Diagnostic Role of Colon Capsule Endoscopy in Patients with Optimal Colon Cleaning

Background. Colon capsule endoscopy (CCE) is a diagnostic test with relatively rare usage. In this study, we aimed to evaluate both the optimal cleaning regimen for CCE and the diagnostic value of test in the study group. Methods. A total of 62 patients were enrolled in this study. In the first step...

Full description

Saved in:
Bibliographic Details
Main Authors: Ümit Akyüz, Yusuf Yılmaz, Ali Tüzün İnce, Bülent Kaya, Cengiz Pata
Format: Article
Language:English
Published: Wiley 2016-01-01
Series:Gastroenterology Research and Practice
Online Access:http://dx.doi.org/10.1155/2016/2738208
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1832550213358714880
author Ümit Akyüz
Yusuf Yılmaz
Ali Tüzün İnce
Bülent Kaya
Cengiz Pata
author_facet Ümit Akyüz
Yusuf Yılmaz
Ali Tüzün İnce
Bülent Kaya
Cengiz Pata
author_sort Ümit Akyüz
collection DOAJ
description Background. Colon capsule endoscopy (CCE) is a diagnostic test with relatively rare usage. In this study, we aimed to evaluate both the optimal cleaning regimen for CCE and the diagnostic value of test in the study group. Methods. A total of 62 patients were enrolled in this study. In the first step, 3 different colon preparing regimens were given to 30 patients [Group A: 3 days of liquid diet, sodium phosphate (NaP) (90 mL), and NaP enema; Group B: 3 days of liquid diet, 4 L of polyethylene glycol (PEG), and metoclopramide; Group C: 3 days of liquid diet, 4 L of PEG, NaP (45 mL), and bisacodyl after capsule ingestion] (10 patients in each group). The other consecutive 32 patients were cleaned with the best regimen which was NaP + PEG and CCE was performed. The results of CCE were controlled with colonoscopy in 28 patients. Results. Group C had the highest cleaning score, compared with the other groups (2.2±0.4 versus 2.7±0.4 versus 3.7±0.4, p value =0.000). The CCE findings were as follows in 28 patients who were also examined with colonoscopy: polyp (range: 5–10 mm) in 6 patients, internal hemorrhoids in 3 patients, angiodysplasia in 1 patient, diverticula in 1 patient, and ulcerative colitis in 1 patient. The sensitivity, specificity, PPV, and NPV of CCE were 100%, 92%, 93%, and 100%, respectively. Conclusions. Low dosage NaP combined with PEG provides optimal bowel preparation for CCE. CCE appears to be a highly sensitive diagnostic modality for detecting colonic pathologies.
format Article
id doaj-art-569e0f8bdb434aa0b275055ca011081c
institution Kabale University
issn 1687-6121
1687-630X
language English
publishDate 2016-01-01
publisher Wiley
record_format Article
series Gastroenterology Research and Practice
spelling doaj-art-569e0f8bdb434aa0b275055ca011081c2025-02-03T06:07:20ZengWileyGastroenterology Research and Practice1687-61211687-630X2016-01-01201610.1155/2016/27382082738208Diagnostic Role of Colon Capsule Endoscopy in Patients with Optimal Colon CleaningÜmit Akyüz0Yusuf Yılmaz1Ali Tüzün İnce2Bülent Kaya3Cengiz Pata4Department of Gastroenterology, Yeditepe University, Kozyatağı, 34752 Istanbul, TurkeyDepartment of Gastroenterology, Marmara University, Maltepe, 81090 Istanbul, TurkeyDepartment of Gastroenterology, Bezm-i Alem University, Fatih, 34590 Istanbul, TurkeyDepartment of General Surgery, Fatih Sultan Mehmet Training and Research Hospital, Ataşehir, 34752 Istanbul, TurkeyDepartment of Gastroenterology, Yeditepe University, Kozyatağı, 34752 Istanbul, TurkeyBackground. Colon capsule endoscopy (CCE) is a diagnostic test with relatively rare usage. In this study, we aimed to evaluate both the optimal cleaning regimen for CCE and the diagnostic value of test in the study group. Methods. A total of 62 patients were enrolled in this study. In the first step, 3 different colon preparing regimens were given to 30 patients [Group A: 3 days of liquid diet, sodium phosphate (NaP) (90 mL), and NaP enema; Group B: 3 days of liquid diet, 4 L of polyethylene glycol (PEG), and metoclopramide; Group C: 3 days of liquid diet, 4 L of PEG, NaP (45 mL), and bisacodyl after capsule ingestion] (10 patients in each group). The other consecutive 32 patients were cleaned with the best regimen which was NaP + PEG and CCE was performed. The results of CCE were controlled with colonoscopy in 28 patients. Results. Group C had the highest cleaning score, compared with the other groups (2.2±0.4 versus 2.7±0.4 versus 3.7±0.4, p value =0.000). The CCE findings were as follows in 28 patients who were also examined with colonoscopy: polyp (range: 5–10 mm) in 6 patients, internal hemorrhoids in 3 patients, angiodysplasia in 1 patient, diverticula in 1 patient, and ulcerative colitis in 1 patient. The sensitivity, specificity, PPV, and NPV of CCE were 100%, 92%, 93%, and 100%, respectively. Conclusions. Low dosage NaP combined with PEG provides optimal bowel preparation for CCE. CCE appears to be a highly sensitive diagnostic modality for detecting colonic pathologies.http://dx.doi.org/10.1155/2016/2738208
spellingShingle Ümit Akyüz
Yusuf Yılmaz
Ali Tüzün İnce
Bülent Kaya
Cengiz Pata
Diagnostic Role of Colon Capsule Endoscopy in Patients with Optimal Colon Cleaning
Gastroenterology Research and Practice
title Diagnostic Role of Colon Capsule Endoscopy in Patients with Optimal Colon Cleaning
title_full Diagnostic Role of Colon Capsule Endoscopy in Patients with Optimal Colon Cleaning
title_fullStr Diagnostic Role of Colon Capsule Endoscopy in Patients with Optimal Colon Cleaning
title_full_unstemmed Diagnostic Role of Colon Capsule Endoscopy in Patients with Optimal Colon Cleaning
title_short Diagnostic Role of Colon Capsule Endoscopy in Patients with Optimal Colon Cleaning
title_sort diagnostic role of colon capsule endoscopy in patients with optimal colon cleaning
url http://dx.doi.org/10.1155/2016/2738208
work_keys_str_mv AT umitakyuz diagnosticroleofcoloncapsuleendoscopyinpatientswithoptimalcoloncleaning
AT yusufyılmaz diagnosticroleofcoloncapsuleendoscopyinpatientswithoptimalcoloncleaning
AT alituzunince diagnosticroleofcoloncapsuleendoscopyinpatientswithoptimalcoloncleaning
AT bulentkaya diagnosticroleofcoloncapsuleendoscopyinpatientswithoptimalcoloncleaning
AT cengizpata diagnosticroleofcoloncapsuleendoscopyinpatientswithoptimalcoloncleaning