Analysis of the Law of Joint Deformation for Grouted Mortise-Tenon Joint
This paper analyzes the law of joint deformation of grouted mortise-tenon joint with 1 : 1 prototype test in key working direction types under 38 working conditions of different joint types, tenon lengths, grouting ranges, grouting materials, and loading combinations for the prefabricated metro stat...
Saved in:
Main Authors: | , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Wiley
2022-01-01
|
Series: | Advances in Civil Engineering |
Online Access: | http://dx.doi.org/10.1155/2022/2909993 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
_version_ | 1832565583772647424 |
---|---|
author | Xiuren Yang Fang Lin Meiqun Huang |
author_facet | Xiuren Yang Fang Lin Meiqun Huang |
author_sort | Xiuren Yang |
collection | DOAJ |
description | This paper analyzes the law of joint deformation of grouted mortise-tenon joint with 1 : 1 prototype test in key working direction types under 38 working conditions of different joint types, tenon lengths, grouting ranges, grouting materials, and loading combinations for the prefabricated metro station. The deformation performance of the joint has also been compared. In addition, finite element models have been built, and the joint deformation stages are discussed. The influences on the law of joint deformation of different influencing factors have been discovered. The deformation development stages and the main deformation laws of each stage of the joints have also been obtained. Moreover, this paper also compares and analyzes the field test results and experimental results. The monitoring results show that the safety margin of joint deformation is sufficient during the whole construction process from the assembly to the completion of the station. The research results have great values for the joint design and calculation for the prefabricated metro station structure. |
format | Article |
id | doaj-art-522190560f20401585034c47f41be5ef |
institution | Kabale University |
issn | 1687-8094 |
language | English |
publishDate | 2022-01-01 |
publisher | Wiley |
record_format | Article |
series | Advances in Civil Engineering |
spelling | doaj-art-522190560f20401585034c47f41be5ef2025-02-03T01:07:10ZengWileyAdvances in Civil Engineering1687-80942022-01-01202210.1155/2022/2909993Analysis of the Law of Joint Deformation for Grouted Mortise-Tenon JointXiuren Yang0Fang Lin1Meiqun Huang2Beijing Urban Construction Design and Development Group Co., Ltd.,Beijing Urban Construction Design and Development Group Co., Ltd.,Beijing Urban Construction Design and Development Group Co., Ltd.,This paper analyzes the law of joint deformation of grouted mortise-tenon joint with 1 : 1 prototype test in key working direction types under 38 working conditions of different joint types, tenon lengths, grouting ranges, grouting materials, and loading combinations for the prefabricated metro station. The deformation performance of the joint has also been compared. In addition, finite element models have been built, and the joint deformation stages are discussed. The influences on the law of joint deformation of different influencing factors have been discovered. The deformation development stages and the main deformation laws of each stage of the joints have also been obtained. Moreover, this paper also compares and analyzes the field test results and experimental results. The monitoring results show that the safety margin of joint deformation is sufficient during the whole construction process from the assembly to the completion of the station. The research results have great values for the joint design and calculation for the prefabricated metro station structure.http://dx.doi.org/10.1155/2022/2909993 |
spellingShingle | Xiuren Yang Fang Lin Meiqun Huang Analysis of the Law of Joint Deformation for Grouted Mortise-Tenon Joint Advances in Civil Engineering |
title | Analysis of the Law of Joint Deformation for Grouted Mortise-Tenon Joint |
title_full | Analysis of the Law of Joint Deformation for Grouted Mortise-Tenon Joint |
title_fullStr | Analysis of the Law of Joint Deformation for Grouted Mortise-Tenon Joint |
title_full_unstemmed | Analysis of the Law of Joint Deformation for Grouted Mortise-Tenon Joint |
title_short | Analysis of the Law of Joint Deformation for Grouted Mortise-Tenon Joint |
title_sort | analysis of the law of joint deformation for grouted mortise tenon joint |
url | http://dx.doi.org/10.1155/2022/2909993 |
work_keys_str_mv | AT xiurenyang analysisofthelawofjointdeformationforgroutedmortisetenonjoint AT fanglin analysisofthelawofjointdeformationforgroutedmortisetenonjoint AT meiqunhuang analysisofthelawofjointdeformationforgroutedmortisetenonjoint |