Galloping Stability and Wind Tunnel Test of Iced Quad Bundled Conductors considering Wake Effect
A new quad bundle conductor galloping model considering wake effect is proposed to solve the problem of different aerodynamic coefficients of each subconductor of iced quad bundle conductor. Based on the quasistatic theory, a new 3-DOF (three degrees of freedom) galloping model of iced quad bundle c...
Saved in:
Main Authors: | , , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Wiley
2020-01-01
|
Series: | Discrete Dynamics in Nature and Society |
Online Access: | http://dx.doi.org/10.1155/2020/8885648 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
_version_ | 1832550905130516480 |
---|---|
author | Xiaohui Liu Ming Zou Chuan Wu Mengqi Cai Guangyun Min Shuguang Yang |
author_facet | Xiaohui Liu Ming Zou Chuan Wu Mengqi Cai Guangyun Min Shuguang Yang |
author_sort | Xiaohui Liu |
collection | DOAJ |
description | A new quad bundle conductor galloping model considering wake effect is proposed to solve the problem of different aerodynamic coefficients of each subconductor of iced quad bundle conductor. Based on the quasistatic theory, a new 3-DOF (three degrees of freedom) galloping model of iced quad bundle conductors is established, which can accurately reflect the energy transfer and galloping of quad bundle conductor in three directions. After a series of formula derivations, the conductor stability judgment formula is obtained. In the wind tunnel test, according to the actual engineering situation, different variables are set up to accurately simulate the galloping of iced quad bundle conductor under the wind, and the aerodynamic coefficient is obtained. Finally, according to the stability judgment formula of this paper, calculate the critical wind speed of conductor galloping through programming. The dates of wind tunnel test and calculation in this paper can be used in the antigalloping design of transmission lines. |
format | Article |
id | doaj-art-5ac5d90335fd4d30b596a862208da463 |
institution | Kabale University |
issn | 1026-0226 1607-887X |
language | English |
publishDate | 2020-01-01 |
publisher | Wiley |
record_format | Article |
series | Discrete Dynamics in Nature and Society |
spelling | doaj-art-5ac5d90335fd4d30b596a862208da4632025-02-03T06:05:28ZengWileyDiscrete Dynamics in Nature and Society1026-02261607-887X2020-01-01202010.1155/2020/88856488885648Galloping Stability and Wind Tunnel Test of Iced Quad Bundled Conductors considering Wake EffectXiaohui Liu0Ming Zou1Chuan Wu2Mengqi Cai3Guangyun Min4Shuguang Yang5State Key Laboratory of Mountain Bridge and Tunnel Engineering, Chongqing Jiaotong University, Chongqing 400074, ChinaCollege of Civil Engineering, Chongqing Jiaotong University, Chongqing 400074, ChinaState Grid Henan Electric Power Research Institute, Zhengzhou 450052, ChinaCollege of Architecture and Civil Engineering, Chengdu University, Chengdu 610106, ChinaCollege of Civil Engineering, Chongqing Jiaotong University, Chongqing 400074, ChinaCollege of Civil Engineering, Chongqing Jiaotong University, Chongqing 400074, ChinaA new quad bundle conductor galloping model considering wake effect is proposed to solve the problem of different aerodynamic coefficients of each subconductor of iced quad bundle conductor. Based on the quasistatic theory, a new 3-DOF (three degrees of freedom) galloping model of iced quad bundle conductors is established, which can accurately reflect the energy transfer and galloping of quad bundle conductor in three directions. After a series of formula derivations, the conductor stability judgment formula is obtained. In the wind tunnel test, according to the actual engineering situation, different variables are set up to accurately simulate the galloping of iced quad bundle conductor under the wind, and the aerodynamic coefficient is obtained. Finally, according to the stability judgment formula of this paper, calculate the critical wind speed of conductor galloping through programming. The dates of wind tunnel test and calculation in this paper can be used in the antigalloping design of transmission lines.http://dx.doi.org/10.1155/2020/8885648 |
spellingShingle | Xiaohui Liu Ming Zou Chuan Wu Mengqi Cai Guangyun Min Shuguang Yang Galloping Stability and Wind Tunnel Test of Iced Quad Bundled Conductors considering Wake Effect Discrete Dynamics in Nature and Society |
title | Galloping Stability and Wind Tunnel Test of Iced Quad Bundled Conductors considering Wake Effect |
title_full | Galloping Stability and Wind Tunnel Test of Iced Quad Bundled Conductors considering Wake Effect |
title_fullStr | Galloping Stability and Wind Tunnel Test of Iced Quad Bundled Conductors considering Wake Effect |
title_full_unstemmed | Galloping Stability and Wind Tunnel Test of Iced Quad Bundled Conductors considering Wake Effect |
title_short | Galloping Stability and Wind Tunnel Test of Iced Quad Bundled Conductors considering Wake Effect |
title_sort | galloping stability and wind tunnel test of iced quad bundled conductors considering wake effect |
url | http://dx.doi.org/10.1155/2020/8885648 |
work_keys_str_mv | AT xiaohuiliu gallopingstabilityandwindtunneltestoficedquadbundledconductorsconsideringwakeeffect AT mingzou gallopingstabilityandwindtunneltestoficedquadbundledconductorsconsideringwakeeffect AT chuanwu gallopingstabilityandwindtunneltestoficedquadbundledconductorsconsideringwakeeffect AT mengqicai gallopingstabilityandwindtunneltestoficedquadbundledconductorsconsideringwakeeffect AT guangyunmin gallopingstabilityandwindtunneltestoficedquadbundledconductorsconsideringwakeeffect AT shuguangyang gallopingstabilityandwindtunneltestoficedquadbundledconductorsconsideringwakeeffect |