Application Assessment of OS-SART Reconstruction Algorithm with Limited Number of Projections in XCT Geometric Measurement

 In industrial X-ray Computed Tomography (XCT), two primary kinds of reconstruction algorithms are utilized: the Feldkamp-Davis-Kress (FDK) algorithm and the algebraic reconstruction technique (ART) algorithms. While the FDK algorithm is predominantly employed in industrial XCT due to its competiti...

Full description

Saved in:
Bibliographic Details
Main Authors: Kaojie Yue, Huan Shao, Stefano Petrὸ, Giovanni Moroni
Format: Article
Language:deu
Published: NDT.net 2025-02-01
Series:e-Journal of Nondestructive Testing
Online Access:https://www.ndt.net/search/docs.php3?id=30737
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1832086576996286464
author Kaojie Yue
Huan Shao
Stefano Petrὸ
Giovanni Moroni
author_facet Kaojie Yue
Huan Shao
Stefano Petrὸ
Giovanni Moroni
author_sort Kaojie Yue
collection DOAJ
description  In industrial X-ray Computed Tomography (XCT), two primary kinds of reconstruction algorithms are utilized: the Feldkamp-Davis-Kress (FDK) algorithm and the algebraic reconstruction technique (ART) algorithms. While the FDK algorithm is predominantly employed in industrial XCT due to its competitive efficiency, it necessitates a large number of projections (Np) to yield good 3D images. Conversely, although ART algorithms require relatively longer computational times, their mechanism enables volume reconstruction with a smaller number of projections, thereby offering a potential advantage in scenarios with limited Np. To rigorously investigate the potential of ART algorithms under conditions of limited Np, this study focuses on the ordered subsets simultaneously algebraic reconstruction technique (OS-SART) algorithm, a classic ART algorithm. A series of experiments is conducted, targeting three key algorithmic parameters. These experiments are based on a stepped cylinder part across varying Np levels, with the error between the values of XCT measurement and coordinate measurement machine as the evaluation metric. Eventually, the impacts of these parameters are evaluated based on the experimental results. 
format Article
id doaj-art-6a57a65a714249d4ab3b3054c19fe4cf
institution Kabale University
issn 1435-4934
language deu
publishDate 2025-02-01
publisher NDT.net
record_format Article
series e-Journal of Nondestructive Testing
spelling doaj-art-6a57a65a714249d4ab3b3054c19fe4cf2025-02-06T10:48:19ZdeuNDT.nete-Journal of Nondestructive Testing1435-49342025-02-0130210.58286/30737Application Assessment of OS-SART Reconstruction Algorithm with Limited Number of Projections in XCT Geometric MeasurementKaojie YueHuan ShaoStefano PetrὸGiovanni Moroni  In industrial X-ray Computed Tomography (XCT), two primary kinds of reconstruction algorithms are utilized: the Feldkamp-Davis-Kress (FDK) algorithm and the algebraic reconstruction technique (ART) algorithms. While the FDK algorithm is predominantly employed in industrial XCT due to its competitive efficiency, it necessitates a large number of projections (Np) to yield good 3D images. Conversely, although ART algorithms require relatively longer computational times, their mechanism enables volume reconstruction with a smaller number of projections, thereby offering a potential advantage in scenarios with limited Np. To rigorously investigate the potential of ART algorithms under conditions of limited Np, this study focuses on the ordered subsets simultaneously algebraic reconstruction technique (OS-SART) algorithm, a classic ART algorithm. A series of experiments is conducted, targeting three key algorithmic parameters. These experiments are based on a stepped cylinder part across varying Np levels, with the error between the values of XCT measurement and coordinate measurement machine as the evaluation metric. Eventually, the impacts of these parameters are evaluated based on the experimental results.  https://www.ndt.net/search/docs.php3?id=30737
spellingShingle Kaojie Yue
Huan Shao
Stefano Petrὸ
Giovanni Moroni
Application Assessment of OS-SART Reconstruction Algorithm with Limited Number of Projections in XCT Geometric Measurement
e-Journal of Nondestructive Testing
title Application Assessment of OS-SART Reconstruction Algorithm with Limited Number of Projections in XCT Geometric Measurement
title_full Application Assessment of OS-SART Reconstruction Algorithm with Limited Number of Projections in XCT Geometric Measurement
title_fullStr Application Assessment of OS-SART Reconstruction Algorithm with Limited Number of Projections in XCT Geometric Measurement
title_full_unstemmed Application Assessment of OS-SART Reconstruction Algorithm with Limited Number of Projections in XCT Geometric Measurement
title_short Application Assessment of OS-SART Reconstruction Algorithm with Limited Number of Projections in XCT Geometric Measurement
title_sort application assessment of os sart reconstruction algorithm with limited number of projections in xct geometric measurement
url https://www.ndt.net/search/docs.php3?id=30737
work_keys_str_mv AT kaojieyue applicationassessmentofossartreconstructionalgorithmwithlimitednumberofprojectionsinxctgeometricmeasurement
AT huanshao applicationassessmentofossartreconstructionalgorithmwithlimitednumberofprojectionsinxctgeometricmeasurement
AT stefanopetro applicationassessmentofossartreconstructionalgorithmwithlimitednumberofprojectionsinxctgeometricmeasurement
AT giovannimoroni applicationassessmentofossartreconstructionalgorithmwithlimitednumberofprojectionsinxctgeometricmeasurement