The Correlation between Time in Range and Diabetic Microvascular Complications Utilizing Information Management Platform

Background. In recent years, the time of blood glucose within the target range is a new research hotspot in blood glucose management. TIR is expected to be a novel indicator for evaluating the efficacy of glycemic control and predicting diabetic complications. However, its relationship with diabetic...

Full description

Saved in:
Bibliographic Details
Main Authors: Xia Sheng, Guo-Hui Xiong, Peng-Fei Yu, Jian-Ping Liu
Format: Article
Language:English
Published: Wiley 2020-01-01
Series:International Journal of Endocrinology
Online Access:http://dx.doi.org/10.1155/2020/8879085
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1832546941887578112
author Xia Sheng
Guo-Hui Xiong
Peng-Fei Yu
Jian-Ping Liu
author_facet Xia Sheng
Guo-Hui Xiong
Peng-Fei Yu
Jian-Ping Liu
author_sort Xia Sheng
collection DOAJ
description Background. In recent years, the time of blood glucose within the target range is a new research hotspot in blood glucose management. TIR is expected to be a novel indicator for evaluating the efficacy of glycemic control and predicting diabetic complications. However, its relationship with diabetic complications has not been fully elucidated. Objective. To explore the relationship between time in range (TIR) and glycosylated hemoglobin (HbA1C) through the information big data management platform. Possible association between TIR and diabetic microvascular complications (retinopathy, nephropathy, and neuropathy) was investigated, attempting to provide theoretical basis for the clinical application of TIR and to explore the TIR control scope suitable for diabetic patients. Methods. A total of 5,644 type 2 diabetic patients hospitalized in the Department of Endocrinology, the Second Affiliated Hospital of Nanchang University, were selected from April 2017 to June 2020. Fingertip capillary blood glucose monitoring (FCGM) was monitored for a total of 455,664 times, and patients who are nondiabetic, pregnant, or with diabetic ketosis were excluded. Patients with 7 blood glucose points monitored for at least three consecutive days were selected as subjects in the study. 1,895 males and 1,513 females with diabetes were included, with an average age of (59.74 ± 13.40) years old and an average course of disease of 8.28 ± 7.11 years. The proportion of time in range (TIR) (70∼180 mg/dl) within the target range and the correlation between TIR and HbA1C were analyzed, as well as the relationship between TIR and the risk of diabetic complications. Results. (1) The average of TIR and HbA1C was 49.65 ± 23.36% and 8.92 ± 2.49%, respectively, and was linearly correlated. With the decrease of TIR, HbA1C increased significantly, and the difference was statistically significant (P<0.01, R2 = 0.458). The correlation coefficient of mean TIR with mean HbA1C was −0.626. (2) There were 836 patients diagnosed with diabetic nephropathy (DN). The difference of TIR value between DN and non-DN was significant (T = 2.250, P<0.05). Risk assessment showed the lower the TIR was, the higher the risk of DN was. TIR less than 40% was a risk factor for DN (OR = 1.249, 95% CI: 0.915–1.375). (3) There were 1,296 patients diagnosed with diabetic peripheral neuropathy (DPN). The difference of TIR value between DPN and non-DPN was significant (T = 3.844, P<0.01). TIR value less than 70% was a risk factor for DPN (OR = 1.030, 95% CI: 0.769–1.379). (4) There were 2,077 patients diagnosed with diabetic retinopathy (DR). The difference of TIR value between DPN and non-DPN was significant (T = 3.608, P<0.01). TIR value less than 50% was a risk factor for DR (OR = 1.092, 95% CI: 0.898–1.264). Summary. TIR may serve as a reference index for short-term blood glucose control, strongly reflecting the clinical blood glucose regulation and predicting the risk of diabetic microvascular complications.
format Article
id doaj-art-5793ebbc83134dfd92a0337421d363d5
institution Kabale University
issn 1687-8337
1687-8345
language English
publishDate 2020-01-01
publisher Wiley
record_format Article
series International Journal of Endocrinology
spelling doaj-art-5793ebbc83134dfd92a0337421d363d52025-02-03T06:46:27ZengWileyInternational Journal of Endocrinology1687-83371687-83452020-01-01202010.1155/2020/88790858879085The Correlation between Time in Range and Diabetic Microvascular Complications Utilizing Information Management PlatformXia Sheng0Guo-Hui Xiong1Peng-Fei Yu2Jian-Ping Liu3Department of Endocrinology, Third Affiliated Hospital, Nanchang University, Nanchang 330008, ChinaNanchang Hongdu Hospital of Traditional Chinese Medicine, Nanchang 330000, ChinaDepartment of Endocrinology, Second Affiliated Hospital, Nanchang University, Nanchang 330008, ChinaDepartment of Endocrinology, Second Affiliated Hospital, Nanchang University, Nanchang 330008, ChinaBackground. In recent years, the time of blood glucose within the target range is a new research hotspot in blood glucose management. TIR is expected to be a novel indicator for evaluating the efficacy of glycemic control and predicting diabetic complications. However, its relationship with diabetic complications has not been fully elucidated. Objective. To explore the relationship between time in range (TIR) and glycosylated hemoglobin (HbA1C) through the information big data management platform. Possible association between TIR and diabetic microvascular complications (retinopathy, nephropathy, and neuropathy) was investigated, attempting to provide theoretical basis for the clinical application of TIR and to explore the TIR control scope suitable for diabetic patients. Methods. A total of 5,644 type 2 diabetic patients hospitalized in the Department of Endocrinology, the Second Affiliated Hospital of Nanchang University, were selected from April 2017 to June 2020. Fingertip capillary blood glucose monitoring (FCGM) was monitored for a total of 455,664 times, and patients who are nondiabetic, pregnant, or with diabetic ketosis were excluded. Patients with 7 blood glucose points monitored for at least three consecutive days were selected as subjects in the study. 1,895 males and 1,513 females with diabetes were included, with an average age of (59.74 ± 13.40) years old and an average course of disease of 8.28 ± 7.11 years. The proportion of time in range (TIR) (70∼180 mg/dl) within the target range and the correlation between TIR and HbA1C were analyzed, as well as the relationship between TIR and the risk of diabetic complications. Results. (1) The average of TIR and HbA1C was 49.65 ± 23.36% and 8.92 ± 2.49%, respectively, and was linearly correlated. With the decrease of TIR, HbA1C increased significantly, and the difference was statistically significant (P<0.01, R2 = 0.458). The correlation coefficient of mean TIR with mean HbA1C was −0.626. (2) There were 836 patients diagnosed with diabetic nephropathy (DN). The difference of TIR value between DN and non-DN was significant (T = 2.250, P<0.05). Risk assessment showed the lower the TIR was, the higher the risk of DN was. TIR less than 40% was a risk factor for DN (OR = 1.249, 95% CI: 0.915–1.375). (3) There were 1,296 patients diagnosed with diabetic peripheral neuropathy (DPN). The difference of TIR value between DPN and non-DPN was significant (T = 3.844, P<0.01). TIR value less than 70% was a risk factor for DPN (OR = 1.030, 95% CI: 0.769–1.379). (4) There were 2,077 patients diagnosed with diabetic retinopathy (DR). The difference of TIR value between DPN and non-DPN was significant (T = 3.608, P<0.01). TIR value less than 50% was a risk factor for DR (OR = 1.092, 95% CI: 0.898–1.264). Summary. TIR may serve as a reference index for short-term blood glucose control, strongly reflecting the clinical blood glucose regulation and predicting the risk of diabetic microvascular complications.http://dx.doi.org/10.1155/2020/8879085
spellingShingle Xia Sheng
Guo-Hui Xiong
Peng-Fei Yu
Jian-Ping Liu
The Correlation between Time in Range and Diabetic Microvascular Complications Utilizing Information Management Platform
International Journal of Endocrinology
title The Correlation between Time in Range and Diabetic Microvascular Complications Utilizing Information Management Platform
title_full The Correlation between Time in Range and Diabetic Microvascular Complications Utilizing Information Management Platform
title_fullStr The Correlation between Time in Range and Diabetic Microvascular Complications Utilizing Information Management Platform
title_full_unstemmed The Correlation between Time in Range and Diabetic Microvascular Complications Utilizing Information Management Platform
title_short The Correlation between Time in Range and Diabetic Microvascular Complications Utilizing Information Management Platform
title_sort correlation between time in range and diabetic microvascular complications utilizing information management platform
url http://dx.doi.org/10.1155/2020/8879085
work_keys_str_mv AT xiasheng thecorrelationbetweentimeinrangeanddiabeticmicrovascularcomplicationsutilizinginformationmanagementplatform
AT guohuixiong thecorrelationbetweentimeinrangeanddiabeticmicrovascularcomplicationsutilizinginformationmanagementplatform
AT pengfeiyu thecorrelationbetweentimeinrangeanddiabeticmicrovascularcomplicationsutilizinginformationmanagementplatform
AT jianpingliu thecorrelationbetweentimeinrangeanddiabeticmicrovascularcomplicationsutilizinginformationmanagementplatform
AT xiasheng correlationbetweentimeinrangeanddiabeticmicrovascularcomplicationsutilizinginformationmanagementplatform
AT guohuixiong correlationbetweentimeinrangeanddiabeticmicrovascularcomplicationsutilizinginformationmanagementplatform
AT pengfeiyu correlationbetweentimeinrangeanddiabeticmicrovascularcomplicationsutilizinginformationmanagementplatform
AT jianpingliu correlationbetweentimeinrangeanddiabeticmicrovascularcomplicationsutilizinginformationmanagementplatform