Introduction of an Auxiliary Breaker into the Generator-Transformer Block for Energy Saving in Open Switchgear Circuits of Power Plants

A need in finding of new ways of energy saving at open switchgears of power plants is substantiated. In order to increase energy saving efficiency, an auxiliary breaker is suggested to be inserted between a transformer of a block and its two high-voltage circuit breakers. The reasonability of such a...

Full description

Saved in:
Bibliographic Details
Main Authors: A. S. Barukin, M. Ya. Kletsel, A. Zh. Dinmukhanbetova, D. A. Amirbek
Format: Article
Language:Russian
Published: Belarusian National Technical University 2023-08-01
Series:Известия высших учебных заведений и энергетических объединенний СНГ: Энергетика
Subjects:
Online Access:https://energy.bntu.by/jour/article/view/2289
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:A need in finding of new ways of energy saving at open switchgears of power plants is substantiated. In order to increase energy saving efficiency, an auxiliary breaker is suggested to be inserted between a transformer of a block and its two high-voltage circuit breakers. The reasonability of such an insertion is proved on the basis of comparing of calculations resultsof under-discharge of electricity (UE) by the tabular-logical method (Yu. B. Guk) of the obtained schemes and of the traditional ones. For the calculations, the conditions that arose due to the change in the main circuit of a power plant are studied. Also, equations are given for calculation of a decrease in UE, damage due to it during reconstruction, and costs for the construction of a power plant (the costs are assumed to be the same in all options). Russian statistical data and the predicted failure rate λEV of a 750 kV SF6 circuit breaker are used. An option of the introduction of an SF6 circuit breaker with and without replacement of other circuit breakers with SF6 circuit breakers is considered. The results of calculations of UE, damage, and costs for the introduction suggested are tabulated, where changes in them due to the introduction of the circuit breaker are estimated for 18 ring circuits and 17 “3/2” and “4/3” circuits of 330–750 kV switchgears at condensation, nuclear, and hydroelectric power plants. It is demonstrated that the presence of a generator breaker in the blocks makes it possible to reduce these energy-saving efficiency indicators several times. A technique for determining the failure rate of a hypothetical circuit breaker, which, in the case of traditional replacement, is capable of producing the same effect as an SF6 circuit breaker inserted is proposed. An example of determining this frequency is given. Results of the calculated reduction of UE, damage and costs for the case of an air circuit breaker having been substituted to an SF6 circuit breaker are presented.
ISSN:1029-7448
2414-0341