Design of Coupling Coil Parameters for Wireless Charging Tram Based on Electromagnetic Safety
As a new type of urban rail transit tram, wireless charging tram uses high frequency electromagnetic field to conduct inductive power transmission, which gets rid of the traditional overhead catenary network, but inevitably causes electromagnetic radiation to the surrounding environment. Research sh...
Saved in:
Main Authors: | , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Wiley
2022-01-01
|
Series: | Journal of Advanced Transportation |
Online Access: | http://dx.doi.org/10.1155/2022/5769224 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
_version_ | 1832565779485163520 |
---|---|
author | Sanmu Xiu Wenmei Hao Ying Zhou Fengyu Leng |
author_facet | Sanmu Xiu Wenmei Hao Ying Zhou Fengyu Leng |
author_sort | Sanmu Xiu |
collection | DOAJ |
description | As a new type of urban rail transit tram, wireless charging tram uses high frequency electromagnetic field to conduct inductive power transmission, which gets rid of the traditional overhead catenary network, but inevitably causes electromagnetic radiation to the surrounding environment. Research shows that excessive electromagnetic radiation will affect the normal operation of equipment and the safety of human body. This paper analyzes the structure and coil configuration of the dynamic charging system for wireless charging tram. Aiming at the problem of electromagnetic radiation, a mathematical model with minimum electromagnetic radiation as the target and system parameters as the constraint condition is established. Finally, the system parameters of the electromagnetic coupling mechanism of the wireless charging tram are designed and optimized. The simulation and experimental results show that the method can meet the operating requirements of the system and reduce the electromagnetic radiation to the surrounding environment. |
format | Article |
id | doaj-art-5ad8fffa4bb64f429b56389accc3db2e |
institution | Kabale University |
issn | 2042-3195 |
language | English |
publishDate | 2022-01-01 |
publisher | Wiley |
record_format | Article |
series | Journal of Advanced Transportation |
spelling | doaj-art-5ad8fffa4bb64f429b56389accc3db2e2025-02-03T01:06:42ZengWileyJournal of Advanced Transportation2042-31952022-01-01202210.1155/2022/5769224Design of Coupling Coil Parameters for Wireless Charging Tram Based on Electromagnetic SafetySanmu Xiu0Wenmei Hao1Ying Zhou2Fengyu Leng3School of Electrical EngineeringSchool of Mechanical EngineeringCRRCInstitute of Electrical EngineeringAs a new type of urban rail transit tram, wireless charging tram uses high frequency electromagnetic field to conduct inductive power transmission, which gets rid of the traditional overhead catenary network, but inevitably causes electromagnetic radiation to the surrounding environment. Research shows that excessive electromagnetic radiation will affect the normal operation of equipment and the safety of human body. This paper analyzes the structure and coil configuration of the dynamic charging system for wireless charging tram. Aiming at the problem of electromagnetic radiation, a mathematical model with minimum electromagnetic radiation as the target and system parameters as the constraint condition is established. Finally, the system parameters of the electromagnetic coupling mechanism of the wireless charging tram are designed and optimized. The simulation and experimental results show that the method can meet the operating requirements of the system and reduce the electromagnetic radiation to the surrounding environment.http://dx.doi.org/10.1155/2022/5769224 |
spellingShingle | Sanmu Xiu Wenmei Hao Ying Zhou Fengyu Leng Design of Coupling Coil Parameters for Wireless Charging Tram Based on Electromagnetic Safety Journal of Advanced Transportation |
title | Design of Coupling Coil Parameters for Wireless Charging Tram Based on Electromagnetic Safety |
title_full | Design of Coupling Coil Parameters for Wireless Charging Tram Based on Electromagnetic Safety |
title_fullStr | Design of Coupling Coil Parameters for Wireless Charging Tram Based on Electromagnetic Safety |
title_full_unstemmed | Design of Coupling Coil Parameters for Wireless Charging Tram Based on Electromagnetic Safety |
title_short | Design of Coupling Coil Parameters for Wireless Charging Tram Based on Electromagnetic Safety |
title_sort | design of coupling coil parameters for wireless charging tram based on electromagnetic safety |
url | http://dx.doi.org/10.1155/2022/5769224 |
work_keys_str_mv | AT sanmuxiu designofcouplingcoilparametersforwirelesschargingtrambasedonelectromagneticsafety AT wenmeihao designofcouplingcoilparametersforwirelesschargingtrambasedonelectromagneticsafety AT yingzhou designofcouplingcoilparametersforwirelesschargingtrambasedonelectromagneticsafety AT fengyuleng designofcouplingcoilparametersforwirelesschargingtrambasedonelectromagneticsafety |