Research on Noise Reduction Scheme of Heat Pump Unit in a Square

Heat pump unit is a host device located in the central air-conditioning terminal, providing cold and hot water. Heat pump unit has the advantages of energy saving, environmental protection, easy maintenance, and so on. It is adopted to solve the problems of refrigeration and heating in ventilation a...

Full description

Saved in:
Bibliographic Details
Main Authors: Xueyong Zhang, Yuanyuan Hu, Shengyuan Geng, Qianyong Hu, Huanbao Wang
Format: Article
Language:English
Published: Wiley 2020-01-01
Series:Journal of Chemistry
Online Access:http://dx.doi.org/10.1155/2020/1237034
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1832566279321419776
author Xueyong Zhang
Yuanyuan Hu
Shengyuan Geng
Qianyong Hu
Huanbao Wang
author_facet Xueyong Zhang
Yuanyuan Hu
Shengyuan Geng
Qianyong Hu
Huanbao Wang
author_sort Xueyong Zhang
collection DOAJ
description Heat pump unit is a host device located in the central air-conditioning terminal, providing cold and hot water. Heat pump unit has the advantages of energy saving, environmental protection, easy maintenance, and so on. It is adopted to solve the problems of refrigeration and heating in ventilation and air conditioning from many engineering projects in China. When the equipment is turned on, however, the high noise generated by the heat pump unit has a very negative impact on the life and work of the surrounding residents. Therefore, noise reduction is needed to improve the environment quality. In this paper, the noise of the air-cooled heat pump unit of the square area in Shanghai was detected, the noise source was analyzed, and the corresponding noise reduction scheme was proposed. After the completion of the scheme, measurements indicate that A-weighted sound pressure level is less than or equal to 60 dB (A) during the day and less than or equal to 50 dB (A) at night, which meets the relevant national noise limit emission standards and conforms to the second-class quality standard of the acoustic environment.
format Article
id doaj-art-6196f06f3f40405abd0a284e1607c5ce
institution Kabale University
issn 2090-9063
2090-9071
language English
publishDate 2020-01-01
publisher Wiley
record_format Article
series Journal of Chemistry
spelling doaj-art-6196f06f3f40405abd0a284e1607c5ce2025-02-03T01:04:38ZengWileyJournal of Chemistry2090-90632090-90712020-01-01202010.1155/2020/12370341237034Research on Noise Reduction Scheme of Heat Pump Unit in a SquareXueyong Zhang0Yuanyuan Hu1Shengyuan Geng2Qianyong Hu3Huanbao Wang4School of Mathematics and Physics, Institute of Acoustics, Anhui Jianzhu University, Hefei 230601, ChinaSchool of Mathematics and Physics, Institute of Acoustics, Anhui Jianzhu University, Hefei 230601, ChinaAnhui Province Key Laboratory of Intelligent Building & Building Energy Saving, Hefei 230022, ChinaSchool of Mathematics and Physics, Institute of Acoustics, Anhui Jianzhu University, Hefei 230601, ChinaSchool of Mathematics and Physics, Institute of Acoustics, Anhui Jianzhu University, Hefei 230601, ChinaHeat pump unit is a host device located in the central air-conditioning terminal, providing cold and hot water. Heat pump unit has the advantages of energy saving, environmental protection, easy maintenance, and so on. It is adopted to solve the problems of refrigeration and heating in ventilation and air conditioning from many engineering projects in China. When the equipment is turned on, however, the high noise generated by the heat pump unit has a very negative impact on the life and work of the surrounding residents. Therefore, noise reduction is needed to improve the environment quality. In this paper, the noise of the air-cooled heat pump unit of the square area in Shanghai was detected, the noise source was analyzed, and the corresponding noise reduction scheme was proposed. After the completion of the scheme, measurements indicate that A-weighted sound pressure level is less than or equal to 60 dB (A) during the day and less than or equal to 50 dB (A) at night, which meets the relevant national noise limit emission standards and conforms to the second-class quality standard of the acoustic environment.http://dx.doi.org/10.1155/2020/1237034
spellingShingle Xueyong Zhang
Yuanyuan Hu
Shengyuan Geng
Qianyong Hu
Huanbao Wang
Research on Noise Reduction Scheme of Heat Pump Unit in a Square
Journal of Chemistry
title Research on Noise Reduction Scheme of Heat Pump Unit in a Square
title_full Research on Noise Reduction Scheme of Heat Pump Unit in a Square
title_fullStr Research on Noise Reduction Scheme of Heat Pump Unit in a Square
title_full_unstemmed Research on Noise Reduction Scheme of Heat Pump Unit in a Square
title_short Research on Noise Reduction Scheme of Heat Pump Unit in a Square
title_sort research on noise reduction scheme of heat pump unit in a square
url http://dx.doi.org/10.1155/2020/1237034
work_keys_str_mv AT xueyongzhang researchonnoisereductionschemeofheatpumpunitinasquare
AT yuanyuanhu researchonnoisereductionschemeofheatpumpunitinasquare
AT shengyuangeng researchonnoisereductionschemeofheatpumpunitinasquare
AT qianyonghu researchonnoisereductionschemeofheatpumpunitinasquare
AT huanbaowang researchonnoisereductionschemeofheatpumpunitinasquare