Micro silica bead scintillators for the relative dosimetry of a stereotactic radiosurgery unit

This work describes the procedure of using Micro Silica Beads (MSBs) to verify the output factors and profiles of a stereotactic radiosurgery unit. MSBs have shown acceptable dosimetric accuracy for measurement of Detector Output Ratios (DORs) and shot profiles, down to a full width at half maximum...

Full description

Saved in:
Bibliographic Details
Main Authors: Chris J. Stepanek, Jack D. Aylward, Ronald Hartley-Davies, Lucy Winch
Format: Article
Language:English
Published: Elsevier 2025-01-01
Series:Physics and Imaging in Radiation Oncology
Subjects:
Online Access:http://www.sciencedirect.com/science/article/pii/S2405631625000144
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1832576474784202752
author Chris J. Stepanek
Jack D. Aylward
Ronald Hartley-Davies
Lucy Winch
author_facet Chris J. Stepanek
Jack D. Aylward
Ronald Hartley-Davies
Lucy Winch
author_sort Chris J. Stepanek
collection DOAJ
description This work describes the procedure of using Micro Silica Beads (MSBs) to verify the output factors and profiles of a stereotactic radiosurgery unit. MSBs have shown acceptable dosimetric accuracy for measurement of Detector Output Ratios (DORs) and shot profiles, down to a full width at half maximum (FWHM) of 5 mm. DORs measured with MSBs were within 1.5 % of radiochromic film, and 3 % of a microdiamond detector. Measured FWHM were within 0.2 mm of planning system and radiochromic film. MSBs can be used as an effective substitute to radiochromic film for measurement of shot profiles and DORs.
format Article
id doaj-art-6298dfd39fbc46a99c7770efd65d8f53
institution Kabale University
issn 2405-6316
language English
publishDate 2025-01-01
publisher Elsevier
record_format Article
series Physics and Imaging in Radiation Oncology
spelling doaj-art-6298dfd39fbc46a99c7770efd65d8f532025-01-31T05:11:55ZengElsevierPhysics and Imaging in Radiation Oncology2405-63162025-01-0133100709Micro silica bead scintillators for the relative dosimetry of a stereotactic radiosurgery unitChris J. Stepanek0Jack D. Aylward1Ronald Hartley-Davies2Lucy Winch3Department of Medical Physics and Bioengineering, Bristol Haematology & Oncology Centre, University Hospitals Bristol & Weston NHS Foundation Trust, Horfield Road, Bristol BS2 8ED, United KingdomDepartment of Medical Physics and Bioengineering, Bristol Haematology & Oncology Centre, University Hospitals Bristol & Weston NHS Foundation Trust, Horfield Road, Bristol BS2 8ED, United Kingdom; Medical Physics, School of Applied Sciences, University of the West of England, Bristol, United KingdomDepartment of Medical Physics and Bioengineering, Bristol Haematology & Oncology Centre, University Hospitals Bristol & Weston NHS Foundation Trust, Horfield Road, Bristol BS2 8ED, United KingdomDepartment of Medical Physics and Bioengineering, Bristol Haematology & Oncology Centre, University Hospitals Bristol & Weston NHS Foundation Trust, Horfield Road, Bristol BS2 8ED, United Kingdom; Corresponding author.This work describes the procedure of using Micro Silica Beads (MSBs) to verify the output factors and profiles of a stereotactic radiosurgery unit. MSBs have shown acceptable dosimetric accuracy for measurement of Detector Output Ratios (DORs) and shot profiles, down to a full width at half maximum (FWHM) of 5 mm. DORs measured with MSBs were within 1.5 % of radiochromic film, and 3 % of a microdiamond detector. Measured FWHM were within 0.2 mm of planning system and radiochromic film. MSBs can be used as an effective substitute to radiochromic film for measurement of shot profiles and DORs.http://www.sciencedirect.com/science/article/pii/S2405631625000144Micro Silica BeadsGamma Knife relative dosimetryDetector Output RatiosShot Profiles
spellingShingle Chris J. Stepanek
Jack D. Aylward
Ronald Hartley-Davies
Lucy Winch
Micro silica bead scintillators for the relative dosimetry of a stereotactic radiosurgery unit
Physics and Imaging in Radiation Oncology
Micro Silica Beads
Gamma Knife relative dosimetry
Detector Output Ratios
Shot Profiles
title Micro silica bead scintillators for the relative dosimetry of a stereotactic radiosurgery unit
title_full Micro silica bead scintillators for the relative dosimetry of a stereotactic radiosurgery unit
title_fullStr Micro silica bead scintillators for the relative dosimetry of a stereotactic radiosurgery unit
title_full_unstemmed Micro silica bead scintillators for the relative dosimetry of a stereotactic radiosurgery unit
title_short Micro silica bead scintillators for the relative dosimetry of a stereotactic radiosurgery unit
title_sort micro silica bead scintillators for the relative dosimetry of a stereotactic radiosurgery unit
topic Micro Silica Beads
Gamma Knife relative dosimetry
Detector Output Ratios
Shot Profiles
url http://www.sciencedirect.com/science/article/pii/S2405631625000144
work_keys_str_mv AT chrisjstepanek microsilicabeadscintillatorsfortherelativedosimetryofastereotacticradiosurgeryunit
AT jackdaylward microsilicabeadscintillatorsfortherelativedosimetryofastereotacticradiosurgeryunit
AT ronaldhartleydavies microsilicabeadscintillatorsfortherelativedosimetryofastereotacticradiosurgeryunit
AT lucywinch microsilicabeadscintillatorsfortherelativedosimetryofastereotacticradiosurgeryunit