj-art-6d11d5c818eb419fb471051953a0bd16
institution Kabale University
issn 2090-2824
2090-2832
language English
publishDate 2012-01-01
publisher Wiley
record_format Article
series International Journal of Vascular Medicine
spelling doaj-art-6d11d5c818eb419fb471051953a0bd162025-02-03T01:00:33ZengWileyInternational Journal of Vascular Medicine2090-28242090-28322012-01-01201210.1155/2012/417250417250Low Resolution Limits and Inaccurate Algorithms Decrease Significantly the Value of Late Loss in Current Drug-Eluting Stent TrialsJohannes B. Dahm0Frank van Buuren1Department of Cardiology-Angiology, Heart and Vascular Center Neu-Bethlehem, Humboldtallee 6, 37073 Göttingen, GermanyDepartment of Cardiology, Heart & Diabetes Center NRW, Georgstrass, 32545 Bad Oeynhausen, GermanyQuantitative coronary and vascular angiography (QCA resp., QVA) remains the current gold standard for evaluation of restenosis. Late loss as one of the most commonly accepted parameters to highlight efficacy of the various devices has shown high correlation to clinical parameters but, surprisingly, has no impact on the evaluation of the remaining amount of restenostic tissue. The current clinical practice leads to unrealistic late loss calculations. Smaller late loss differences are usually not greater than the inherited resolution limits of QCA, which is especially the case in small differences between the various stents in the drug-eluting stent era. Late loss include additional systematic and random errors, due to the fact that measurements were taken at two different time points including the inherited resolution and calibration limits of QCA on two occasions. Due to the limited value of late loss in discriminating the small differences between the one and other DES, late lumen area loss and clearly defined calculation algorithms (e.g., MLD-relocation) should be used in future DES studies also to fulfill the more stringent regulatory requirements.http://dx.doi.org/10.1155/2012/417250
spellingShingle Johannes B. Dahm
Frank van Buuren
Low Resolution Limits and Inaccurate Algorithms Decrease Significantly the Value of Late Loss in Current Drug-Eluting Stent Trials
International Journal of Vascular Medicine
title Low Resolution Limits and Inaccurate Algorithms Decrease Significantly the Value of Late Loss in Current Drug-Eluting Stent Trials
title_full Low Resolution Limits and Inaccurate Algorithms Decrease Significantly the Value of Late Loss in Current Drug-Eluting Stent Trials
title_fullStr Low Resolution Limits and Inaccurate Algorithms Decrease Significantly the Value of Late Loss in Current Drug-Eluting Stent Trials
title_full_unstemmed Low Resolution Limits and Inaccurate Algorithms Decrease Significantly the Value of Late Loss in Current Drug-Eluting Stent Trials
title_short Low Resolution Limits and Inaccurate Algorithms Decrease Significantly the Value of Late Loss in Current Drug-Eluting Stent Trials
title_sort low resolution limits and inaccurate algorithms decrease significantly the value of late loss in current drug eluting stent trials
url http://dx.doi.org/10.1155/2012/417250
work_keys_str_mv AT johannesbdahm lowresolutionlimitsandinaccuratealgorithmsdecreasesignificantlythevalueoflatelossincurrentdrugelutingstenttrials
AT frankvanbuuren lowresolutionlimitsandinaccuratealgorithmsdecreasesignificantlythevalueoflatelossincurrentdrugelutingstenttrials