DAMPING OF VIBRATIONS IN INTERCHANGE POWER
The paper considers damping of vibrations in interchange power of interconnecting transmission lines. Influence of natural and supplementary regulation parameters on the character of transient process is shown in the paper.The paper contains recommendations for elimination of maximum interchange pow...
Saved in:
Main Authors: | , |
---|---|
Format: | Article |
Language: | Russian |
Published: |
Belarusian National Technical University
2005-04-01
|
Series: | Известия высших учебных заведений и энергетических объединенний СНГ: Энергетика |
Online Access: | https://energy.bntu.by/jour/article/view/918 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
_version_ | 1832543709313368064 |
---|---|
author | G. M. Pavlov H. T. Rishague |
author_facet | G. M. Pavlov H. T. Rishague |
author_sort | G. M. Pavlov |
collection | DOAJ |
description | The paper considers damping of vibrations in interchange power of interconnecting transmission lines. Influence of natural and supplementary regulation parameters on the character of transient process is shown in the paper.The paper contains recommendations for elimination of maximum interchange power deviation in the transient process. |
format | Article |
id | doaj-art-654d3d829e71475ba40a5f8976dc7d39 |
institution | Kabale University |
issn | 1029-7448 2414-0341 |
language | Russian |
publishDate | 2005-04-01 |
publisher | Belarusian National Technical University |
record_format | Article |
series | Известия высших учебных заведений и энергетических объединенний СНГ: Энергетика |
spelling | doaj-art-654d3d829e71475ba40a5f8976dc7d392025-02-03T11:34:21ZrusBelarusian National Technical UniversityИзвестия высших учебных заведений и энергетических объединенний СНГ: Энергетика1029-74482414-03412005-04-0102510895DAMPING OF VIBRATIONS IN INTERCHANGE POWERG. M. Pavlov0H. T. Rishague1Saint Petersburg State Polytechnic UniversitySaint Petersburg State Polytechnic UniversityThe paper considers damping of vibrations in interchange power of interconnecting transmission lines. Influence of natural and supplementary regulation parameters on the character of transient process is shown in the paper.The paper contains recommendations for elimination of maximum interchange power deviation in the transient process.https://energy.bntu.by/jour/article/view/918 |
spellingShingle | G. M. Pavlov H. T. Rishague DAMPING OF VIBRATIONS IN INTERCHANGE POWER Известия высших учебных заведений и энергетических объединенний СНГ: Энергетика |
title | DAMPING OF VIBRATIONS IN INTERCHANGE POWER |
title_full | DAMPING OF VIBRATIONS IN INTERCHANGE POWER |
title_fullStr | DAMPING OF VIBRATIONS IN INTERCHANGE POWER |
title_full_unstemmed | DAMPING OF VIBRATIONS IN INTERCHANGE POWER |
title_short | DAMPING OF VIBRATIONS IN INTERCHANGE POWER |
title_sort | damping of vibrations in interchange power |
url | https://energy.bntu.by/jour/article/view/918 |
work_keys_str_mv | AT gmpavlov dampingofvibrationsininterchangepower AT htrishague dampingofvibrationsininterchangepower |