THE METHOD OF DETERMINATION OF ERROR IN THE REFERENCE VALUE OF THE DOSE DURING THE LINEAR ACCELERATOR RADIATION OUTPUT CALIBRATION PROCEDURE. Part 3. The dependence of the radiation beam characteristics

To ensure the radiation protection of oncology patients is needed to provide the constancy of functional characteristics of the medical linear accelerators, which affect the accuracy of dose delivery. For this purpose, their quality control procedures are realized including calibration of radiation...

Full description

Saved in:
Bibliographic Details
Main Authors: E. V. Titovich, I. G. Tarutin, M. G. Kiselev
Format: Article
Language:English
Published: Belarusian National Technical University 2016-09-01
Series:Приборы и методы измерений
Subjects:
Online Access:https://pimi.bntu.by/jour/article/view/258
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1832543635365691392
author E. V. Titovich
I. G. Tarutin
M. G. Kiselev
author_facet E. V. Titovich
I. G. Tarutin
M. G. Kiselev
author_sort E. V. Titovich
collection DOAJ
description To ensure the radiation protection of oncology patients is needed to provide the constancy of functional characteristics of the medical linear accelerators, which affect the accuracy of dose delivery. For this purpose, their quality control procedures are realized including calibration of radiation output of the linac, so the error in determining the dose reference value during this procedure must not exceed 2 %. The aim is to develop a methodology for determining the error in determining this value, depending on the characteristics of the radiation beam. Dosimetric measurements of Trilogy S/N 3567 linac dose distributions have been carried out for achievement of the objectives, on the basis of which dose errors depending on the dose rate value, the accuracy of the beam quality and output factors determination, the symmetry and uniformity of the radiation field, the angular dependence of the linac radiation output were obtained. It was found that the greatest impact on the value of the error has the error in the output factors determination (up to 5.26 % for both photon energy). Dose errors caused by changing dose rate during treatment were different for two photon energies, and reached 1.6 % for 6 MeV and 1.4 % for 18 MeV. Dose errors caused by inaccuracies of the beam quality determination were different for two photon energies, and reached 1.1 % for 18 MeV and –0.3 % for 6 MeV. Errors caused by the remaining of the characteristic do not exceed 1 %. Thus, there is a possibility to express the results of periodic quality control of the linear accelerator in terms of dose and use them to conduct a comprehensive assessment of the possibility of clinical use of a linear accelerator for oncology patients irradiation on the basis of the calibration of radiation output.
format Article
id doaj-art-537a1ed67eb14cb99419a0c7bebcc7bb
institution Kabale University
issn 2220-9506
2414-0473
language English
publishDate 2016-09-01
publisher Belarusian National Technical University
record_format Article
series Приборы и методы измерений
spelling doaj-art-537a1ed67eb14cb99419a0c7bebcc7bb2025-02-03T11:37:43ZengBelarusian National Technical UniversityПриборы и методы измерений2220-95062414-04732016-09-017220321010.21122/2220-9506-2016-7-2-203-210247THE METHOD OF DETERMINATION OF ERROR IN THE REFERENCE VALUE OF THE DOSE DURING THE LINEAR ACCELERATOR RADIATION OUTPUT CALIBRATION PROCEDURE. Part 3. The dependence of the radiation beam characteristicsE. V. Titovich0I. G. Tarutin1M. G. Kiselev2N.N. Alexandrov National Cancer Centre of BelarusN.N. Alexandrov National Cancer Centre of BelarusBelarusian National Technical UniversityTo ensure the radiation protection of oncology patients is needed to provide the constancy of functional characteristics of the medical linear accelerators, which affect the accuracy of dose delivery. For this purpose, their quality control procedures are realized including calibration of radiation output of the linac, so the error in determining the dose reference value during this procedure must not exceed 2 %. The aim is to develop a methodology for determining the error in determining this value, depending on the characteristics of the radiation beam. Dosimetric measurements of Trilogy S/N 3567 linac dose distributions have been carried out for achievement of the objectives, on the basis of which dose errors depending on the dose rate value, the accuracy of the beam quality and output factors determination, the symmetry and uniformity of the radiation field, the angular dependence of the linac radiation output were obtained. It was found that the greatest impact on the value of the error has the error in the output factors determination (up to 5.26 % for both photon energy). Dose errors caused by changing dose rate during treatment were different for two photon energies, and reached 1.6 % for 6 MeV and 1.4 % for 18 MeV. Dose errors caused by inaccuracies of the beam quality determination were different for two photon energies, and reached 1.1 % for 18 MeV and –0.3 % for 6 MeV. Errors caused by the remaining of the characteristic do not exceed 1 %. Thus, there is a possibility to express the results of periodic quality control of the linear accelerator in terms of dose and use them to conduct a comprehensive assessment of the possibility of clinical use of a linear accelerator for oncology patients irradiation on the basis of the calibration of radiation output.https://pimi.bntu.by/jour/article/view/258linear accelerator radiation output calibrationerror in the reference value of the absorbed doseradiation beam characteristics
spellingShingle E. V. Titovich
I. G. Tarutin
M. G. Kiselev
THE METHOD OF DETERMINATION OF ERROR IN THE REFERENCE VALUE OF THE DOSE DURING THE LINEAR ACCELERATOR RADIATION OUTPUT CALIBRATION PROCEDURE. Part 3. The dependence of the radiation beam characteristics
Приборы и методы измерений
linear accelerator radiation output calibration
error in the reference value of the absorbed dose
radiation beam characteristics
title THE METHOD OF DETERMINATION OF ERROR IN THE REFERENCE VALUE OF THE DOSE DURING THE LINEAR ACCELERATOR RADIATION OUTPUT CALIBRATION PROCEDURE. Part 3. The dependence of the radiation beam characteristics
title_full THE METHOD OF DETERMINATION OF ERROR IN THE REFERENCE VALUE OF THE DOSE DURING THE LINEAR ACCELERATOR RADIATION OUTPUT CALIBRATION PROCEDURE. Part 3. The dependence of the radiation beam characteristics
title_fullStr THE METHOD OF DETERMINATION OF ERROR IN THE REFERENCE VALUE OF THE DOSE DURING THE LINEAR ACCELERATOR RADIATION OUTPUT CALIBRATION PROCEDURE. Part 3. The dependence of the radiation beam characteristics
title_full_unstemmed THE METHOD OF DETERMINATION OF ERROR IN THE REFERENCE VALUE OF THE DOSE DURING THE LINEAR ACCELERATOR RADIATION OUTPUT CALIBRATION PROCEDURE. Part 3. The dependence of the radiation beam characteristics
title_short THE METHOD OF DETERMINATION OF ERROR IN THE REFERENCE VALUE OF THE DOSE DURING THE LINEAR ACCELERATOR RADIATION OUTPUT CALIBRATION PROCEDURE. Part 3. The dependence of the radiation beam characteristics
title_sort method of determination of error in the reference value of the dose during the linear accelerator radiation output calibration procedure part 3 the dependence of the radiation beam characteristics
topic linear accelerator radiation output calibration
error in the reference value of the absorbed dose
radiation beam characteristics
url https://pimi.bntu.by/jour/article/view/258
work_keys_str_mv AT evtitovich themethodofdeterminationoferrorinthereferencevalueofthedoseduringthelinearacceleratorradiationoutputcalibrationprocedurepart3thedependenceoftheradiationbeamcharacteristics
AT igtarutin themethodofdeterminationoferrorinthereferencevalueofthedoseduringthelinearacceleratorradiationoutputcalibrationprocedurepart3thedependenceoftheradiationbeamcharacteristics
AT mgkiselev themethodofdeterminationoferrorinthereferencevalueofthedoseduringthelinearacceleratorradiationoutputcalibrationprocedurepart3thedependenceoftheradiationbeamcharacteristics
AT evtitovich methodofdeterminationoferrorinthereferencevalueofthedoseduringthelinearacceleratorradiationoutputcalibrationprocedurepart3thedependenceoftheradiationbeamcharacteristics
AT igtarutin methodofdeterminationoferrorinthereferencevalueofthedoseduringthelinearacceleratorradiationoutputcalibrationprocedurepart3thedependenceoftheradiationbeamcharacteristics
AT mgkiselev methodofdeterminationoferrorinthereferencevalueofthedoseduringthelinearacceleratorradiationoutputcalibrationprocedurepart3thedependenceoftheradiationbeamcharacteristics