Initial Clinical Trial of Robot of Endovascular Treatment with Force Feedback and Cooperating of Catheter and Guidewire

To evaluate the feasibility and safety of the robot of endovascular treatment (RobEnt) in clinical practice, we carried out a cerebral angiography using this robot system. We evaluated the performance of application of the robot system to clinical practice through using this robotic system to perfor...

Full description

Saved in:
Bibliographic Details
Main Authors: Yuhua Jiang, Keyun Liu, Youxiang Li
Format: Article
Language:English
Published: Wiley 2018-01-01
Series:Applied Bionics and Biomechanics
Online Access:http://dx.doi.org/10.1155/2018/9735979
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1832547637588393984
author Yuhua Jiang
Keyun Liu
Youxiang Li
author_facet Yuhua Jiang
Keyun Liu
Youxiang Li
author_sort Yuhua Jiang
collection DOAJ
description To evaluate the feasibility and safety of the robot of endovascular treatment (RobEnt) in clinical practice, we carried out a cerebral angiography using this robot system. We evaluated the performance of application of the robot system to clinical practice through using this robotic system to perform the digital subtraction angiography for a patient who was suspected of suffering intracranial aneurysm. At the same time, through comparing the postoperative head nuclear magnetic and blood routine with the preoperative examination, we evaluated the safety of application of the robot system to clinical practice. We performed the robot system to complete the bilateral carotid artery and bilateral vertebral arteriography. The results indicate that there was no obvious abnormality in the patient’s cerebral artery. No obvious abnormality was observed in the examination of patients’ check-up, head nuclear magnetism, and blood routine after the digital subtraction angiography. From this clinical trial, it can be observed that the robot system can perform the operation of cerebral angiography. The robot system can basically complete the related observation indexes, and its accuracy, effectiveness, stability, and safety basically meet the requirements of clinical application in neurointerventional surgery.
format Article
id doaj-art-5a859558778b44bd95e53daf99cc6597
institution Kabale University
issn 1176-2322
1754-2103
language English
publishDate 2018-01-01
publisher Wiley
record_format Article
series Applied Bionics and Biomechanics
spelling doaj-art-5a859558778b44bd95e53daf99cc65972025-02-03T06:44:00ZengWileyApplied Bionics and Biomechanics1176-23221754-21032018-01-01201810.1155/2018/97359799735979Initial Clinical Trial of Robot of Endovascular Treatment with Force Feedback and Cooperating of Catheter and GuidewireYuhua Jiang0Keyun Liu1Youxiang Li2Department of Interventional Neuroradiology, Beijing Neurosurgical Institute and Beijing Tiantan Hospital, Capital Medical University, Beijing 100050, ChinaDepartment of Interventional Neuroradiology, Beijing Neurosurgical Institute and Beijing Tiantan Hospital, Capital Medical University, Beijing 100050, ChinaDepartment of Interventional Neuroradiology, Beijing Neurosurgical Institute and Beijing Tiantan Hospital, Capital Medical University, Beijing 100050, ChinaTo evaluate the feasibility and safety of the robot of endovascular treatment (RobEnt) in clinical practice, we carried out a cerebral angiography using this robot system. We evaluated the performance of application of the robot system to clinical practice through using this robotic system to perform the digital subtraction angiography for a patient who was suspected of suffering intracranial aneurysm. At the same time, through comparing the postoperative head nuclear magnetic and blood routine with the preoperative examination, we evaluated the safety of application of the robot system to clinical practice. We performed the robot system to complete the bilateral carotid artery and bilateral vertebral arteriography. The results indicate that there was no obvious abnormality in the patient’s cerebral artery. No obvious abnormality was observed in the examination of patients’ check-up, head nuclear magnetism, and blood routine after the digital subtraction angiography. From this clinical trial, it can be observed that the robot system can perform the operation of cerebral angiography. The robot system can basically complete the related observation indexes, and its accuracy, effectiveness, stability, and safety basically meet the requirements of clinical application in neurointerventional surgery.http://dx.doi.org/10.1155/2018/9735979
spellingShingle Yuhua Jiang
Keyun Liu
Youxiang Li
Initial Clinical Trial of Robot of Endovascular Treatment with Force Feedback and Cooperating of Catheter and Guidewire
Applied Bionics and Biomechanics
title Initial Clinical Trial of Robot of Endovascular Treatment with Force Feedback and Cooperating of Catheter and Guidewire
title_full Initial Clinical Trial of Robot of Endovascular Treatment with Force Feedback and Cooperating of Catheter and Guidewire
title_fullStr Initial Clinical Trial of Robot of Endovascular Treatment with Force Feedback and Cooperating of Catheter and Guidewire
title_full_unstemmed Initial Clinical Trial of Robot of Endovascular Treatment with Force Feedback and Cooperating of Catheter and Guidewire
title_short Initial Clinical Trial of Robot of Endovascular Treatment with Force Feedback and Cooperating of Catheter and Guidewire
title_sort initial clinical trial of robot of endovascular treatment with force feedback and cooperating of catheter and guidewire
url http://dx.doi.org/10.1155/2018/9735979
work_keys_str_mv AT yuhuajiang initialclinicaltrialofrobotofendovasculartreatmentwithforcefeedbackandcooperatingofcatheterandguidewire
AT keyunliu initialclinicaltrialofrobotofendovasculartreatmentwithforcefeedbackandcooperatingofcatheterandguidewire
AT youxiangli initialclinicaltrialofrobotofendovasculartreatmentwithforcefeedbackandcooperatingofcatheterandguidewire