Visual Outcomes and Quality of Vision After Bilateral Implantation of a Hydrophobic Acrylic Trifocal Intraocular Lens

T Hunter Newsom,1 Brian Szabo,1 Kayla Unsell,1 Chase Newsom,1 Brooke Ayers Newsom,1 Brad Hall2 1Newsom Eye, Sebring, FL, USA; 2Sengi, Penniac, NB, CanadaCorrespondence: T Hunter Newsom, Newsom Eye, 4211 US Hwy 27 N, Sebring, FL, 33870, USA, Tel +1-813-908-2020, Email hunter@newsomeye.netPurpose: To...

Full description

Saved in:
Bibliographic Details
Main Authors: Newsom TH, Szabo B, Unsell K, Newsom C, Newsom BA, Hall B
Format: Article
Language:English
Published: Dove Medical Press 2025-01-01
Series:Clinical Ophthalmology
Subjects:
Online Access:https://www.dovepress.com/visual-outcomes-and-quality-of-vision-after-bilateral-implantation-of--peer-reviewed-fulltext-article-OPTH
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1832592067085205504
author Newsom TH
Szabo B
Unsell K
Newsom C
Newsom BA
Hall B
author_facet Newsom TH
Szabo B
Unsell K
Newsom C
Newsom BA
Hall B
author_sort Newsom TH
collection DOAJ
description T Hunter Newsom,1 Brian Szabo,1 Kayla Unsell,1 Chase Newsom,1 Brooke Ayers Newsom,1 Brad Hall2 1Newsom Eye, Sebring, FL, USA; 2Sengi, Penniac, NB, CanadaCorrespondence: T Hunter Newsom, Newsom Eye, 4211 US Hwy 27 N, Sebring, FL, 33870, USA, Tel +1-813-908-2020, Email hunter@newsomeye.netPurpose: To evaluate visual outcomes and quality of vision following bilateral implantation of a hydrophobic acrylic intraocular lens (IOL) in eyes targeted for emmetropia.Methods: This was a prospective, single arm study. Subjects were bilaterally implanted with the Clareon PanOptix IOL and evaluated at 1 and 3 months postoperatively. Endpoints included binocular uncorrected and distance-corrected visual acuities at distance (UDVA, CDVA), intermediate (UIVA, DCIVA; 60 cm), and near (UNVA, DCNVA; 40 cm, 33 cm), defocus curve, manifest refraction, and administration of a visual disturbance questionnaire (QUVID) and a satisfaction questionnaire (IOLSAT).Results: A total of 24 subjects (48 eyes) completed the study. Mean postoperative binocular CDVA, DCIVA (60 cm), DCNVA (40 cm), and DCNVA (33 cm) were − 0.04 ± 0.08 logMAR, − 0.08 ± 0.10 logMAR, 0.01 ± 0.10 logMAR, and 0.04 ± 0.11 logMAR, respectively. Mean postoperative binocular UDVA, UIVA (60 cm), UNVA (40 cm), and UNVA (33 cm) were 0.02 ± 0.19 logMAR, − 0.08 ± 0.09 logMAR, 0.04 ± 0.12 logMAR, and 0.08 ± 0.15 logMAR, respectively. Overall, postoperative spectacle independence at distance, intermediate, and near were 100%, 93%, and 73%, respectively. A total of 9%, 12%, and 0% of subjects were bothered “quite a bit” or “very much” by halos, starburst, and glare, respectively.Conclusion: The results of this study suggest that bilateral implantation with the Clareon PanOptix can achieve excellent visual outcomes, high spectacle independence, and low reports of bothersome dysphotopsia.Plain Language Summary: The natural lens inside the eye may eventually become opaque (develop a cataract). When that happens, it can be removed and replaced with an artificial intraocular lens (IOL). There are a variety of IOLs to choose from. For patients desiring spectacle independence, trifocal IOLs may be good option as this type of IOL is designed to provide clear vision to see far, arm’s length, and up close objects. The purpose of this study was to evaluate the visual outcomes and quality of vision following bilateral implantation of a new hydrophobic acrylic IOL (Clareon PanOptix). The results of this study suggest that bilateral implantation with the Clareon PanOptix can achieve excellent visual outcomes, high spectacle independence, and low reports of bothersome dysphotopsia.Keywords: PanOptix, Clareon, cataract surgery
format Article
id doaj-art-5d2d68d4760f497b90053dbf1b3b2e2b
institution Kabale University
issn 1177-5483
language English
publishDate 2025-01-01
publisher Dove Medical Press
record_format Article
series Clinical Ophthalmology
spelling doaj-art-5d2d68d4760f497b90053dbf1b3b2e2b2025-01-21T16:58:07ZengDove Medical PressClinical Ophthalmology1177-54832025-01-01Volume 1922723499441Visual Outcomes and Quality of Vision After Bilateral Implantation of a Hydrophobic Acrylic Trifocal Intraocular LensNewsom THSzabo BUnsell KNewsom CNewsom BAHall BT Hunter Newsom,1 Brian Szabo,1 Kayla Unsell,1 Chase Newsom,1 Brooke Ayers Newsom,1 Brad Hall2 1Newsom Eye, Sebring, FL, USA; 2Sengi, Penniac, NB, CanadaCorrespondence: T Hunter Newsom, Newsom Eye, 4211 US Hwy 27 N, Sebring, FL, 33870, USA, Tel +1-813-908-2020, Email hunter@newsomeye.netPurpose: To evaluate visual outcomes and quality of vision following bilateral implantation of a hydrophobic acrylic intraocular lens (IOL) in eyes targeted for emmetropia.Methods: This was a prospective, single arm study. Subjects were bilaterally implanted with the Clareon PanOptix IOL and evaluated at 1 and 3 months postoperatively. Endpoints included binocular uncorrected and distance-corrected visual acuities at distance (UDVA, CDVA), intermediate (UIVA, DCIVA; 60 cm), and near (UNVA, DCNVA; 40 cm, 33 cm), defocus curve, manifest refraction, and administration of a visual disturbance questionnaire (QUVID) and a satisfaction questionnaire (IOLSAT).Results: A total of 24 subjects (48 eyes) completed the study. Mean postoperative binocular CDVA, DCIVA (60 cm), DCNVA (40 cm), and DCNVA (33 cm) were − 0.04 ± 0.08 logMAR, − 0.08 ± 0.10 logMAR, 0.01 ± 0.10 logMAR, and 0.04 ± 0.11 logMAR, respectively. Mean postoperative binocular UDVA, UIVA (60 cm), UNVA (40 cm), and UNVA (33 cm) were 0.02 ± 0.19 logMAR, − 0.08 ± 0.09 logMAR, 0.04 ± 0.12 logMAR, and 0.08 ± 0.15 logMAR, respectively. Overall, postoperative spectacle independence at distance, intermediate, and near were 100%, 93%, and 73%, respectively. A total of 9%, 12%, and 0% of subjects were bothered “quite a bit” or “very much” by halos, starburst, and glare, respectively.Conclusion: The results of this study suggest that bilateral implantation with the Clareon PanOptix can achieve excellent visual outcomes, high spectacle independence, and low reports of bothersome dysphotopsia.Plain Language Summary: The natural lens inside the eye may eventually become opaque (develop a cataract). When that happens, it can be removed and replaced with an artificial intraocular lens (IOL). There are a variety of IOLs to choose from. For patients desiring spectacle independence, trifocal IOLs may be good option as this type of IOL is designed to provide clear vision to see far, arm’s length, and up close objects. The purpose of this study was to evaluate the visual outcomes and quality of vision following bilateral implantation of a new hydrophobic acrylic IOL (Clareon PanOptix). The results of this study suggest that bilateral implantation with the Clareon PanOptix can achieve excellent visual outcomes, high spectacle independence, and low reports of bothersome dysphotopsia.Keywords: PanOptix, Clareon, cataract surgeryhttps://www.dovepress.com/visual-outcomes-and-quality-of-vision-after-bilateral-implantation-of--peer-reviewed-fulltext-article-OPTHpanoptixclareoncataract surgery
spellingShingle Newsom TH
Szabo B
Unsell K
Newsom C
Newsom BA
Hall B
Visual Outcomes and Quality of Vision After Bilateral Implantation of a Hydrophobic Acrylic Trifocal Intraocular Lens
Clinical Ophthalmology
panoptix
clareon
cataract surgery
title Visual Outcomes and Quality of Vision After Bilateral Implantation of a Hydrophobic Acrylic Trifocal Intraocular Lens
title_full Visual Outcomes and Quality of Vision After Bilateral Implantation of a Hydrophobic Acrylic Trifocal Intraocular Lens
title_fullStr Visual Outcomes and Quality of Vision After Bilateral Implantation of a Hydrophobic Acrylic Trifocal Intraocular Lens
title_full_unstemmed Visual Outcomes and Quality of Vision After Bilateral Implantation of a Hydrophobic Acrylic Trifocal Intraocular Lens
title_short Visual Outcomes and Quality of Vision After Bilateral Implantation of a Hydrophobic Acrylic Trifocal Intraocular Lens
title_sort visual outcomes and quality of vision after bilateral implantation of a hydrophobic acrylic trifocal intraocular lens
topic panoptix
clareon
cataract surgery
url https://www.dovepress.com/visual-outcomes-and-quality-of-vision-after-bilateral-implantation-of--peer-reviewed-fulltext-article-OPTH
work_keys_str_mv AT newsomth visualoutcomesandqualityofvisionafterbilateralimplantationofahydrophobicacrylictrifocalintraocularlens
AT szabob visualoutcomesandqualityofvisionafterbilateralimplantationofahydrophobicacrylictrifocalintraocularlens
AT unsellk visualoutcomesandqualityofvisionafterbilateralimplantationofahydrophobicacrylictrifocalintraocularlens
AT newsomc visualoutcomesandqualityofvisionafterbilateralimplantationofahydrophobicacrylictrifocalintraocularlens
AT newsomba visualoutcomesandqualityofvisionafterbilateralimplantationofahydrophobicacrylictrifocalintraocularlens
AT hallb visualoutcomesandqualityofvisionafterbilateralimplantationofahydrophobicacrylictrifocalintraocularlens