Severe Accident Simulation of the Laguna Verde Nuclear Power Plant
The loss-of-coolant accident (LOCA) simulation in the boiling water reactor (BWR) of Laguna Verde Nuclear Power Plant (LVNPP) at 105% of rated power is analyzed in this work. The LVNPP model was developed using RELAP/SCDAPSIM code. The lack of cooling water after the LOCA gets to the LVNPP to meltin...
Saved in:
Main Authors: | Gilberto Espinosa-Paredes, Raúl Camargo-Camargo, Alejandro Nuñez-Carrera |
---|---|
Format: | Article |
Language: | English |
Published: |
Wiley
2012-01-01
|
Series: | Science and Technology of Nuclear Installations |
Online Access: | http://dx.doi.org/10.1155/2012/209420 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Similar Items
-
Simulation of the Lower Head Boiling Water Reactor Vessel in a Severe Accident
by: Alejandro Nuñez-Carrera, et al.
Published: (2012-01-01) -
Antineutrino Flux from the Laguna Verde Nuclear Power Plant
by: Marisol Chavez-Estrada, et al.
Published: (2015-01-01) -
A Case Study of Nearshore Wave Transformation Processes along the Coast of Mexico near the Laguna Verde Nuclear Power Plant Using a Fast Simulation Method
by: Israel-Enrique Herrera-Díaz, et al.
Published: (2010-01-01) -
Radiation Dose Calculations for a Hypothetical Accident in Xianning Nuclear Power Plant
by: Bo Cao, et al.
Published: (2016-01-01) -
Study on Airborne Radionuclide Dispersion in Floating Nuclear Power Plant under the Loss-of-Coolant Accident
by: Shuliang Zou, et al.