A Unified Power Quality Conditioner for Feeder Reconfiguration and Setting to Minimize the Power Loss and Improve Voltage Profile
Using devices such as unified power quality conditioners (UPQCs) in distribution networks seems essential for higher electricity quality. Moreover, distribution network reconfiguration is a suitable model for improving network characteristics, including loss reduction and voltage increase for distri...
Saved in:
Main Authors: | , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Wiley
2022-01-01
|
Series: | Complexity |
Online Access: | http://dx.doi.org/10.1155/2022/5742846 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
_version_ | 1832548605044457472 |
---|---|
author | Zhigao Huang Farid Shahbaazy Afshin Davarpanah |
author_facet | Zhigao Huang Farid Shahbaazy Afshin Davarpanah |
author_sort | Zhigao Huang |
collection | DOAJ |
description | Using devices such as unified power quality conditioners (UPQCs) in distribution networks seems essential for higher electricity quality. Moreover, distribution network reconfiguration is a suitable model for improving network characteristics, including loss reduction and voltage increase for distribution networks, and is widely used in this era. Here, the study discusses the rechanging of distribution networks for UPQC via proposing an appropriate model for it. In addition to the optimum structure of distribution networks, the most appropriate branch where UPQC must be located and the most appropriate reactive power size with which series and shunt filters must be injected into the grid are determined. The simulations have been applied on two 69- and 84-standard-bus networks. The results of the simulations indicate much power loss reduction and much voltage increase in the presence of UPQC compensators. |
format | Article |
id | doaj-art-61dabd228adb496797d21cda164143cf |
institution | Kabale University |
issn | 1099-0526 |
language | English |
publishDate | 2022-01-01 |
publisher | Wiley |
record_format | Article |
series | Complexity |
spelling | doaj-art-61dabd228adb496797d21cda164143cf2025-02-03T06:13:30ZengWileyComplexity1099-05262022-01-01202210.1155/2022/5742846A Unified Power Quality Conditioner for Feeder Reconfiguration and Setting to Minimize the Power Loss and Improve Voltage ProfileZhigao Huang0Farid Shahbaazy1Afshin Davarpanah2Wuhan Railway Vocational College TechnologyDepartment of Electrical EngineeringYoung Elite ResearchersUsing devices such as unified power quality conditioners (UPQCs) in distribution networks seems essential for higher electricity quality. Moreover, distribution network reconfiguration is a suitable model for improving network characteristics, including loss reduction and voltage increase for distribution networks, and is widely used in this era. Here, the study discusses the rechanging of distribution networks for UPQC via proposing an appropriate model for it. In addition to the optimum structure of distribution networks, the most appropriate branch where UPQC must be located and the most appropriate reactive power size with which series and shunt filters must be injected into the grid are determined. The simulations have been applied on two 69- and 84-standard-bus networks. The results of the simulations indicate much power loss reduction and much voltage increase in the presence of UPQC compensators.http://dx.doi.org/10.1155/2022/5742846 |
spellingShingle | Zhigao Huang Farid Shahbaazy Afshin Davarpanah A Unified Power Quality Conditioner for Feeder Reconfiguration and Setting to Minimize the Power Loss and Improve Voltage Profile Complexity |
title | A Unified Power Quality Conditioner for Feeder Reconfiguration and Setting to Minimize the Power Loss and Improve Voltage Profile |
title_full | A Unified Power Quality Conditioner for Feeder Reconfiguration and Setting to Minimize the Power Loss and Improve Voltage Profile |
title_fullStr | A Unified Power Quality Conditioner for Feeder Reconfiguration and Setting to Minimize the Power Loss and Improve Voltage Profile |
title_full_unstemmed | A Unified Power Quality Conditioner for Feeder Reconfiguration and Setting to Minimize the Power Loss and Improve Voltage Profile |
title_short | A Unified Power Quality Conditioner for Feeder Reconfiguration and Setting to Minimize the Power Loss and Improve Voltage Profile |
title_sort | unified power quality conditioner for feeder reconfiguration and setting to minimize the power loss and improve voltage profile |
url | http://dx.doi.org/10.1155/2022/5742846 |
work_keys_str_mv | AT zhigaohuang aunifiedpowerqualityconditionerforfeederreconfigurationandsettingtominimizethepowerlossandimprovevoltageprofile AT faridshahbaazy aunifiedpowerqualityconditionerforfeederreconfigurationandsettingtominimizethepowerlossandimprovevoltageprofile AT afshindavarpanah aunifiedpowerqualityconditionerforfeederreconfigurationandsettingtominimizethepowerlossandimprovevoltageprofile AT zhigaohuang unifiedpowerqualityconditionerforfeederreconfigurationandsettingtominimizethepowerlossandimprovevoltageprofile AT faridshahbaazy unifiedpowerqualityconditionerforfeederreconfigurationandsettingtominimizethepowerlossandimprovevoltageprofile AT afshindavarpanah unifiedpowerqualityconditionerforfeederreconfigurationandsettingtominimizethepowerlossandimprovevoltageprofile |