In vitro Evaluation of Repair Bond Strength to Bulk-fill Composites Using Two Silane-Free Universal Adhesives, with and without Silane Application

Objective: To evaluate the effect of silane-free universal adhesives systems on the repair shear bond strength (SBS) of sonic-activated bulk-fill [SonicFill (SF) Kerr, USA] composite applying additional silane in the repair of bulk-fill composite. Methods: Sonic-activated bulk-fill composite sample...

Full description

Saved in:
Bibliographic Details
Main Authors: Alara AKSOY, Nazmiye DÖNMEZ
Format: Article
Language:English
Published: Galenos Publishing House 2025-01-01
Series:Bezmiâlem Science
Subjects:
Online Access:https://www.bezmialemscience.org/articles/lessemgreaterin-vitro-lessemgreaterevaluation-of-repair-bond-strength-to-bulk-fill-composites-using-two-silane-free-universal-adhesives-with-and-without-silane-application/doi/bas.galenos.2024.31644
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1832584595193724928
author Alara AKSOY
Nazmiye DÖNMEZ
author_facet Alara AKSOY
Nazmiye DÖNMEZ
author_sort Alara AKSOY
collection DOAJ
description Objective: To evaluate the effect of silane-free universal adhesives systems on the repair shear bond strength (SBS) of sonic-activated bulk-fill [SonicFill (SF) Kerr, USA] composite applying additional silane in the repair of bulk-fill composite. Methods: Sonic-activated bulk-fill composite samples (n=40) were prepared using a teflon mold (6 mm x 4 mm) and polymerized. Then all samples were kept in an incubator to simulate the aging process at 37 °C for one month. Aged composite samples were embedded in acrylic resin. For the repair, the specimen surfaces were roughened with a diamond bur. They were divided into 2 groups (n=20) according to the adhesive system used and then into two subgroups (n=10) as additional silane was applied or unapplied. Adhesive systems Ambar Universal Bond (AUB), (FGM, Brazil), G-Premio Bond (GPB) (GC, USA) and silane (G-Multi primer GC, Tokyo, Japan) were applied according to the manufacturer’s instructions. Samples were subjected to a shear bond test in a universal testing device. For statistical analysis, one-way ANOVA test was performed (p<0.05). Results: The highest SBS value was obtained in the silane-treated AUB group (21.88±6.4), while the lowest SBS value was obtained in the silane-treated GPB group (16.07±6.2). No statistically significant difference was observed between all groups (p<0.05). Conclusion: Additional silane application does not affect the SBS of universal adhesives on an SF composite material.
format Article
id doaj-art-6a2b532c86d24627856cfc8d9b5746a1
institution Kabale University
issn 2148-2373
language English
publishDate 2025-01-01
publisher Galenos Publishing House
record_format Article
series Bezmiâlem Science
spelling doaj-art-6a2b532c86d24627856cfc8d9b5746a12025-01-27T12:32:52ZengGalenos Publishing HouseBezmiâlem Science2148-23732025-01-01131455010.14235/bas.galenos.2024.31644In vitro Evaluation of Repair Bond Strength to Bulk-fill Composites Using Two Silane-Free Universal Adhesives, with and without Silane ApplicationAlara AKSOY0https://orcid.org/0000-0001-9260-1986Nazmiye DÖNMEZ1https://orcid.org/0000-0002-5101-6155Bezmialem Vakıf University, Institute of Health Sciences, Department of Restorative Dentistry, Istanbul, TürkiyeBolu Abant İzzet Baysal University Faculty of Dentistry, Department of Restorative Dentistry, Bolu, TürkiyeObjective: To evaluate the effect of silane-free universal adhesives systems on the repair shear bond strength (SBS) of sonic-activated bulk-fill [SonicFill (SF) Kerr, USA] composite applying additional silane in the repair of bulk-fill composite. Methods: Sonic-activated bulk-fill composite samples (n=40) were prepared using a teflon mold (6 mm x 4 mm) and polymerized. Then all samples were kept in an incubator to simulate the aging process at 37 °C for one month. Aged composite samples were embedded in acrylic resin. For the repair, the specimen surfaces were roughened with a diamond bur. They were divided into 2 groups (n=20) according to the adhesive system used and then into two subgroups (n=10) as additional silane was applied or unapplied. Adhesive systems Ambar Universal Bond (AUB), (FGM, Brazil), G-Premio Bond (GPB) (GC, USA) and silane (G-Multi primer GC, Tokyo, Japan) were applied according to the manufacturer’s instructions. Samples were subjected to a shear bond test in a universal testing device. For statistical analysis, one-way ANOVA test was performed (p<0.05). Results: The highest SBS value was obtained in the silane-treated AUB group (21.88±6.4), while the lowest SBS value was obtained in the silane-treated GPB group (16.07±6.2). No statistically significant difference was observed between all groups (p<0.05). Conclusion: Additional silane application does not affect the SBS of universal adhesives on an SF composite material.https://www.bezmialemscience.org/articles/lessemgreaterin-vitro-lessemgreaterevaluation-of-repair-bond-strength-to-bulk-fill-composites-using-two-silane-free-universal-adhesives-with-and-without-silane-application/doi/bas.galenos.2024.31644bulk-fill composite repairsonic-activated bulk-fill compositesurface treatmentssilane agentuniversal adhesive
spellingShingle Alara AKSOY
Nazmiye DÖNMEZ
In vitro Evaluation of Repair Bond Strength to Bulk-fill Composites Using Two Silane-Free Universal Adhesives, with and without Silane Application
Bezmiâlem Science
bulk-fill composite repair
sonic-activated bulk-fill composite
surface treatments
silane agent
universal adhesive
title In vitro Evaluation of Repair Bond Strength to Bulk-fill Composites Using Two Silane-Free Universal Adhesives, with and without Silane Application
title_full In vitro Evaluation of Repair Bond Strength to Bulk-fill Composites Using Two Silane-Free Universal Adhesives, with and without Silane Application
title_fullStr In vitro Evaluation of Repair Bond Strength to Bulk-fill Composites Using Two Silane-Free Universal Adhesives, with and without Silane Application
title_full_unstemmed In vitro Evaluation of Repair Bond Strength to Bulk-fill Composites Using Two Silane-Free Universal Adhesives, with and without Silane Application
title_short In vitro Evaluation of Repair Bond Strength to Bulk-fill Composites Using Two Silane-Free Universal Adhesives, with and without Silane Application
title_sort in vitro evaluation of repair bond strength to bulk fill composites using two silane free universal adhesives with and without silane application
topic bulk-fill composite repair
sonic-activated bulk-fill composite
surface treatments
silane agent
universal adhesive
url https://www.bezmialemscience.org/articles/lessemgreaterin-vitro-lessemgreaterevaluation-of-repair-bond-strength-to-bulk-fill-composites-using-two-silane-free-universal-adhesives-with-and-without-silane-application/doi/bas.galenos.2024.31644
work_keys_str_mv AT alaraaksoy invitroevaluationofrepairbondstrengthtobulkfillcompositesusingtwosilanefreeuniversaladhesiveswithandwithoutsilaneapplication
AT nazmiyedonmez invitroevaluationofrepairbondstrengthtobulkfillcompositesusingtwosilanefreeuniversaladhesiveswithandwithoutsilaneapplication