INVARIAN AUTOMATIC CONTROL SYSTEM, USING THE INTERMEDIATE-FREQUENCY SIGNALS OF HEAT POWER PARAMETERS

The usage of digital micro-processing automatic means allow to use design methods (technique) of automatic control systems  more wider, and also to apply optimal ways of control, for example, it is possible to combine the Method of structural-parameter optimization and invariance theory. This method...

Full description

Saved in:
Bibliographic Details
Main Authors: G. T. Kulakov, A. N. Kukhorenko, I. M. Golinko
Format: Article
Language:Russian
Published: Belarusian National Technical University 2015-03-01
Series:Известия высших учебных заведений и энергетических объединенний СНГ: Энергетика
Subjects:
Online Access:https://energy.bntu.by/jour/article/view/848
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1832543706853408768
author G. T. Kulakov
A. N. Kukhorenko
I. M. Golinko
author_facet G. T. Kulakov
A. N. Kukhorenko
I. M. Golinko
author_sort G. T. Kulakov
collection DOAJ
description The usage of digital micro-processing automatic means allow to use design methods (technique) of automatic control systems  more wider, and also to apply optimal ways of control, for example, it is possible to combine the Method of structural-parameter optimization and invariance theory. This method allow to increase essential system speed in processing of task jump and to reduce operation time of outside external disturbance up to two  values of regulated influence, and the usage of invariance principle is based on an additional measuring of the most dangerous perturbation influence and in connection with it the improvement of regulation quality is achieved.In this article the principle of invariance is applied in order to improve greatly external disturbance attack by consumption of over-heated steam. Compensation of disturbance influence on regulated value is achieving by introduction of additional signal on input of correction regulator from output of compensation device, measuring the external disturbance by consumption of over-heated steam.Modeling results of transient processes of cascade system of automatic control (CSAC), on the base of which were realized the unity of these methods, demonstrated the fact that, in processing of external disturbance by consumption of steam, the reduction of maximal dynamic regulation error is six times and cutting of regulation time by 30 % in comparison with CSAC without compensation device of external disturbance. And that is why it leads to the further reduction of maximal dynamic regulation error in processing of external disturbance by consumption of steam, and this allows to improve the quality of control.
format Article
id doaj-art-5c7cf8eeb70248d7870e6ceef601da7d
institution Kabale University
issn 1029-7448
2414-0341
language Russian
publishDate 2015-03-01
publisher Belarusian National Technical University
record_format Article
series Известия высших учебных заведений и энергетических объединенний СНГ: Энергетика
spelling doaj-art-5c7cf8eeb70248d7870e6ceef601da7d2025-02-03T11:34:19ZrusBelarusian National Technical UniversityИзвестия высших учебных заведений и энергетических объединенний СНГ: Энергетика1029-74482414-03412015-03-01016272830INVARIAN AUTOMATIC CONTROL SYSTEM, USING THE INTERMEDIATE-FREQUENCY SIGNALS OF HEAT POWER PARAMETERSG. T. Kulakov0A. N. Kukhorenko1I. M. Golinko2Belarusian National Technical UniversityCommand-engineering institute of MES of the Republic of BelarusNational Technical University of Ukraine “Kiev Polytechnic Institute”The usage of digital micro-processing automatic means allow to use design methods (technique) of automatic control systems  more wider, and also to apply optimal ways of control, for example, it is possible to combine the Method of structural-parameter optimization and invariance theory. This method allow to increase essential system speed in processing of task jump and to reduce operation time of outside external disturbance up to two  values of regulated influence, and the usage of invariance principle is based on an additional measuring of the most dangerous perturbation influence and in connection with it the improvement of regulation quality is achieved.In this article the principle of invariance is applied in order to improve greatly external disturbance attack by consumption of over-heated steam. Compensation of disturbance influence on regulated value is achieving by introduction of additional signal on input of correction regulator from output of compensation device, measuring the external disturbance by consumption of over-heated steam.Modeling results of transient processes of cascade system of automatic control (CSAC), on the base of which were realized the unity of these methods, demonstrated the fact that, in processing of external disturbance by consumption of steam, the reduction of maximal dynamic regulation error is six times and cutting of regulation time by 30 % in comparison with CSAC without compensation device of external disturbance. And that is why it leads to the further reduction of maximal dynamic regulation error in processing of external disturbance by consumption of steam, and this allows to improve the quality of control.https://energy.bntu.by/jour/article/view/848controlmethod of structural-parameter optimizationtheory of invariance
spellingShingle G. T. Kulakov
A. N. Kukhorenko
I. M. Golinko
INVARIAN AUTOMATIC CONTROL SYSTEM, USING THE INTERMEDIATE-FREQUENCY SIGNALS OF HEAT POWER PARAMETERS
Известия высших учебных заведений и энергетических объединенний СНГ: Энергетика
control
method of structural-parameter optimization
theory of invariance
title INVARIAN AUTOMATIC CONTROL SYSTEM, USING THE INTERMEDIATE-FREQUENCY SIGNALS OF HEAT POWER PARAMETERS
title_full INVARIAN AUTOMATIC CONTROL SYSTEM, USING THE INTERMEDIATE-FREQUENCY SIGNALS OF HEAT POWER PARAMETERS
title_fullStr INVARIAN AUTOMATIC CONTROL SYSTEM, USING THE INTERMEDIATE-FREQUENCY SIGNALS OF HEAT POWER PARAMETERS
title_full_unstemmed INVARIAN AUTOMATIC CONTROL SYSTEM, USING THE INTERMEDIATE-FREQUENCY SIGNALS OF HEAT POWER PARAMETERS
title_short INVARIAN AUTOMATIC CONTROL SYSTEM, USING THE INTERMEDIATE-FREQUENCY SIGNALS OF HEAT POWER PARAMETERS
title_sort invarian automatic control system using the intermediate frequency signals of heat power parameters
topic control
method of structural-parameter optimization
theory of invariance
url https://energy.bntu.by/jour/article/view/848
work_keys_str_mv AT gtkulakov invarianautomaticcontrolsystemusingtheintermediatefrequencysignalsofheatpowerparameters
AT ankukhorenko invarianautomaticcontrolsystemusingtheintermediatefrequencysignalsofheatpowerparameters
AT imgolinko invarianautomaticcontrolsystemusingtheintermediatefrequencysignalsofheatpowerparameters