Stress distribution of four implant supported overdentures with tilted standard-sized implants and mini implants
Purpose: The goal of the current study is to evaluate the stress distribution when tilted implants and mini-implants are used to support a mandibular overdenture.Materials and Methods: Three-dimensional (3D) finite element models of mandibular overdentures were established using four, axial, standar...