Real and Pseudoaccommodation in Accommodative Lenses

In the attempt to manage presbyopia, different intraocular lens designs have been proposed such as monofocal IOLs with monovision or multifocal IOLs. Even though the lenses mentioned offer satisfactory visual results, contemporary ophthalmology has not completely answered the presbyopic dilemma by s...

Full description

Saved in:
Bibliographic Details
Main Authors: Ioannis G. Pallikaris, Georgios A. Kontadakis, Dimitra M. Portaliou
Format: Article
Language:English
Published: Wiley 2011-01-01
Series:Journal of Ophthalmology
Online Access:http://dx.doi.org/10.1155/2011/284961
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1832567517521903616
author Ioannis G. Pallikaris
Georgios A. Kontadakis
Dimitra M. Portaliou
author_facet Ioannis G. Pallikaris
Georgios A. Kontadakis
Dimitra M. Portaliou
author_sort Ioannis G. Pallikaris
collection DOAJ
description In the attempt to manage presbyopia, different intraocular lens designs have been proposed such as monofocal IOLs with monovision or multifocal IOLs. Even though the lenses mentioned offer satisfactory visual results, contemporary ophthalmology has not completely answered the presbyopic dilemma by simulating the accommodative properties of the crystalline lens itself. Accommodative IOLs were designed to fill this gap and provide satisfactory vision for all distances by restoring some degree of “pseudoaccommodation.” Pseudo accommodative capability can be linked to monofocal IOL’s as well but the results are not satisfactory enough to fully support unaided near vision. Pseudoaccommodation is a complex phenomenon that can be attributed to several static (i.e., pupil size, against-the-rule cylindrical refractive error, multifocality of the cornea) and dynamic (i.e., anterior movement of the implant itself) factors. Objective measurement of the accommodative capability offered by the accommodative IOLs is extremely difficult to obtain, and different methods such as autorefractometers, retinoscopy, and ultrasound imaging during accommodative effort, ray tracing, or pharmacological stimulation have been developed but the results are sometimes inconsistent. Despite the difficulties in measuring accommodation, accommodative IOLs represent the future in the attempt to successfully “cure” presbyopia.
format Article
id doaj-art-61373d8c53c3456285fdba09152c898d
institution Kabale University
issn 2090-004X
2090-0058
language English
publishDate 2011-01-01
publisher Wiley
record_format Article
series Journal of Ophthalmology
spelling doaj-art-61373d8c53c3456285fdba09152c898d2025-02-03T01:01:13ZengWileyJournal of Ophthalmology2090-004X2090-00582011-01-01201110.1155/2011/284961284961Real and Pseudoaccommodation in Accommodative LensesIoannis G. Pallikaris0Georgios A. Kontadakis1Dimitra M. Portaliou2Institute of Vision and Optics (IVO), University of Crete, Medical School, Heraklion, 71003 Crete, GreeceInstitute of Vision and Optics (IVO), University of Crete, Medical School, Heraklion, 71003 Crete, GreeceInstitute of Vision and Optics (IVO), University of Crete, Medical School, Heraklion, 71003 Crete, GreeceIn the attempt to manage presbyopia, different intraocular lens designs have been proposed such as monofocal IOLs with monovision or multifocal IOLs. Even though the lenses mentioned offer satisfactory visual results, contemporary ophthalmology has not completely answered the presbyopic dilemma by simulating the accommodative properties of the crystalline lens itself. Accommodative IOLs were designed to fill this gap and provide satisfactory vision for all distances by restoring some degree of “pseudoaccommodation.” Pseudo accommodative capability can be linked to monofocal IOL’s as well but the results are not satisfactory enough to fully support unaided near vision. Pseudoaccommodation is a complex phenomenon that can be attributed to several static (i.e., pupil size, against-the-rule cylindrical refractive error, multifocality of the cornea) and dynamic (i.e., anterior movement of the implant itself) factors. Objective measurement of the accommodative capability offered by the accommodative IOLs is extremely difficult to obtain, and different methods such as autorefractometers, retinoscopy, and ultrasound imaging during accommodative effort, ray tracing, or pharmacological stimulation have been developed but the results are sometimes inconsistent. Despite the difficulties in measuring accommodation, accommodative IOLs represent the future in the attempt to successfully “cure” presbyopia.http://dx.doi.org/10.1155/2011/284961
spellingShingle Ioannis G. Pallikaris
Georgios A. Kontadakis
Dimitra M. Portaliou
Real and Pseudoaccommodation in Accommodative Lenses
Journal of Ophthalmology
title Real and Pseudoaccommodation in Accommodative Lenses
title_full Real and Pseudoaccommodation in Accommodative Lenses
title_fullStr Real and Pseudoaccommodation in Accommodative Lenses
title_full_unstemmed Real and Pseudoaccommodation in Accommodative Lenses
title_short Real and Pseudoaccommodation in Accommodative Lenses
title_sort real and pseudoaccommodation in accommodative lenses
url http://dx.doi.org/10.1155/2011/284961
work_keys_str_mv AT ioannisgpallikaris realandpseudoaccommodationinaccommodativelenses
AT georgiosakontadakis realandpseudoaccommodationinaccommodativelenses
AT dimitramportaliou realandpseudoaccommodationinaccommodativelenses