Development and Validation of Gas Chromatography-Triple Quadrupole Mass Spectrometric Method for Quantitative Determination of Regulated Plasticizers in Medical Infusion Sets

A method for the quantitative determination of dibutyl phthalate (DBP), benzyl butyl phthalate (BBP), bis(2-ethylhexyl) adipate (DEHA), bis(2-ethylhexyl) phthalate (DEHP), di-n-octyl phthalate (DNOP), dioctyl terephthalate (DOTP), diisononyl phthalate (DINP), and diisodecyl phthalate (DIDP) in medic...

Full description

Saved in:
Bibliographic Details
Main Authors: So Hyeon Jeon, Yong Pyo Kim, Younglim Kho, Jeoung Hwa Shin, Won Hyun Ji, Yun Gyong Ahn
Format: Article
Language:English
Published: Wiley 2018-01-01
Series:Journal of Analytical Methods in Chemistry
Online Access:http://dx.doi.org/10.1155/2018/9470254
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1832561143779950592
author So Hyeon Jeon
Yong Pyo Kim
Younglim Kho
Jeoung Hwa Shin
Won Hyun Ji
Yun Gyong Ahn
author_facet So Hyeon Jeon
Yong Pyo Kim
Younglim Kho
Jeoung Hwa Shin
Won Hyun Ji
Yun Gyong Ahn
author_sort So Hyeon Jeon
collection DOAJ
description A method for the quantitative determination of dibutyl phthalate (DBP), benzyl butyl phthalate (BBP), bis(2-ethylhexyl) adipate (DEHA), bis(2-ethylhexyl) phthalate (DEHP), di-n-octyl phthalate (DNOP), dioctyl terephthalate (DOTP), diisononyl phthalate (DINP), and diisodecyl phthalate (DIDP) in medical infusion sets was developed and validated using gas chromatography coupled with triple quadrupole mass spectrometry (GC-MS/MS) in the multiple reaction monitoring (MRM) mode. Solvent extraction with polymer dissolution for sample preparation was employed prior to GC-MS/MS analysis. Average recoveries of the eight target analytes are typically in the range of 91.8–122% with the relative standard deviations of 1.8–17.8%. The limits of quantification (LOQs) of the analytical method were in the ranges of 54.1 to 76.3 ng/g. Analysis using GC-MS/MS provided reliable performance, as well as higher sensitivity and selectivity than GC-MS analysis, especially for the presence of minority plasticizers at different concentrations.
format Article
id doaj-art-53637bc4ba1f4123bfa363788e88e3da
institution Kabale University
issn 2090-8865
2090-8873
language English
publishDate 2018-01-01
publisher Wiley
record_format Article
series Journal of Analytical Methods in Chemistry
spelling doaj-art-53637bc4ba1f4123bfa363788e88e3da2025-02-03T01:25:50ZengWileyJournal of Analytical Methods in Chemistry2090-88652090-88732018-01-01201810.1155/2018/94702549470254Development and Validation of Gas Chromatography-Triple Quadrupole Mass Spectrometric Method for Quantitative Determination of Regulated Plasticizers in Medical Infusion SetsSo Hyeon Jeon0Yong Pyo Kim1Younglim Kho2Jeoung Hwa Shin3Won Hyun Ji4Yun Gyong Ahn5Western Seoul Center, Korea Basic Science Institute, Seoul 03759, Republic of KoreaDepartment of Chemical Engineering and Material Science, Ewha Womans University, Seoul 03760, Republic of KoreaDepartment of Health, Environment & Safety, Eulji University, Seongnam 13135, Republic of KoreaSeoul Center, Korea Basic Science Institute, Seoul 02841, Republic of KoreaInstitute of Mine Reclamation Technology, Mine Reclamation Corporation, Wonju 26464, Republic of KoreaWestern Seoul Center, Korea Basic Science Institute, Seoul 03759, Republic of KoreaA method for the quantitative determination of dibutyl phthalate (DBP), benzyl butyl phthalate (BBP), bis(2-ethylhexyl) adipate (DEHA), bis(2-ethylhexyl) phthalate (DEHP), di-n-octyl phthalate (DNOP), dioctyl terephthalate (DOTP), diisononyl phthalate (DINP), and diisodecyl phthalate (DIDP) in medical infusion sets was developed and validated using gas chromatography coupled with triple quadrupole mass spectrometry (GC-MS/MS) in the multiple reaction monitoring (MRM) mode. Solvent extraction with polymer dissolution for sample preparation was employed prior to GC-MS/MS analysis. Average recoveries of the eight target analytes are typically in the range of 91.8–122% with the relative standard deviations of 1.8–17.8%. The limits of quantification (LOQs) of the analytical method were in the ranges of 54.1 to 76.3 ng/g. Analysis using GC-MS/MS provided reliable performance, as well as higher sensitivity and selectivity than GC-MS analysis, especially for the presence of minority plasticizers at different concentrations.http://dx.doi.org/10.1155/2018/9470254
spellingShingle So Hyeon Jeon
Yong Pyo Kim
Younglim Kho
Jeoung Hwa Shin
Won Hyun Ji
Yun Gyong Ahn
Development and Validation of Gas Chromatography-Triple Quadrupole Mass Spectrometric Method for Quantitative Determination of Regulated Plasticizers in Medical Infusion Sets
Journal of Analytical Methods in Chemistry
title Development and Validation of Gas Chromatography-Triple Quadrupole Mass Spectrometric Method for Quantitative Determination of Regulated Plasticizers in Medical Infusion Sets
title_full Development and Validation of Gas Chromatography-Triple Quadrupole Mass Spectrometric Method for Quantitative Determination of Regulated Plasticizers in Medical Infusion Sets
title_fullStr Development and Validation of Gas Chromatography-Triple Quadrupole Mass Spectrometric Method for Quantitative Determination of Regulated Plasticizers in Medical Infusion Sets
title_full_unstemmed Development and Validation of Gas Chromatography-Triple Quadrupole Mass Spectrometric Method for Quantitative Determination of Regulated Plasticizers in Medical Infusion Sets
title_short Development and Validation of Gas Chromatography-Triple Quadrupole Mass Spectrometric Method for Quantitative Determination of Regulated Plasticizers in Medical Infusion Sets
title_sort development and validation of gas chromatography triple quadrupole mass spectrometric method for quantitative determination of regulated plasticizers in medical infusion sets
url http://dx.doi.org/10.1155/2018/9470254
work_keys_str_mv AT sohyeonjeon developmentandvalidationofgaschromatographytriplequadrupolemassspectrometricmethodforquantitativedeterminationofregulatedplasticizersinmedicalinfusionsets
AT yongpyokim developmentandvalidationofgaschromatographytriplequadrupolemassspectrometricmethodforquantitativedeterminationofregulatedplasticizersinmedicalinfusionsets
AT younglimkho developmentandvalidationofgaschromatographytriplequadrupolemassspectrometricmethodforquantitativedeterminationofregulatedplasticizersinmedicalinfusionsets
AT jeounghwashin developmentandvalidationofgaschromatographytriplequadrupolemassspectrometricmethodforquantitativedeterminationofregulatedplasticizersinmedicalinfusionsets
AT wonhyunji developmentandvalidationofgaschromatographytriplequadrupolemassspectrometricmethodforquantitativedeterminationofregulatedplasticizersinmedicalinfusionsets
AT yungyongahn developmentandvalidationofgaschromatographytriplequadrupolemassspectrometricmethodforquantitativedeterminationofregulatedplasticizersinmedicalinfusionsets