Clinical Impact of Preprocedural CT-Based 3D Computational Simulation of Left Atrial Appendage Occlusion with Amulet
Aims. Standard of care (SoC) device size selection with transoesophageal echocardiography (TOE) and computed tomography (CT) in LAAO can be challenging due to a certain degree of variability at both patient and device levels. The aim of this study was to prospectively evaluate the clinical impact of...
Saved in:
Main Authors: | , |
---|---|
Format: | Article |
Language: | English |
Published: |
Wiley
2021-01-01
|
Series: | Journal of Interventional Cardiology |
Online Access: | http://dx.doi.org/10.1155/2021/9972228 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
_version_ | 1832566275225681920 |
---|---|
author | Ian Buysschaert Dries Viaene |
author_facet | Ian Buysschaert Dries Viaene |
author_sort | Ian Buysschaert |
collection | DOAJ |
description | Aims. Standard of care (SoC) device size selection with transoesophageal echocardiography (TOE) and computed tomography (CT) in LAAO can be challenging due to a certain degree of variability at both patient and device levels. The aim of this study was to prospectively evaluate the clinical impact of 3D computational modelling software in the decision-making of left atrial appendage occlusion (LAAO) with Amplatzer Amulet. Methods and Results. SoC preprocedural assessments as well as CT-based 3D computational simulations (FEops) were performed in 15 consecutive patients scheduled for LAAO with Amulet. Preprocedural device size selection and degree of confidence were determined after SoC and after FEops-based assessments and compared to the implanted device. FEops-based preprocedural assessment correctly selected the implanted device size in 11 out of 15 patients (73.3%), compared to 7 patients (46.7%) for SoC-based assessment. In 4 patients (26.7%), FEops induced a change in device size initially selected by SoC. In the 7 patients (46.7%) in which FEops confirmed the SoC device size selection, the degree of confidence of the size selection increased from 6.4 ± 1.4 for SoC to 8.1 ± 0.7 for FEops. One patient (6.7%) could not be implanted for anatomical reason, as correctly identified by FEops. Conclusions. Preprocedural 3D computational simulation by FEops impacts Amulet size selection in LAAO compared to TOE and CT-based SoC assessment. Operators could consider FEops computational simulation in their preprocedural device size selection. |
format | Article |
id | doaj-art-53f94e6b611e45dd803c78b8108f9a3c |
institution | Kabale University |
issn | 0896-4327 1540-8183 |
language | English |
publishDate | 2021-01-01 |
publisher | Wiley |
record_format | Article |
series | Journal of Interventional Cardiology |
spelling | doaj-art-53f94e6b611e45dd803c78b8108f9a3c2025-02-03T01:04:34ZengWileyJournal of Interventional Cardiology0896-43271540-81832021-01-01202110.1155/2021/99722289972228Clinical Impact of Preprocedural CT-Based 3D Computational Simulation of Left Atrial Appendage Occlusion with AmuletIan Buysschaert0Dries Viaene1AZ Sint-Jan Brugge-Oostende AV, Ruddershove 10, Brugge 8000, BelgiumASZ, Merestraat 80, Aalst 9300, BelgiumAims. Standard of care (SoC) device size selection with transoesophageal echocardiography (TOE) and computed tomography (CT) in LAAO can be challenging due to a certain degree of variability at both patient and device levels. The aim of this study was to prospectively evaluate the clinical impact of 3D computational modelling software in the decision-making of left atrial appendage occlusion (LAAO) with Amplatzer Amulet. Methods and Results. SoC preprocedural assessments as well as CT-based 3D computational simulations (FEops) were performed in 15 consecutive patients scheduled for LAAO with Amulet. Preprocedural device size selection and degree of confidence were determined after SoC and after FEops-based assessments and compared to the implanted device. FEops-based preprocedural assessment correctly selected the implanted device size in 11 out of 15 patients (73.3%), compared to 7 patients (46.7%) for SoC-based assessment. In 4 patients (26.7%), FEops induced a change in device size initially selected by SoC. In the 7 patients (46.7%) in which FEops confirmed the SoC device size selection, the degree of confidence of the size selection increased from 6.4 ± 1.4 for SoC to 8.1 ± 0.7 for FEops. One patient (6.7%) could not be implanted for anatomical reason, as correctly identified by FEops. Conclusions. Preprocedural 3D computational simulation by FEops impacts Amulet size selection in LAAO compared to TOE and CT-based SoC assessment. Operators could consider FEops computational simulation in their preprocedural device size selection.http://dx.doi.org/10.1155/2021/9972228 |
spellingShingle | Ian Buysschaert Dries Viaene Clinical Impact of Preprocedural CT-Based 3D Computational Simulation of Left Atrial Appendage Occlusion with Amulet Journal of Interventional Cardiology |
title | Clinical Impact of Preprocedural CT-Based 3D Computational Simulation of Left Atrial Appendage Occlusion with Amulet |
title_full | Clinical Impact of Preprocedural CT-Based 3D Computational Simulation of Left Atrial Appendage Occlusion with Amulet |
title_fullStr | Clinical Impact of Preprocedural CT-Based 3D Computational Simulation of Left Atrial Appendage Occlusion with Amulet |
title_full_unstemmed | Clinical Impact of Preprocedural CT-Based 3D Computational Simulation of Left Atrial Appendage Occlusion with Amulet |
title_short | Clinical Impact of Preprocedural CT-Based 3D Computational Simulation of Left Atrial Appendage Occlusion with Amulet |
title_sort | clinical impact of preprocedural ct based 3d computational simulation of left atrial appendage occlusion with amulet |
url | http://dx.doi.org/10.1155/2021/9972228 |
work_keys_str_mv | AT ianbuysschaert clinicalimpactofpreproceduralctbased3dcomputationalsimulationofleftatrialappendageocclusionwithamulet AT driesviaene clinicalimpactofpreproceduralctbased3dcomputationalsimulationofleftatrialappendageocclusionwithamulet |