Micro silica bead scintillators for the relative dosimetry of a stereotactic radiosurgery unit
This work describes the procedure of using Micro Silica Beads (MSBs) to verify the output factors and profiles of a stereotactic radiosurgery unit. MSBs have shown acceptable dosimetric accuracy for measurement of Detector Output Ratios (DORs) and shot profiles, down to a full width at half maximum...
Saved in:
Main Authors: | , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Elsevier
2025-01-01
|
Series: | Physics and Imaging in Radiation Oncology |
Subjects: | |
Online Access: | http://www.sciencedirect.com/science/article/pii/S2405631625000144 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
_version_ | 1832576474784202752 |
---|---|
author | Chris J. Stepanek Jack D. Aylward Ronald Hartley-Davies Lucy Winch |
author_facet | Chris J. Stepanek Jack D. Aylward Ronald Hartley-Davies Lucy Winch |
author_sort | Chris J. Stepanek |
collection | DOAJ |
description | This work describes the procedure of using Micro Silica Beads (MSBs) to verify the output factors and profiles of a stereotactic radiosurgery unit. MSBs have shown acceptable dosimetric accuracy for measurement of Detector Output Ratios (DORs) and shot profiles, down to a full width at half maximum (FWHM) of 5 mm. DORs measured with MSBs were within 1.5 % of radiochromic film, and 3 % of a microdiamond detector. Measured FWHM were within 0.2 mm of planning system and radiochromic film. MSBs can be used as an effective substitute to radiochromic film for measurement of shot profiles and DORs. |
format | Article |
id | doaj-art-6298dfd39fbc46a99c7770efd65d8f53 |
institution | Kabale University |
issn | 2405-6316 |
language | English |
publishDate | 2025-01-01 |
publisher | Elsevier |
record_format | Article |
series | Physics and Imaging in Radiation Oncology |
spelling | doaj-art-6298dfd39fbc46a99c7770efd65d8f532025-01-31T05:11:55ZengElsevierPhysics and Imaging in Radiation Oncology2405-63162025-01-0133100709Micro silica bead scintillators for the relative dosimetry of a stereotactic radiosurgery unitChris J. Stepanek0Jack D. Aylward1Ronald Hartley-Davies2Lucy Winch3Department of Medical Physics and Bioengineering, Bristol Haematology & Oncology Centre, University Hospitals Bristol & Weston NHS Foundation Trust, Horfield Road, Bristol BS2 8ED, United KingdomDepartment of Medical Physics and Bioengineering, Bristol Haematology & Oncology Centre, University Hospitals Bristol & Weston NHS Foundation Trust, Horfield Road, Bristol BS2 8ED, United Kingdom; Medical Physics, School of Applied Sciences, University of the West of England, Bristol, United KingdomDepartment of Medical Physics and Bioengineering, Bristol Haematology & Oncology Centre, University Hospitals Bristol & Weston NHS Foundation Trust, Horfield Road, Bristol BS2 8ED, United KingdomDepartment of Medical Physics and Bioengineering, Bristol Haematology & Oncology Centre, University Hospitals Bristol & Weston NHS Foundation Trust, Horfield Road, Bristol BS2 8ED, United Kingdom; Corresponding author.This work describes the procedure of using Micro Silica Beads (MSBs) to verify the output factors and profiles of a stereotactic radiosurgery unit. MSBs have shown acceptable dosimetric accuracy for measurement of Detector Output Ratios (DORs) and shot profiles, down to a full width at half maximum (FWHM) of 5 mm. DORs measured with MSBs were within 1.5 % of radiochromic film, and 3 % of a microdiamond detector. Measured FWHM were within 0.2 mm of planning system and radiochromic film. MSBs can be used as an effective substitute to radiochromic film for measurement of shot profiles and DORs.http://www.sciencedirect.com/science/article/pii/S2405631625000144Micro Silica BeadsGamma Knife relative dosimetryDetector Output RatiosShot Profiles |
spellingShingle | Chris J. Stepanek Jack D. Aylward Ronald Hartley-Davies Lucy Winch Micro silica bead scintillators for the relative dosimetry of a stereotactic radiosurgery unit Physics and Imaging in Radiation Oncology Micro Silica Beads Gamma Knife relative dosimetry Detector Output Ratios Shot Profiles |
title | Micro silica bead scintillators for the relative dosimetry of a stereotactic radiosurgery unit |
title_full | Micro silica bead scintillators for the relative dosimetry of a stereotactic radiosurgery unit |
title_fullStr | Micro silica bead scintillators for the relative dosimetry of a stereotactic radiosurgery unit |
title_full_unstemmed | Micro silica bead scintillators for the relative dosimetry of a stereotactic radiosurgery unit |
title_short | Micro silica bead scintillators for the relative dosimetry of a stereotactic radiosurgery unit |
title_sort | micro silica bead scintillators for the relative dosimetry of a stereotactic radiosurgery unit |
topic | Micro Silica Beads Gamma Knife relative dosimetry Detector Output Ratios Shot Profiles |
url | http://www.sciencedirect.com/science/article/pii/S2405631625000144 |
work_keys_str_mv | AT chrisjstepanek microsilicabeadscintillatorsfortherelativedosimetryofastereotacticradiosurgeryunit AT jackdaylward microsilicabeadscintillatorsfortherelativedosimetryofastereotacticradiosurgeryunit AT ronaldhartleydavies microsilicabeadscintillatorsfortherelativedosimetryofastereotacticradiosurgeryunit AT lucywinch microsilicabeadscintillatorsfortherelativedosimetryofastereotacticradiosurgeryunit |