Protein Detection with Potentiometric Aptasensors: A Comparative Study between Polyaniline and Single-Walled Carbon Nanotubes Transducers

A comparison study on the performance characteristics and surface characterization of two different solid-contact selective potentiometric thrombin aptasensors, one exploiting a network of single-walled carbon nanotubes (SWCNTs) and the other the polyaniline (PANI), both acting as a transducing elem...

Full description

Saved in:
Bibliographic Details
Main Authors: Ali Düzgün, Hassan Imran, Kalle Levon, F. Xavier Rius
Format: Article
Language:English
Published: Wiley 2013-01-01
Series:The Scientific World Journal
Online Access:http://dx.doi.org/10.1155/2013/282756
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1832568433980473344
author Ali Düzgün
Hassan Imran
Kalle Levon
F. Xavier Rius
author_facet Ali Düzgün
Hassan Imran
Kalle Levon
F. Xavier Rius
author_sort Ali Düzgün
collection DOAJ
description A comparison study on the performance characteristics and surface characterization of two different solid-contact selective potentiometric thrombin aptasensors, one exploiting a network of single-walled carbon nanotubes (SWCNTs) and the other the polyaniline (PANI), both acting as a transducing element, is described in this work. The molecular properties of both SWCNT and PANI surfaces have been modified by covalently linking thrombin binding aptamers as biorecognition elements. The two aptasensors are compared and characterized through potentiometry and electrochemical impedance spectroscopy (EIS) based on the voltammetric response of multiply charged transition metal cations (such as hexaammineruthenium, [Ru(NH3)6]3+) bound electrostatically to the DNA probes. The surface densities of aptamers were accurately determined by the integration of the peak for the reduction of [Ru(NH3)6]3+ to [Ru(NH3)6]2+. The differences and the similarities, as well as the transduction mechanism, are also discussed. The sensitivity is calculated as 2.97 mV/decade and 8.03 mV/decade for the PANI and SWCNTs aptasensors, respectively. These results are in accordance with the higher surface density of the aptamers in the SWCNT potentiometric sensor.
format Article
id doaj-art-67a00ebf4f4040d996ededdf4310557d
institution Kabale University
issn 1537-744X
language English
publishDate 2013-01-01
publisher Wiley
record_format Article
series The Scientific World Journal
spelling doaj-art-67a00ebf4f4040d996ededdf4310557d2025-02-03T00:59:05ZengWileyThe Scientific World Journal1537-744X2013-01-01201310.1155/2013/282756282756Protein Detection with Potentiometric Aptasensors: A Comparative Study between Polyaniline and Single-Walled Carbon Nanotubes TransducersAli Düzgün0Hassan Imran1Kalle Levon2F. Xavier Rius3Department of Analytical and Organic Chemistry, Universitat Rovira i Virgili, Campus Sescelades, Marcel·lí Domingo, 43007 Tarragona, SpainDepartment of Chemical and Biological Sciences, Polytechnic Institute of New York University, Brooklyn, NY 11201, USADepartment of Chemical and Biological Sciences, Polytechnic Institute of New York University, Brooklyn, NY 11201, USADepartment of Analytical and Organic Chemistry, Universitat Rovira i Virgili, Campus Sescelades, Marcel·lí Domingo, 43007 Tarragona, SpainA comparison study on the performance characteristics and surface characterization of two different solid-contact selective potentiometric thrombin aptasensors, one exploiting a network of single-walled carbon nanotubes (SWCNTs) and the other the polyaniline (PANI), both acting as a transducing element, is described in this work. The molecular properties of both SWCNT and PANI surfaces have been modified by covalently linking thrombin binding aptamers as biorecognition elements. The two aptasensors are compared and characterized through potentiometry and electrochemical impedance spectroscopy (EIS) based on the voltammetric response of multiply charged transition metal cations (such as hexaammineruthenium, [Ru(NH3)6]3+) bound electrostatically to the DNA probes. The surface densities of aptamers were accurately determined by the integration of the peak for the reduction of [Ru(NH3)6]3+ to [Ru(NH3)6]2+. The differences and the similarities, as well as the transduction mechanism, are also discussed. The sensitivity is calculated as 2.97 mV/decade and 8.03 mV/decade for the PANI and SWCNTs aptasensors, respectively. These results are in accordance with the higher surface density of the aptamers in the SWCNT potentiometric sensor.http://dx.doi.org/10.1155/2013/282756
spellingShingle Ali Düzgün
Hassan Imran
Kalle Levon
F. Xavier Rius
Protein Detection with Potentiometric Aptasensors: A Comparative Study between Polyaniline and Single-Walled Carbon Nanotubes Transducers
The Scientific World Journal
title Protein Detection with Potentiometric Aptasensors: A Comparative Study between Polyaniline and Single-Walled Carbon Nanotubes Transducers
title_full Protein Detection with Potentiometric Aptasensors: A Comparative Study between Polyaniline and Single-Walled Carbon Nanotubes Transducers
title_fullStr Protein Detection with Potentiometric Aptasensors: A Comparative Study between Polyaniline and Single-Walled Carbon Nanotubes Transducers
title_full_unstemmed Protein Detection with Potentiometric Aptasensors: A Comparative Study between Polyaniline and Single-Walled Carbon Nanotubes Transducers
title_short Protein Detection with Potentiometric Aptasensors: A Comparative Study between Polyaniline and Single-Walled Carbon Nanotubes Transducers
title_sort protein detection with potentiometric aptasensors a comparative study between polyaniline and single walled carbon nanotubes transducers
url http://dx.doi.org/10.1155/2013/282756
work_keys_str_mv AT aliduzgun proteindetectionwithpotentiometricaptasensorsacomparativestudybetweenpolyanilineandsinglewalledcarbonnanotubestransducers
AT hassanimran proteindetectionwithpotentiometricaptasensorsacomparativestudybetweenpolyanilineandsinglewalledcarbonnanotubestransducers
AT kallelevon proteindetectionwithpotentiometricaptasensorsacomparativestudybetweenpolyanilineandsinglewalledcarbonnanotubestransducers
AT fxavierrius proteindetectionwithpotentiometricaptasensorsacomparativestudybetweenpolyanilineandsinglewalledcarbonnanotubestransducers