Diagnostic Role of Colon Capsule Endoscopy in Patients with Optimal Colon Cleaning
Background. Colon capsule endoscopy (CCE) is a diagnostic test with relatively rare usage. In this study, we aimed to evaluate both the optimal cleaning regimen for CCE and the diagnostic value of test in the study group. Methods. A total of 62 patients were enrolled in this study. In the first step...
Saved in:
Main Authors: | , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Wiley
2016-01-01
|
Series: | Gastroenterology Research and Practice |
Online Access: | http://dx.doi.org/10.1155/2016/2738208 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
_version_ | 1832550213358714880 |
---|---|
author | Ümit Akyüz Yusuf Yılmaz Ali Tüzün İnce Bülent Kaya Cengiz Pata |
author_facet | Ümit Akyüz Yusuf Yılmaz Ali Tüzün İnce Bülent Kaya Cengiz Pata |
author_sort | Ümit Akyüz |
collection | DOAJ |
description | Background. Colon capsule endoscopy (CCE) is a diagnostic test with relatively rare usage. In this study, we aimed to evaluate both the optimal cleaning regimen for CCE and the diagnostic value of test in the study group. Methods. A total of 62 patients were enrolled in this study. In the first step, 3 different colon preparing regimens were given to 30 patients [Group A: 3 days of liquid diet, sodium phosphate (NaP) (90 mL), and NaP enema; Group B: 3 days of liquid diet, 4 L of polyethylene glycol (PEG), and metoclopramide; Group C: 3 days of liquid diet, 4 L of PEG, NaP (45 mL), and bisacodyl after capsule ingestion] (10 patients in each group). The other consecutive 32 patients were cleaned with the best regimen which was NaP + PEG and CCE was performed. The results of CCE were controlled with colonoscopy in 28 patients. Results. Group C had the highest cleaning score, compared with the other groups (2.2±0.4 versus 2.7±0.4 versus 3.7±0.4, p value =0.000). The CCE findings were as follows in 28 patients who were also examined with colonoscopy: polyp (range: 5–10 mm) in 6 patients, internal hemorrhoids in 3 patients, angiodysplasia in 1 patient, diverticula in 1 patient, and ulcerative colitis in 1 patient. The sensitivity, specificity, PPV, and NPV of CCE were 100%, 92%, 93%, and 100%, respectively. Conclusions. Low dosage NaP combined with PEG provides optimal bowel preparation for CCE. CCE appears to be a highly sensitive diagnostic modality for detecting colonic pathologies. |
format | Article |
id | doaj-art-569e0f8bdb434aa0b275055ca011081c |
institution | Kabale University |
issn | 1687-6121 1687-630X |
language | English |
publishDate | 2016-01-01 |
publisher | Wiley |
record_format | Article |
series | Gastroenterology Research and Practice |
spelling | doaj-art-569e0f8bdb434aa0b275055ca011081c2025-02-03T06:07:20ZengWileyGastroenterology Research and Practice1687-61211687-630X2016-01-01201610.1155/2016/27382082738208Diagnostic Role of Colon Capsule Endoscopy in Patients with Optimal Colon CleaningÜmit Akyüz0Yusuf Yılmaz1Ali Tüzün İnce2Bülent Kaya3Cengiz Pata4Department of Gastroenterology, Yeditepe University, Kozyatağı, 34752 Istanbul, TurkeyDepartment of Gastroenterology, Marmara University, Maltepe, 81090 Istanbul, TurkeyDepartment of Gastroenterology, Bezm-i Alem University, Fatih, 34590 Istanbul, TurkeyDepartment of General Surgery, Fatih Sultan Mehmet Training and Research Hospital, Ataşehir, 34752 Istanbul, TurkeyDepartment of Gastroenterology, Yeditepe University, Kozyatağı, 34752 Istanbul, TurkeyBackground. Colon capsule endoscopy (CCE) is a diagnostic test with relatively rare usage. In this study, we aimed to evaluate both the optimal cleaning regimen for CCE and the diagnostic value of test in the study group. Methods. A total of 62 patients were enrolled in this study. In the first step, 3 different colon preparing regimens were given to 30 patients [Group A: 3 days of liquid diet, sodium phosphate (NaP) (90 mL), and NaP enema; Group B: 3 days of liquid diet, 4 L of polyethylene glycol (PEG), and metoclopramide; Group C: 3 days of liquid diet, 4 L of PEG, NaP (45 mL), and bisacodyl after capsule ingestion] (10 patients in each group). The other consecutive 32 patients were cleaned with the best regimen which was NaP + PEG and CCE was performed. The results of CCE were controlled with colonoscopy in 28 patients. Results. Group C had the highest cleaning score, compared with the other groups (2.2±0.4 versus 2.7±0.4 versus 3.7±0.4, p value =0.000). The CCE findings were as follows in 28 patients who were also examined with colonoscopy: polyp (range: 5–10 mm) in 6 patients, internal hemorrhoids in 3 patients, angiodysplasia in 1 patient, diverticula in 1 patient, and ulcerative colitis in 1 patient. The sensitivity, specificity, PPV, and NPV of CCE were 100%, 92%, 93%, and 100%, respectively. Conclusions. Low dosage NaP combined with PEG provides optimal bowel preparation for CCE. CCE appears to be a highly sensitive diagnostic modality for detecting colonic pathologies.http://dx.doi.org/10.1155/2016/2738208 |
spellingShingle | Ümit Akyüz Yusuf Yılmaz Ali Tüzün İnce Bülent Kaya Cengiz Pata Diagnostic Role of Colon Capsule Endoscopy in Patients with Optimal Colon Cleaning Gastroenterology Research and Practice |
title | Diagnostic Role of Colon Capsule Endoscopy in Patients with Optimal Colon Cleaning |
title_full | Diagnostic Role of Colon Capsule Endoscopy in Patients with Optimal Colon Cleaning |
title_fullStr | Diagnostic Role of Colon Capsule Endoscopy in Patients with Optimal Colon Cleaning |
title_full_unstemmed | Diagnostic Role of Colon Capsule Endoscopy in Patients with Optimal Colon Cleaning |
title_short | Diagnostic Role of Colon Capsule Endoscopy in Patients with Optimal Colon Cleaning |
title_sort | diagnostic role of colon capsule endoscopy in patients with optimal colon cleaning |
url | http://dx.doi.org/10.1155/2016/2738208 |
work_keys_str_mv | AT umitakyuz diagnosticroleofcoloncapsuleendoscopyinpatientswithoptimalcoloncleaning AT yusufyılmaz diagnosticroleofcoloncapsuleendoscopyinpatientswithoptimalcoloncleaning AT alituzunince diagnosticroleofcoloncapsuleendoscopyinpatientswithoptimalcoloncleaning AT bulentkaya diagnosticroleofcoloncapsuleendoscopyinpatientswithoptimalcoloncleaning AT cengizpata diagnosticroleofcoloncapsuleendoscopyinpatientswithoptimalcoloncleaning |