Clinical Impact of Preprocedural CT-Based 3D Computational Simulation of Left Atrial Appendage Occlusion with Amulet

Aims. Standard of care (SoC) device size selection with transoesophageal echocardiography (TOE) and computed tomography (CT) in LAAO can be challenging due to a certain degree of variability at both patient and device levels. The aim of this study was to prospectively evaluate the clinical impact of...

Full description

Saved in:
Bibliographic Details
Main Authors: Ian Buysschaert, Dries Viaene
Format: Article
Language:English
Published: Wiley 2021-01-01
Series:Journal of Interventional Cardiology
Online Access:http://dx.doi.org/10.1155/2021/9972228
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1832566275225681920
author Ian Buysschaert
Dries Viaene
author_facet Ian Buysschaert
Dries Viaene
author_sort Ian Buysschaert
collection DOAJ
description Aims. Standard of care (SoC) device size selection with transoesophageal echocardiography (TOE) and computed tomography (CT) in LAAO can be challenging due to a certain degree of variability at both patient and device levels. The aim of this study was to prospectively evaluate the clinical impact of 3D computational modelling software in the decision-making of left atrial appendage occlusion (LAAO) with Amplatzer Amulet. Methods and Results. SoC preprocedural assessments as well as CT-based 3D computational simulations (FEops) were performed in 15 consecutive patients scheduled for LAAO with Amulet. Preprocedural device size selection and degree of confidence were determined after SoC and after FEops-based assessments and compared to the implanted device. FEops-based preprocedural assessment correctly selected the implanted device size in 11 out of 15 patients (73.3%), compared to 7 patients (46.7%) for SoC-based assessment. In 4 patients (26.7%), FEops induced a change in device size initially selected by SoC. In the 7 patients (46.7%) in which FEops confirmed the SoC device size selection, the degree of confidence of the size selection increased from 6.4 ± 1.4 for SoC to 8.1 ± 0.7 for FEops. One patient (6.7%) could not be implanted for anatomical reason, as correctly identified by FEops. Conclusions. Preprocedural 3D computational simulation by FEops impacts Amulet size selection in LAAO compared to TOE and CT-based SoC assessment. Operators could consider FEops computational simulation in their preprocedural device size selection.
format Article
id doaj-art-53f94e6b611e45dd803c78b8108f9a3c
institution Kabale University
issn 0896-4327
1540-8183
language English
publishDate 2021-01-01
publisher Wiley
record_format Article
series Journal of Interventional Cardiology
spelling doaj-art-53f94e6b611e45dd803c78b8108f9a3c2025-02-03T01:04:34ZengWileyJournal of Interventional Cardiology0896-43271540-81832021-01-01202110.1155/2021/99722289972228Clinical Impact of Preprocedural CT-Based 3D Computational Simulation of Left Atrial Appendage Occlusion with AmuletIan Buysschaert0Dries Viaene1AZ Sint-Jan Brugge-Oostende AV, Ruddershove 10, Brugge 8000, BelgiumASZ, Merestraat 80, Aalst 9300, BelgiumAims. Standard of care (SoC) device size selection with transoesophageal echocardiography (TOE) and computed tomography (CT) in LAAO can be challenging due to a certain degree of variability at both patient and device levels. The aim of this study was to prospectively evaluate the clinical impact of 3D computational modelling software in the decision-making of left atrial appendage occlusion (LAAO) with Amplatzer Amulet. Methods and Results. SoC preprocedural assessments as well as CT-based 3D computational simulations (FEops) were performed in 15 consecutive patients scheduled for LAAO with Amulet. Preprocedural device size selection and degree of confidence were determined after SoC and after FEops-based assessments and compared to the implanted device. FEops-based preprocedural assessment correctly selected the implanted device size in 11 out of 15 patients (73.3%), compared to 7 patients (46.7%) for SoC-based assessment. In 4 patients (26.7%), FEops induced a change in device size initially selected by SoC. In the 7 patients (46.7%) in which FEops confirmed the SoC device size selection, the degree of confidence of the size selection increased from 6.4 ± 1.4 for SoC to 8.1 ± 0.7 for FEops. One patient (6.7%) could not be implanted for anatomical reason, as correctly identified by FEops. Conclusions. Preprocedural 3D computational simulation by FEops impacts Amulet size selection in LAAO compared to TOE and CT-based SoC assessment. Operators could consider FEops computational simulation in their preprocedural device size selection.http://dx.doi.org/10.1155/2021/9972228
spellingShingle Ian Buysschaert
Dries Viaene
Clinical Impact of Preprocedural CT-Based 3D Computational Simulation of Left Atrial Appendage Occlusion with Amulet
Journal of Interventional Cardiology
title Clinical Impact of Preprocedural CT-Based 3D Computational Simulation of Left Atrial Appendage Occlusion with Amulet
title_full Clinical Impact of Preprocedural CT-Based 3D Computational Simulation of Left Atrial Appendage Occlusion with Amulet
title_fullStr Clinical Impact of Preprocedural CT-Based 3D Computational Simulation of Left Atrial Appendage Occlusion with Amulet
title_full_unstemmed Clinical Impact of Preprocedural CT-Based 3D Computational Simulation of Left Atrial Appendage Occlusion with Amulet
title_short Clinical Impact of Preprocedural CT-Based 3D Computational Simulation of Left Atrial Appendage Occlusion with Amulet
title_sort clinical impact of preprocedural ct based 3d computational simulation of left atrial appendage occlusion with amulet
url http://dx.doi.org/10.1155/2021/9972228
work_keys_str_mv AT ianbuysschaert clinicalimpactofpreproceduralctbased3dcomputationalsimulationofleftatrialappendageocclusionwithamulet
AT driesviaene clinicalimpactofpreproceduralctbased3dcomputationalsimulationofleftatrialappendageocclusionwithamulet