Test method for static parameter of unipolar ADC

The static parameters of analog to digital converter (ADC) include differential nonlinearity (DNL) and integral nonlinearity (INL). The main method to measure static parameters is the code density histogram method.The traditional code density histogram method has high requirements on the calculation...

Full description

Saved in:
Bibliographic Details
Main Authors: Zhu Qing, Wei Kai, Tao Qingping
Format: Article
Language:zho
Published: National Computer System Engineering Research Institute of China 2024-02-01
Series:Dianzi Jishu Yingyong
Subjects:
Online Access:http://www.chinaaet.com/article/3000163470
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:The static parameters of analog to digital converter (ADC) include differential nonlinearity (DNL) and integral nonlinearity (INL). The main method to measure static parameters is the code density histogram method.The traditional code density histogram method has high requirements on the calculation accuracy of input sinusoidal amplitude. This paper proposes a normalized processing platform scheme based on code density histogram. According to the test requirements, the test excitation amplitude that meets the requirements is selected to verify the effectiveness of the normalized scheme.The experimental results show that normalization reduces the influence of sinusoidal amplitude change on the code density histogram method and improves the stability of the code density histogram method.
ISSN:0258-7998