The reliability, sensitivity and specificity of fluorescent oxidation products for measuring global oxidative stress in vivo
Introduction To examine the reliability, sensitivity, and specificity of fluorescent oxidation products (FlOPs; markers of global oxidative damage) for measuring global oxidative stress. Methods To improve FlOP measurement reliability, we mixed plasma samples with the extractant at eight ratios and...
Saved in:
Main Authors: | , , , , , , , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Taylor & Francis Group
2024-12-01
|
Series: | All Life |
Subjects: | |
Online Access: | http://dx.doi.org/10.1080/26895293.2024.2381700 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
_version_ | 1832593472579698688 |
---|---|
author | Bing Liang Juan Zhang Xue Shen Xiaohua Zhang Ann M. Vuong Linghua Yang Xinyan Shi Xueru Ge Huan He Tong Liu Shuman Yang |
author_facet | Bing Liang Juan Zhang Xue Shen Xiaohua Zhang Ann M. Vuong Linghua Yang Xinyan Shi Xueru Ge Huan He Tong Liu Shuman Yang |
author_sort | Bing Liang |
collection | DOAJ |
description | Introduction To examine the reliability, sensitivity, and specificity of fluorescent oxidation products (FlOPs; markers of global oxidative damage) for measuring global oxidative stress. Methods To improve FlOP measurement reliability, we mixed plasma samples with the extractant at eight ratios and measured FlOPs with a fluorescent microplate reader (excitation/emission wavelengths 320/420 nm denoted FlOP_320; 360/420 nm [FlOP_360]; and 400/475 nm [FlOP_400]). In a human study, we examined the reliability of an improved FlOP measurement. In an animal study, we examined the sensitivity and specificity of FlOPs for measuring D-galactose induced global oxidative stress. Results At a 1:20 (plasma/extractant) mixture ratio, the overall inter-/intra-assay coefficients of variation (CV) for FlOP measurements among healthy and coronary heart disease participants were <3.6%/<2.7% and <4.4%/<2.0%, respectively. On day 30 of the animal experiment, the Pearson correlations (r) of FlOP_320 and FlOP_360 with D-galactose dose were 0.816 and 0.801, respectively, which were 3-12 times higher than those of malondialdehyde (0.183), 8-hydroxyguanosine (0.157), pentosidine (0.254), and nitrotyrosine (0.068) for measuring D-galactose-induced oxidative damage. FlOP_360 (r = 0.225, P = 0.045), but not FlOP_320 and FlOP_400, were significantly correlated with c-reactive protein, a marker of inflammation. Conclusions FlOP_320 are reliable, sensitive and specific markers for measuring global oxidative stress. Key policy highlights Fluorescent oxidation products (FlOPs) are a reliable marker of oxidative stress FlOPs at 320/420 nm are more sensitive than traditional markers FlOP at 320/420 nm did not reflect inflammation as quantified by c-reactive protein |
format | Article |
id | doaj-art-6550065ffd3b4499a3539ad1a90332b5 |
institution | Kabale University |
issn | 2689-5307 |
language | English |
publishDate | 2024-12-01 |
publisher | Taylor & Francis Group |
record_format | Article |
series | All Life |
spelling | doaj-art-6550065ffd3b4499a3539ad1a90332b52025-01-20T14:38:00ZengTaylor & Francis GroupAll Life2689-53072024-12-01170110.1080/26895293.2024.23817002381700The reliability, sensitivity and specificity of fluorescent oxidation products for measuring global oxidative stress in vivoBing Liang0Juan Zhang1Xue Shen2Xiaohua Zhang3Ann M. Vuong4Linghua Yang5Xinyan Shi6Xueru Ge7Huan He8Tong Liu9Shuman Yang10The First Affiliated Hospital of Jinzhou Medical UniversityJilin UniversityJilin UniversityJilin UniversityUniversity of NevadaJilin UniversityJilin UniversityJilin UniversityJilin UniversityJilin UniversityThe First Affiliated Hospital of Jinzhou Medical UniversityIntroduction To examine the reliability, sensitivity, and specificity of fluorescent oxidation products (FlOPs; markers of global oxidative damage) for measuring global oxidative stress. Methods To improve FlOP measurement reliability, we mixed plasma samples with the extractant at eight ratios and measured FlOPs with a fluorescent microplate reader (excitation/emission wavelengths 320/420 nm denoted FlOP_320; 360/420 nm [FlOP_360]; and 400/475 nm [FlOP_400]). In a human study, we examined the reliability of an improved FlOP measurement. In an animal study, we examined the sensitivity and specificity of FlOPs for measuring D-galactose induced global oxidative stress. Results At a 1:20 (plasma/extractant) mixture ratio, the overall inter-/intra-assay coefficients of variation (CV) for FlOP measurements among healthy and coronary heart disease participants were <3.6%/<2.7% and <4.4%/<2.0%, respectively. On day 30 of the animal experiment, the Pearson correlations (r) of FlOP_320 and FlOP_360 with D-galactose dose were 0.816 and 0.801, respectively, which were 3-12 times higher than those of malondialdehyde (0.183), 8-hydroxyguanosine (0.157), pentosidine (0.254), and nitrotyrosine (0.068) for measuring D-galactose-induced oxidative damage. FlOP_360 (r = 0.225, P = 0.045), but not FlOP_320 and FlOP_400, were significantly correlated with c-reactive protein, a marker of inflammation. Conclusions FlOP_320 are reliable, sensitive and specific markers for measuring global oxidative stress. Key policy highlights Fluorescent oxidation products (FlOPs) are a reliable marker of oxidative stress FlOPs at 320/420 nm are more sensitive than traditional markers FlOP at 320/420 nm did not reflect inflammation as quantified by c-reactive proteinhttp://dx.doi.org/10.1080/26895293.2024.2381700oxidative stressfluorescent oxidation productsreliabilitysensitivityspecificitylaboratory factors |
spellingShingle | Bing Liang Juan Zhang Xue Shen Xiaohua Zhang Ann M. Vuong Linghua Yang Xinyan Shi Xueru Ge Huan He Tong Liu Shuman Yang The reliability, sensitivity and specificity of fluorescent oxidation products for measuring global oxidative stress in vivo All Life oxidative stress fluorescent oxidation products reliability sensitivity specificity laboratory factors |
title | The reliability, sensitivity and specificity of fluorescent oxidation products for measuring global oxidative stress in vivo |
title_full | The reliability, sensitivity and specificity of fluorescent oxidation products for measuring global oxidative stress in vivo |
title_fullStr | The reliability, sensitivity and specificity of fluorescent oxidation products for measuring global oxidative stress in vivo |
title_full_unstemmed | The reliability, sensitivity and specificity of fluorescent oxidation products for measuring global oxidative stress in vivo |
title_short | The reliability, sensitivity and specificity of fluorescent oxidation products for measuring global oxidative stress in vivo |
title_sort | reliability sensitivity and specificity of fluorescent oxidation products for measuring global oxidative stress in vivo |
topic | oxidative stress fluorescent oxidation products reliability sensitivity specificity laboratory factors |
url | http://dx.doi.org/10.1080/26895293.2024.2381700 |
work_keys_str_mv | AT bingliang thereliabilitysensitivityandspecificityoffluorescentoxidationproductsformeasuringglobaloxidativestressinvivo AT juanzhang thereliabilitysensitivityandspecificityoffluorescentoxidationproductsformeasuringglobaloxidativestressinvivo AT xueshen thereliabilitysensitivityandspecificityoffluorescentoxidationproductsformeasuringglobaloxidativestressinvivo AT xiaohuazhang thereliabilitysensitivityandspecificityoffluorescentoxidationproductsformeasuringglobaloxidativestressinvivo AT annmvuong thereliabilitysensitivityandspecificityoffluorescentoxidationproductsformeasuringglobaloxidativestressinvivo AT linghuayang thereliabilitysensitivityandspecificityoffluorescentoxidationproductsformeasuringglobaloxidativestressinvivo AT xinyanshi thereliabilitysensitivityandspecificityoffluorescentoxidationproductsformeasuringglobaloxidativestressinvivo AT xueruge thereliabilitysensitivityandspecificityoffluorescentoxidationproductsformeasuringglobaloxidativestressinvivo AT huanhe thereliabilitysensitivityandspecificityoffluorescentoxidationproductsformeasuringglobaloxidativestressinvivo AT tongliu thereliabilitysensitivityandspecificityoffluorescentoxidationproductsformeasuringglobaloxidativestressinvivo AT shumanyang thereliabilitysensitivityandspecificityoffluorescentoxidationproductsformeasuringglobaloxidativestressinvivo AT bingliang reliabilitysensitivityandspecificityoffluorescentoxidationproductsformeasuringglobaloxidativestressinvivo AT juanzhang reliabilitysensitivityandspecificityoffluorescentoxidationproductsformeasuringglobaloxidativestressinvivo AT xueshen reliabilitysensitivityandspecificityoffluorescentoxidationproductsformeasuringglobaloxidativestressinvivo AT xiaohuazhang reliabilitysensitivityandspecificityoffluorescentoxidationproductsformeasuringglobaloxidativestressinvivo AT annmvuong reliabilitysensitivityandspecificityoffluorescentoxidationproductsformeasuringglobaloxidativestressinvivo AT linghuayang reliabilitysensitivityandspecificityoffluorescentoxidationproductsformeasuringglobaloxidativestressinvivo AT xinyanshi reliabilitysensitivityandspecificityoffluorescentoxidationproductsformeasuringglobaloxidativestressinvivo AT xueruge reliabilitysensitivityandspecificityoffluorescentoxidationproductsformeasuringglobaloxidativestressinvivo AT huanhe reliabilitysensitivityandspecificityoffluorescentoxidationproductsformeasuringglobaloxidativestressinvivo AT tongliu reliabilitysensitivityandspecificityoffluorescentoxidationproductsformeasuringglobaloxidativestressinvivo AT shumanyang reliabilitysensitivityandspecificityoffluorescentoxidationproductsformeasuringglobaloxidativestressinvivo |