Finite Element Analysis of the Effect of Tightening Torque on the Connection Stability of a Two-Piece Zirconia Implant System

Purpose. Loosening and fracture of abutment screws are one of the most common complications in implant-retained fixed prostheses. Thus, applying the proper tightening torque to the abutment screw is important for preventing the loosening effect of the abutment screw and ensuring the stability of the...

Full description

Saved in:
Bibliographic Details
Main Authors: Hyunsuk Choi, Min-Ho Hong
Format: Article
Language:English
Published: Wiley 2022-01-01
Series:Advances in Materials Science and Engineering
Online Access:http://dx.doi.org/10.1155/2022/1456475
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1832549029420990464
author Hyunsuk Choi
Min-Ho Hong
author_facet Hyunsuk Choi
Min-Ho Hong
author_sort Hyunsuk Choi
collection DOAJ
description Purpose. Loosening and fracture of abutment screws are one of the most common complications in implant-retained fixed prostheses. Thus, applying the proper tightening torque to the abutment screw is important for preventing the loosening effect of the abutment screw and ensuring the stability of the implant fixture-abutment connection. Therefore, in this study, we aimed to investigate the effect of the tightening torque of the abutment screw on the stability of the fixture-abutment connection in a two-piece zirconia implant system using finite element analysis (FEA). Materials and Methods. The two-piece zirconia implant structures used in this study were designed using the CATIA program. The abutment screws with tightening torques of 25 (TT-25), 35 (TT-35), and 45 (TT-45) N·cm were assumed to fix the abutment and fixture. Vertical (200 N) and oblique (100 N) loads were applied to the finite element model generated for FEA simulation, and the stress levels and distributions were investigated. Results. The TT-45 group exhibited the highest von Mises stress in the abutment and fixture, followed by the TT-35 and TT-25 groups. The von Mises and minimal principal stresses of the abutment screw were also highest in the TT-45 group, followed by the TT-35 and TT-25 groups. In all three groups, the area with the highest stress concentration was located at the point of contact with the bottom of the screw head. Furthermore, the TT-25 group showed the highest safety factor value. The TT-35 group showed a safety factor value similar to the safe minimum standard, while the TT-45 group showed a lower safety factor value. Conclusion. When a torque of 35 N cm was applied to the two-piece zirconia implant system, it showed a maximum stress value close to 660 MPa (75% of the yield strength of the Ti-6Al-4V alloy), which is the optimal preload recommended for abutment screws.
format Article
id doaj-art-58164d621bbb4a9b8ba99cd279e5a77a
institution Kabale University
issn 1687-8442
language English
publishDate 2022-01-01
publisher Wiley
record_format Article
series Advances in Materials Science and Engineering
spelling doaj-art-58164d621bbb4a9b8ba99cd279e5a77a2025-02-03T06:12:26ZengWileyAdvances in Materials Science and Engineering1687-84422022-01-01202210.1155/2022/1456475Finite Element Analysis of the Effect of Tightening Torque on the Connection Stability of a Two-Piece Zirconia Implant SystemHyunsuk Choi0Min-Ho Hong1Department of Dentistry and ProsthodonticsDepartment of Dental Laboratory SciencePurpose. Loosening and fracture of abutment screws are one of the most common complications in implant-retained fixed prostheses. Thus, applying the proper tightening torque to the abutment screw is important for preventing the loosening effect of the abutment screw and ensuring the stability of the implant fixture-abutment connection. Therefore, in this study, we aimed to investigate the effect of the tightening torque of the abutment screw on the stability of the fixture-abutment connection in a two-piece zirconia implant system using finite element analysis (FEA). Materials and Methods. The two-piece zirconia implant structures used in this study were designed using the CATIA program. The abutment screws with tightening torques of 25 (TT-25), 35 (TT-35), and 45 (TT-45) N·cm were assumed to fix the abutment and fixture. Vertical (200 N) and oblique (100 N) loads were applied to the finite element model generated for FEA simulation, and the stress levels and distributions were investigated. Results. The TT-45 group exhibited the highest von Mises stress in the abutment and fixture, followed by the TT-35 and TT-25 groups. The von Mises and minimal principal stresses of the abutment screw were also highest in the TT-45 group, followed by the TT-35 and TT-25 groups. In all three groups, the area with the highest stress concentration was located at the point of contact with the bottom of the screw head. Furthermore, the TT-25 group showed the highest safety factor value. The TT-35 group showed a safety factor value similar to the safe minimum standard, while the TT-45 group showed a lower safety factor value. Conclusion. When a torque of 35 N cm was applied to the two-piece zirconia implant system, it showed a maximum stress value close to 660 MPa (75% of the yield strength of the Ti-6Al-4V alloy), which is the optimal preload recommended for abutment screws.http://dx.doi.org/10.1155/2022/1456475
spellingShingle Hyunsuk Choi
Min-Ho Hong
Finite Element Analysis of the Effect of Tightening Torque on the Connection Stability of a Two-Piece Zirconia Implant System
Advances in Materials Science and Engineering
title Finite Element Analysis of the Effect of Tightening Torque on the Connection Stability of a Two-Piece Zirconia Implant System
title_full Finite Element Analysis of the Effect of Tightening Torque on the Connection Stability of a Two-Piece Zirconia Implant System
title_fullStr Finite Element Analysis of the Effect of Tightening Torque on the Connection Stability of a Two-Piece Zirconia Implant System
title_full_unstemmed Finite Element Analysis of the Effect of Tightening Torque on the Connection Stability of a Two-Piece Zirconia Implant System
title_short Finite Element Analysis of the Effect of Tightening Torque on the Connection Stability of a Two-Piece Zirconia Implant System
title_sort finite element analysis of the effect of tightening torque on the connection stability of a two piece zirconia implant system
url http://dx.doi.org/10.1155/2022/1456475
work_keys_str_mv AT hyunsukchoi finiteelementanalysisoftheeffectoftighteningtorqueontheconnectionstabilityofatwopiecezirconiaimplantsystem
AT minhohong finiteelementanalysisoftheeffectoftighteningtorqueontheconnectionstabilityofatwopiecezirconiaimplantsystem