Real and Pseudoaccommodation in Accommodative Lenses
In the attempt to manage presbyopia, different intraocular lens designs have been proposed such as monofocal IOLs with monovision or multifocal IOLs. Even though the lenses mentioned offer satisfactory visual results, contemporary ophthalmology has not completely answered the presbyopic dilemma by s...
Saved in:
Main Authors: | , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Wiley
2011-01-01
|
Series: | Journal of Ophthalmology |
Online Access: | http://dx.doi.org/10.1155/2011/284961 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
_version_ | 1832567517521903616 |
---|---|
author | Ioannis G. Pallikaris Georgios A. Kontadakis Dimitra M. Portaliou |
author_facet | Ioannis G. Pallikaris Georgios A. Kontadakis Dimitra M. Portaliou |
author_sort | Ioannis G. Pallikaris |
collection | DOAJ |
description | In the attempt to manage presbyopia, different intraocular lens designs have been proposed such as monofocal IOLs with monovision or multifocal IOLs. Even though the lenses mentioned offer satisfactory visual results, contemporary ophthalmology has not completely answered the presbyopic dilemma by simulating the accommodative properties of the crystalline lens itself. Accommodative IOLs were designed to fill this gap and provide satisfactory vision for all distances by restoring some degree of “pseudoaccommodation.” Pseudo accommodative capability can be linked to monofocal IOL’s as well but the results are not satisfactory enough to fully support unaided near vision. Pseudoaccommodation is a complex phenomenon that can be attributed to several static (i.e., pupil size, against-the-rule cylindrical refractive error, multifocality of the cornea) and dynamic (i.e., anterior movement of the implant itself) factors. Objective measurement of the accommodative capability offered by the accommodative IOLs is extremely difficult to obtain, and different methods such as autorefractometers, retinoscopy, and ultrasound imaging during accommodative effort, ray tracing, or pharmacological stimulation have been developed but the results are sometimes inconsistent. Despite the difficulties in measuring accommodation, accommodative IOLs represent the future in the attempt to successfully “cure” presbyopia. |
format | Article |
id | doaj-art-61373d8c53c3456285fdba09152c898d |
institution | Kabale University |
issn | 2090-004X 2090-0058 |
language | English |
publishDate | 2011-01-01 |
publisher | Wiley |
record_format | Article |
series | Journal of Ophthalmology |
spelling | doaj-art-61373d8c53c3456285fdba09152c898d2025-02-03T01:01:13ZengWileyJournal of Ophthalmology2090-004X2090-00582011-01-01201110.1155/2011/284961284961Real and Pseudoaccommodation in Accommodative LensesIoannis G. Pallikaris0Georgios A. Kontadakis1Dimitra M. Portaliou2Institute of Vision and Optics (IVO), University of Crete, Medical School, Heraklion, 71003 Crete, GreeceInstitute of Vision and Optics (IVO), University of Crete, Medical School, Heraklion, 71003 Crete, GreeceInstitute of Vision and Optics (IVO), University of Crete, Medical School, Heraklion, 71003 Crete, GreeceIn the attempt to manage presbyopia, different intraocular lens designs have been proposed such as monofocal IOLs with monovision or multifocal IOLs. Even though the lenses mentioned offer satisfactory visual results, contemporary ophthalmology has not completely answered the presbyopic dilemma by simulating the accommodative properties of the crystalline lens itself. Accommodative IOLs were designed to fill this gap and provide satisfactory vision for all distances by restoring some degree of “pseudoaccommodation.” Pseudo accommodative capability can be linked to monofocal IOL’s as well but the results are not satisfactory enough to fully support unaided near vision. Pseudoaccommodation is a complex phenomenon that can be attributed to several static (i.e., pupil size, against-the-rule cylindrical refractive error, multifocality of the cornea) and dynamic (i.e., anterior movement of the implant itself) factors. Objective measurement of the accommodative capability offered by the accommodative IOLs is extremely difficult to obtain, and different methods such as autorefractometers, retinoscopy, and ultrasound imaging during accommodative effort, ray tracing, or pharmacological stimulation have been developed but the results are sometimes inconsistent. Despite the difficulties in measuring accommodation, accommodative IOLs represent the future in the attempt to successfully “cure” presbyopia.http://dx.doi.org/10.1155/2011/284961 |
spellingShingle | Ioannis G. Pallikaris Georgios A. Kontadakis Dimitra M. Portaliou Real and Pseudoaccommodation in Accommodative Lenses Journal of Ophthalmology |
title | Real and Pseudoaccommodation in Accommodative Lenses |
title_full | Real and Pseudoaccommodation in Accommodative Lenses |
title_fullStr | Real and Pseudoaccommodation in Accommodative Lenses |
title_full_unstemmed | Real and Pseudoaccommodation in Accommodative Lenses |
title_short | Real and Pseudoaccommodation in Accommodative Lenses |
title_sort | real and pseudoaccommodation in accommodative lenses |
url | http://dx.doi.org/10.1155/2011/284961 |
work_keys_str_mv | AT ioannisgpallikaris realandpseudoaccommodationinaccommodativelenses AT georgiosakontadakis realandpseudoaccommodationinaccommodativelenses AT dimitramportaliou realandpseudoaccommodationinaccommodativelenses |